Mercury SafeAir Badge (382005-50)

SafeAir chemical detection badges are a visual indication badge that alerts you with a color changing exclamation mark when there is a specific chemical hazard.

Quantity = 50 badges  *clips are NOT included*

Note: we are not able to ship these badges outside of the US

Mercury Information

$257.00

Color change for Mercury is from white to purple.

The SafeAir Mercury Dual Level badge may be used for personal or area monitoring for exposure time from 15 minutes to 48 hours.

 

Introduction

Mercury is a silver-white, heavy, mobile, liquid metal with no specific odor. It is readily absorbed through the skin, the gastrointestinal tract and the respiratory tract. Chronic exposure may cause inflammation of the mouth and gums, kidney damage, muscle tremors, depression, and nervousness. Mercury spills and heated mercury are particularly hazardous. OSHA and NIOSH exposure limit for mercury is 0.1 mg/m3 (ceiling).

Mercury is used in barometers, thermometers, hydrometers, pyrometers, and in mercury arc lamps producing ultraviolet rays. It is also used in pharmaceuticals, agricultural chemicals, and antifouling paints

 

Principle of Operation

The SafeAir mercury badge is a monitoring system designed to indicate the presence of mercury at concentrations below the permissible exposure limit. The SafeAir mercury badge detects the presence of mercury by forming a color change in the shape of an exclamation mark inside the triangle. This indication is produced by a color-forming reaction which occurs when mercury reacts with a flat indicator layer

 SafeAir chemical detection badges are a visual indication badge that alerts you with a color changing exclamation mark when there is a specific chemical hazard.

 

Operating Instructions

1. Remove the pouch from the refrigerator and allow it to warm to room temperature.

2. Remove the badge from its protective pouch.

3. For personnel monitoring, attach the badge near the user’s breathing zone (i.e. the collar) with the front side exposed to the surrounding atmosphere.

4. For area monitoring, attach the badge to a stand and mount in a centralized area with the front side exposed to the surrounding atmosphere.

5. The exclamation mark appears within the triangle when mercury is present. Please note that an exclamation mark may appear on either the back or the front and the back of the badge.

6. To obtain the average concentration, divide the exposure dose (mg/m3 ∙hr) by the exposure time in hours (hr).

 

Storage

The ChromAir mercury monitor should be refrigerated in its sealed bag at all times.

 

Sampling Parameters

  Front

Back

Color Change

white to purple

Exposure level

0.25 mg/m3 ∙ hr

0.08 mg/m3 ∙ hr

Minimum detectable limit (8 hours)

0.031 mg/m3

0.01 mg/m3

Maximum recommended sampling time

48 hours

Minimum recommended sampling time

15 minutes

Relative humidity range

10% - 86%

Face velocity range

10 - 150 cm/sec

Temperature range

50ºF - 104ºF

Light effect - UV (direct sunlight)

no effect

Light effect - visible

no effect

Color stability

2 days

Refrigerated shelf life

1 year

 

Downloads

382005 Manual

Mercury Information

More Information
Manufacturer Morphix
Call For Price No
Gas Mercury
Operational Temperature Range 50°F - 104°F
Operational RH Range 10% - 86%
Maximum Exposure 0.25 mg/m3-hr
Audible Alarm No
Calibration N/A
Sensor Life 48 Hours
Range 0.031-0.25 mg/m3-hr
Sensor Range

0.031-0.25 mg/m3-hr