ATI Hydrocarbon Sensor (00-1516)

Smart Sensor Modules:

Plug-in sensors store calibration data, allowing sensors to be calibrated separately from the transmitter.  This allows bench calibration (or factory calibration) of sensors to reduce the necessity for carrying calibration gas to the gas detector.

Hydrocarbon Information

$465.00

The ATI Hydrocarbon (HC) sensor can detect a wide variety of hydrocarbon gasses:

Ethylene ( C2H4)
Propylene (C3H6)
Propylene Oxide (C3H6O)
Vinyl Chloride (C2H3Cl)
Acetaldehyde (C2H4O)
Butadiene (C4H6)
Vinyl Acetate (C4H6O2)
Epichlorhydrin  (C3H5ClO)
Diethyl Ether (C4H10O)
Methylmethacrylate (C5H8O2)
Styrene (C8H8)
Tetrahydrofuran (C4H8O)

Accuracy ± 5% of value
Standard Range 0-1000 ppm
Minimum Range 0-50 ppm
Maximum Range 0-500 ppm

This sensor will be calibrated for detection of your choice of calibrations.  please call for details on custom calibration ranges.

Sensor modules are ATI's newest miniaturized smart sensor modules.  Each sensor module is actually a sensor, amplifier, and memory module in one compact package.  Because of this design, sensor modules can be calibrated independently and simply plugged into any detector for immediate use.  When installed in a detector, calibration data is loading into the microprocessor so that no adjustments are needed.  The result is that a detector can, for example, go from phosgene measurement to ammonia measurement in less than one minute.

Using the optional sensor keeper allows up to 4 sensors to be powered by the internal sensor keeper battery and keep sensors ready for use.  This ensures maximum accuracy in the shortest time frame possible.

The ATI Smart Sensors are compatible with the D-16, F-12is, F-12D, and D-12 gas detectors.

 

All smart sensors are constructed of glass filled polycarbonate and use an electrochemical cell for gas detection.

Hydrocarbon Information

More Information
Manufacturer ATI
Call For Price No
Gas Hydrocarbon (HC)
Sensor Type Electrochemical Cell
Range 0-1000 ppm
Maximum Exposure 0-1000 ppm
Minimum Detection Limit 0-50 ppm
Accuracy ± 5% of value
Resolution 1 ppm
Standard Range 0-1000 ppm
Minimum Range 0-50 ppm
Maximum Range 0-500 ppm
Monitor sensor fits D16 / C16 / F12 / D12
Sensitivity 1% of sensor module range
Operational Temperature Range -25º to +55ºC
Operational RH Range 0-95% Non-condensing
Warranty 1 Year