K-7904 Peracetic Acid

K-7904 Peracetic Acid CHEMets Kit was designed to obtain Peracetic Acid levels from 0-1 ppm and 0-5 ppm

Replacement ampoules for the K-7904 Test Kit can be found here.

Peracetic Acid Information

$77.50
2-5 Business Days

Why Choose CHEMetrics Chemets kits?

CHEMetrics Chemets self-filing reagent ampoules are a great way to test for dissolved substances in liquids. These visual test kits allow you to obtain results by measuring the color of the sample according to the color comparators provided with the kit. This unique method allows you to attain results quickly and accurately with minimal contact with potentially hazardous materials.

Safe and Reliable Results:

While traditional methods often require multiple steps and thorough preparation, these test kits allow you to obtain dependable results with a few simple steps. By simplifying the testing method, Chemets test kits reduce the potential for operator error. Additionally, each of the ampoules contained in the test kits is vacuum sealed which helps eliminate the problem of obtaining inaccurate results from stale or unstable reagents. These reagents are stored right in the tip of each ampoule and sealed in glass, thereby minimizing direct contact with the chemicals.

What's Included:

     -30 self-filling Ampoules

     -low and high-range comparators 

     -1 25 mL Sample Cup

     -Activator Solution

     -Instruction Manual

 

Method:

The K-7904 Peracetic Acid Kit was designed to accurately measure the levels of Peracetic Acid in water from 0-1 ppm and 0-5 ppm. K-7904 uses the DPD Method. In the DPD Method, hydrogen peroxide reacts with DPD (N, N-diethyl-p-phenylenediamine) in the presence of potassium iodide and ammonium molybdate to form a pink color. Various oxidizing agents such as halogens, ozone, and peracetic acid will produce high test results. Results are expressed as ppm (mg/L) H2O2.

 

1. Fill the sample cup to the 25 mL mark with the sample to be tested. Add 5 drops of Activator Solution. Stir to mix the contents of the cup. 2. immediately place the ampoule tip-first into the sample cup. Snap the tip and the ampoule will automatically fill.
3. To mix the ampoule, tilt it from side to side, allowing the bubble to travel from end to end. 4. Dry the ampoule and wait 1 minute for color development.
5. Place the ampoule into the center of the round comparator and hold it toward a source of light, viewing from the bottom. Rotate the comparator until the color below the ampoule shows the closest match. 6. For higher concentrations, use flat comparator. Place the ampoule between the color standards, moving it along the comparator until you can determine the closest match.

For more detailed instructions, see the link at the bottom of the page.

 

Vacu-Vials
Product Number Method   Range
I2020 DPD   0-5.0 ppm
K1913 DPD   0-5.0 ppm
Chemets Kits
Product Number Method MDL Range
K7904 DPD 0.05ppm 0-1 & 0-5 ppm
Vacuettes
Product Number Method MDL Range
K7904A DPD 7 ppm 0-70 & 0-300 ppm
K7904B DPD 15 ppm 0-130 & 0-600 ppm
K7904C DPD 120 ppm 0-1200 & 0-6000 ppm
K7909D DPD 3 ppm 0-30 & 0-150 ppm

Vacu-VialsProduct NumberMethod

Downloads:

K-7904 Instructions

Safety Data Sheet

Peracetic Acid Tech Sheet

Peracetic Acid Information

 

 

More Information
Manufacturer CHEMetrics
Call For Price No
Gas Peracetic Acid
4-20 mA Output No
Voltage Output None
Power Requirements 4 AAA Batteries
Datalogging No
Warranty 1 Year
Range 0-1 ppm and 0-5 ppm