465H Ozone Analyzer

High range ozone analyzer measures ozone up to 25% by weight, or 400 g/m3.  Great for measuring output of an ozone generator, or real time process measurement of ozone from the ozone generator. This unit comes in the NEMA configuration only. 

 

$8,130.00
60 Day Lead Time per the Manufacturer

The Model 465H is a microprocessor based high concentration ozone monitor for measuring ozone in process gas streams in water treatment, food processing, and research applications. The 465H has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465H is available in a 19” rack mount or NEMA 4X wall mount enclosure.

The sensor module contained in the Model 465H uses detectors which have a very narrow band of spectral sensitivity, eliminating the need for UV band pass filters which are subject to deterioration by UV or humidity. Two detectors are used: one for the ozone measurement, and the other to compensate for changes in UV lamp intensity. This unique design provides a sensor which will operate for extended periods without calibration or maintenance.

Built-in diagnostics provide warning signals in case operating parameters are out of range. Test values can be viewed while the Model 465H is operating. These displays, warnings, and self-diagnostics, along with the modular design, allow maximum uptime. In addition, any function that can be set or monitored from the front panel can be remotely set or viewed through the bidirectional RS-232 port.

Features:

  • Standard one year warranty
  • UV Absorption Method
  • Microprocessor controlled
  • Menu driven software
  • Ranges 0-5 to 0-25% w/w
  • Built-in diagnostics
  • Self-check warning alarms
  • Fast response times
  • Minimal zero drift
  • Programmable auto-zero function included
  • Programmable concentration alarms
  • Temperature and pressure compensation (standard)
  • Optional Ethernet



Specifications:
Measuring principle: UV Absorption (Beer Lambert Law)
Ranges: 0-5% w/w to 0-25% w/w
0-100g/Nm3 to 0-400g/Nm3
Units: % w/w, g/Nm3
Precision / Repeatability: ± 0.5% of full scale
Display resolution: 0.01 % w/w, 0.1 g/Nm3
Response time: < 5 seconds to 95%
Temperature compensation: Standard
Pressure compensation: Standard
Gas flow rate: 0.2 – 2.0 LPM
Operating Temperature Range: 5 - 45° C
Dimensions (HxWxD): Rack Mount – 5.22" (133 mm) x 
19" (483 mm) x 15.3" (388 mm)
NEMA 4X – 16.01" (407 mm) x
15.77" (401 mm) x 8.02" (204 mm)
Weight: Rack Mount – 13.6 lbs (6.17 kg)
NEMA 4X – 15.35 lbs (6.9 kg)
Power: 100 - 240VAC, 50/60 Hz, 1.1A
Analog output (Bi-polar): 5V or 4-20mA or isolated output
Status outputs: System OK, Invalid Reading, UV Lamp Fault
RS-232: 57.6 Kbaud, DB-9 connector
Approvals: CE

 

Downloads:

API Model 465H Brochure

API Model 465H Manual

M465H Replacement Parts
Part Description Part Number
Ultra Violet Lamp 030700000
UV Detector Assembly 025710100
Spring HW0000020
Sapphire Window OP0000019
Pressure Sensor SW0000029
Power Supply 60W PS0000042
Ozone Scrubber Assembly 048990200
O-Ring 2-022 OR0000076
O-Ring 2-018 OR0000075
O-Ring 2-014 OR0000074
Maintenance Kit 028510000
High Concentration Scrubber 048990300
Front Panel Board Single Channel 053130400
Critical Flow Orifice 000940800
Auto Zero Valve 052740000
More Information
Manufacturer Teledyne API
Call For Price No
4-20 mA Output Yes
Relays 2 Relays
Maximum Range 0-500 ppm
Minimum Range 0-1 ppm
Accuracy ± 0.5% of full scale
Min, Max, Avg No
Voltage Output 0-5 V
Power Requirements 100 - 240VAC, 50/60 Hz
Datalogging No
Rechargeable Yes
Warranty 1 Year
Audible Alarm Yes
Calibration Annually
Range 0-5% w/w to 0-25% w/w 0-100g/Nm3 to 0-400g/Nm3
Unit Features

-Self Check Warning Alarms

-Quick Response Times

-UV Absorption Methods

-Minimal Zero Drift

 

Sensor Range

0-25% w/w or 0-400 g/Nm3

Resolution 0.01 %
Sensor Range

0-25% w/w

0-400 g/m3