{"id":121,"date":"2021-04-20T08:30:00","date_gmt":"2021-04-20T13:30:00","guid":{"rendered":"http:\/\/www.gas-sensing.com\/news\/?p=121"},"modified":"2021-04-19T14:06:32","modified_gmt":"2021-04-19T19:06:32","slug":"electrochemical-vs-heated-metal-oxide-sensors","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/electrochemical-vs-heated-metal-oxide-sensors\/","title":{"rendered":"Electrochemical vs Heated Metal Oxide Sensors"},"content":{"rendered":"<p style=\"text-align: left\">An interesting article from Aeroqual on the differences between<a href=\"https:\/\/www.gas-sensing.com\/replacement-sensors.html?limit=all&amp;sensor_type=162\"> Electrochemical (EC)<\/a> and <a href=\"https:\/\/www.gas-sensing.com\/replacement-sensors.html?limit=all&amp;sensor_type=164\">Heated Metal Oxide Sensors (HMOS)<\/a> for measuring ozone.<\/p>\n<h2 style=\"text-align: left\"><span style=\"color: #3366ff\">ELECTROCHEMICAL (EC) OZONE SENSORS<\/span><\/h2>\n<figure id=\"attachment_124\" aria-describedby=\"caption-attachment-124\" style=\"width: 300px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.gas-sensing.com\/replacement-sensors.html?limit=all&amp;sensor_type=162\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-124\" src=\"https:\/\/www.gas-sensing.com\/wp\/wp-content\/uploads\/sites\/2\/2017\/02\/Replacement-Sensor-2-300x192.png\" alt=\"ATI A14\/A11 Replacement Sensor\" width=\"300\" height=\"192\" srcset=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Replacement-Sensor-2-300x192.png 300w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Replacement-Sensor-2-768x492.png 768w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Replacement-Sensor-2-624x400.png 624w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Replacement-Sensor-2.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-124\" class=\"wp-caption-text\">ATI A14\/A11 Replacement Sensor (Electrochemical)<\/figcaption><\/figure>\n<p style=\"text-align: left\">In an electrochemical sensor, ozone gas diffuses across a porous membrane into a cell containing electrolyte and electrodes. When ozone comes into contact with the electrolyte, a change in electrochemical potential occurs between the electrodes causing electrons to flow.<\/p>\n<p style=\"text-align: left\">In zero air, little or no electron flow occurs. As the presence of ozone increases, the electrical signal increases proportionally. The sensor interprets this signal and outputs the ozone concentration in ppm (parts per million) or ppb (parts per billion).<span id=\"more-7463\"><\/span><\/p>\n<h3 style=\"text-align: left\"><span style=\"color: #3366ff\">Strengths<\/span><\/h3>\n<ul style=\"text-align: left\">\n<li>Linear Response<\/li>\n<li>Good repeat-ability and accuracy<\/li>\n<li>Fast response time \u2013 1-2 Seconds<\/li>\n<li>Low power consumption<\/li>\n<li>Able to measure up to 20 ppm<\/li>\n<li>Limited cross interference from VOCs<\/li>\n<\/ul>\n<h3><span style=\"color: #3366ff\">Weaknesses<\/span><\/h3>\n<ul style=\"text-align: left\">\n<li>Humidity can affect sensor readings<\/li>\n<li>Changes in temperature can affect sensor readings<\/li>\n<li>Sensitive to EMF\/RFI<\/li>\n<li>Limited sensor life (often max of 12-18 months)<\/li>\n<li>Sensors age even when in storage<\/li>\n<li>Reduced accuracy at low ozone levels (below 0.1 ppm)<\/li>\n<li>Almost 100% cross sensitive to NO2<\/li>\n<\/ul>\n<h3><span style=\"color: #3366ff\">Applications<\/span><\/h3>\n<ul>\n<li>Detecting ozone leaks<\/li>\n<li>Health and safety monitoring (above 0.1 ppm)<\/li>\n<li>Controlling alarms, ozone generators etc (above 0.1 ppm)<\/li>\n<\/ul>\n<h2><span style=\"color: #3366ff\">HEATED METAL OXIDE SENSORS (HMOS)<\/span><\/h2>\n<figure id=\"attachment_125\" aria-describedby=\"caption-attachment-125\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.gas-sensing.com\/replacement-sensors.html?limit=all&amp;sensor_type=164\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-125\" src=\"https:\/\/www.gas-sensing.com\/wp\/wp-content\/uploads\/sites\/2\/2017\/02\/Ozone-Sensor-bottom-300x120.png\" alt=\"Aeroqual Ozone Sensor (GSS\/HMOS)\" width=\"300\" height=\"120\" srcset=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Ozone-Sensor-bottom-300x120.png 300w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Ozone-Sensor-bottom-768x307.png 768w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Ozone-Sensor-bottom-624x249.png 624w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2017\/02\/Ozone-Sensor-bottom.png 854w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-125\" class=\"wp-caption-text\">Aeroqual Ozone Sensor (GSS\/HMOS)<\/figcaption><\/figure>\n<p>In heated metal oxide sensors a metal substrate is heated which allows it to become very sensitive to ozone gas. An electrical current passes through the metal substrate. The resistance of the current changes according to the mount of gas present. The sensor outputs the resistance in ppm or ppb.