SM-7 SM-EC

NEW Electrochemical sensor,0-20ppm or 0-50ppm range, RS-232 transmitting module, 10% or better accuracy, humidity compensated, eliminates most VOC interferences,  pre-calibrated field replaceable sensor.

$695.00

The SM-7 Sensor can be used as a stand-alone oem solution with RS-232 communications, or used as the sensor module with the OS-4 or OS-6 Ozone Monitors.

The SM-7 boasts the SM-EC Electrochemical sensor with a range of 0-20ppm or 0-50 ppm.  This sensor will be more accurate, and work better in high humidity areas than the standard SM-X sensor used in the SM-6 Sensor Module.  This is a great option  for food storage and other industrial applications where cross-sensitivity to ozone is a concern from other gasses in the area.

For calibrating your SM-7, you should replace the sensor annually.

 

Typical Applications:

     -Laundries using ozone.

     -Large noisy factory environments.

     -Casinos and other ozonated public areas.

     -Agricultural storage areas.

     -Farms.

     -Food processing plants.

 

Features:

     -25ppb sensitivity with 5ppb resolution.

     -Wide operating range (.02-50ppm).

     -Electrochemical Sensor

     -Wide detection range

     -Low Power

     -Low Maintenance

     -Uses easily available 8-24 VDC power.

     -Small enough to mount almost anywhere.

 

The SM-EC is an electrochemical ozone sensor module for use with our OS-6 digital instrument. This new technology from Eco Sensors provides accurate ppb-level detection and resolution over a wide (.2-50 ppm) concentration range. The sensor module is compensated for temperature and humidity effects, with little to no cross sensitivity to VOC’s. The SM-EC makes our digital instruments more accurate at both ppb and high ppm levels of ozone, enabling improved monitoring and control for our users.

 

 

Links:

EcoSensors Calibration information

General Calibration Information

 

More Information
Manufacturer Eco Sensors
Call For Price No
Gas Ozone (O3)
Resolution 0.01 ppm
Integrated Relays No
Response Time 1 second
Sensor type Electrochemical
Sampling Method Diffusion
Alarms no
Operational Temperature Range 35 - 100 deg F
Operational RH Range 0 - 85% RH
Power Requirements 12 VDC
Field Replaceable Battery No
Warranty 1 Year
Audible Alarm No
Calibration Replace with Pre-Calibrated Sensor Annually
Sensor Life 1 Year
Range 0-20ppm or 0-50 ppm
Unit Features

-RS-232 Transmitter

-Field Replaceable Sensor

Sensor Range

0-20 ppm

0-50 ppm

Sensor Range

0-20 ppm (O3)

0-50 ppm (O3)

Write Your Own Review
You're reviewing:SM-7 SM-EC
Your Rating
We found other products you might like!
Loading...