<\/p>\n<p>There are several kinds of HMOS sensors on the market. Different metals and temperature management can have a significant impact on the overall performance of the sensor. Aeroqual\u2019s proprietary technology is branded GSS (gas sensitive semiconductor) to distinguish it from other HMOS available.<\/p>\n<p>The following strengths and weaknesses apply to a state of the art HMOS senso<a href=\"http:\/\/www.aeroqual.com\/ozone\/ozone-products\">r<\/a>.<\/p>\n<h3><span style=\"color: #3366ff\">Advantages<\/span><\/h3>\n<ul>\n<li>Very responsive to low levels of ozone ozone (below 0.1 ppm)<\/li>\n<li>Excellent repeat-ability and accuracy<\/li>\n<li>Long sensor life if stored properly<\/li>\n<li>Very low cross interference from NO2<\/li>\n<\/ul>\n<h3><span style=\"color: #3366ff\">Disadvantages<\/span><\/h3>\n<ul>\n<li>Requires time to warm up (10 minutes after first use)<\/li>\n<li>Slower response time (60 seconds)<\/li>\n<li>Higher power consumption<\/li>\n<li>Cross sensitive to VOCs<\/li>\n<li>Reduced linearity above 1 ppm<\/li>\n<\/ul>\n<h3><span style=\"color: #3366ff\">Applications<\/span><\/h3>\n<ul>\n<li>Ambient (outdoor) ozone monitoring<\/li>\n<li>Health and safety monitoring (especially below 0.1 ppm)<\/li>\n<li>Portable ozone monitoring (especially below 0.1 ppm)<\/li>\n<li>Ozone control scenarios (especially below 0.1 ppm)<\/li>\n<\/ul>\n<h2><span style=\"color: #3366ff\">WHICH IS THE BEST OZONE SENSOR?<\/span><\/h2>\n<p>That really depends on the application.<\/p>\n<p>Electrochemical sensors are less affected by VOC cross-interference than HMOS sensors, but they are extremely (almost 100%) sensitive to NO2 and Cl2. Therefore electrochemical sensors are best suited to indoor and industrial applications while less suited to ambient outdoor applications.<\/p>\n<p>Reliability above 0.1 ppm\u00a0makes electrochemical sensors a good choice for health and safety monitoring. The speed of response and wide range makes them a sensible option for leak detection.<\/p>\n<p>HMOS like <a href=\"https:\/\/www.gas-sensing.com\/replacement-sensors.html?gas=302&amp;manufacturer=28\">Aeroqual\u2019s GSS O3 sensor<\/a> show excellent accuracy and stability below 0.1 ppm. Health and safety regulations around the world are moving towards lower and lower O3 thresholds. If the threshold is below 0.1 ppm then HMOS is really the only option.<\/p>\n<p>In ambient outdoor air monitoring ozone levels are often below 0.1 ppm (100 ppb) so again HMOS are the better choice \u2013 especially when you consider the cross sensitivity of electrochemical\u00a0sensors to NO2 which is nearly always present in ambient air monitoring.<\/p>\n<p>You can read the full article on Aeroqual&#8217;s website: <a href=\"http:\/\/www.aeroqual.com\/electrochemical-sensors-hmos\">http:\/\/www.aeroqual.com\/electrochemical-sensors-hmos<\/a><\/p>\n<p><a href=\"https:\/\/www.gas-sensing.com\/ozone-products.html\">Ozone Gas Monitors<\/a> can be found on our <a href=\"https:\/\/www.gas-sensing.com\/\">Gas Sensings website<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>An interesting article from Aeroqual on the differences between Electrochemical (EC) and Heated Metal Oxide Sensors (HMOS) for measuring ozone. ELECTROCHEMICAL (EC) OZONE SENSORS In [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":125,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[2,35],"tags":[8,22,34],"class_list":["post-121","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gas-sensing","category-ozone","tag-gas-detection-device","tag-gas-monitoring","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/121","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=121"}],"version-history":[{"count":5,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/121\/revisions"}],"predecessor-version":[{"id":722,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/121\/revisions\/722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/125"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=121"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=121"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}