{"id":1322,"date":"2024-02-02T09:00:00","date_gmt":"2024-02-02T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=1322"},"modified":"2024-01-02T09:44:04","modified_gmt":"2024-01-02T15:44:04","slug":"revolutionizing-ozone-detection-os-4-ozone-switch","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/revolutionizing-ozone-detection-os-4-ozone-switch\/","title":{"rendered":"Revolutionizing Ozone Detection: OS-4 Ozone Switch"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the realm of ozone monitoring, precision and reliability are paramount. The OS-4 Ozone Switch, equipped with the cutting-edge SM-EC sensing module, stands out as a remote mount ozone sensor, offering a remarkable detection range of up to 100 meters from the base unit. This blog will provide an in-depth exploration of the OS-4, uncovering its features, applications, specifications, and the seamless integration of replacement sensor technology.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Easy Installation and Minimal Adjustments:<\/em><br>The OS-4 prides itself on its user-friendly design, ensuring ease of installation with minimal adjustments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Replaceable Pre-Calibrated Module:<\/em><br>The sensor, housed in a replaceable pre-calibrated module, is separated from the high ozone area by a cable, enhancing safety.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Temperature and Humidity Compensation:<\/em><br>Sensor readings are temperature and relative humidity compensated, contributing to accurate and reliable measurements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Versatile Power Options:<\/em><br>Operating on 12-24 VDC or AC adapters available worldwide, the OS-4 adapts to different power requirements effortlessly.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Programmable Set-Points:<\/em><br>Tailor the OS-4 to your specific needs with programmable turn-on and turn-off set-points, providing flexibility in ozone concentration control.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Comprehensive Indicators:<\/em><br>With clear LED indicators, the OS-4 keeps you informed\u2014green for instrument activation, yellow for ozone concentration exceeding 0.1 ppm, and red for generator activation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Typical Applications:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Agricultural Storage Monitoring:<\/em> Monitor ozone levels in treatment storage areas for fruits, vegetables, and other agricultural products.<\/li>\n\n\n\n<li><em>HVAC System Monitoring:<\/em> Keep tabs on ozonated HVAC systems for effective control.<\/li>\n\n\n\n<li><em>Industrial Ozone Control:<\/em> Control the output of ozone generators with the set-point controlled relay in the OS-4.<\/li>\n\n\n\n<li><em>Safety Alarms:<\/em> Act as an ozone leak or failure alarm for ozone generators of various sizes.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Specifications:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Range:<\/em> 0.03-20 ppm Electrochemical sensor.<\/li>\n\n\n\n<li><em>Accuracy:<\/em> 10-15% (Depends on application).<\/li>\n\n\n\n<li><em>Temperature and Humidity:<\/em> 5-40\u00b0C, 20-95% RH<\/li>\n\n\n\n<li><em>Measurement Principle:<\/em> HMOS (heated metal oxide semiconductor) sensor.<\/li>\n\n\n\n<li><em>Size:<\/em> 127 \u00d7 64 \u00d7 42 mm (5 \u00d7 2.5 \u00d7 1.625 in).<\/li>\n\n\n\n<li><em>Weight:<\/em> 200 gr (7 oz)<\/li>\n\n\n\n<li><em>Power Requirements:<\/em> 12-24 VDC, 300 mA. AC adapters available.<\/li>\n\n\n\n<li><em>Output Control:<\/em> SPDT non-latching relay, 5 amps, 250 VAC.<\/li>\n\n\n\n<li><em>.1 ppm Danger Alarm:<\/em> Panel LED and SPDT relay 5 amp contacts.<\/li>\n\n\n\n<li><em>Connections:<\/em> Terminal blocks for relay output and DC input. 2.5 mm DC power jack for AC adapter.<\/li>\n\n\n\n<li><em>Indicators:<\/em> Green LED (instrument on), Yellow LED (&gt;0.1 ppm), Red LED (generator on).<\/li>\n\n\n\n<li><em>Outputs:<\/em> 0-2 V, 4-20mA, RS-232 digital.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Range Selection:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The OS-4 is available in a 0-20 ppm range with the SM-EC Electrochemical Sensor. The pre-calibrated sensor chip ensures accuracy, with calibration data stored onboard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Replacement Sensor Technology:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding replacement parts is crucial. The OS-4 comprises the OS-4 base unit, SM-7 sensor module, and the replaceable SM-EC sensor chip. The integration of the SM-EC sensor chip, designed for high humidity and VOC-rich environments, ensures reliable and efficient performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Remote Sensor Installation:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Shipped with a standard cable length, the OS-4 provides flexibility for remote sensor placement. Additional testing suggests using shielded cables for distances beyond 100 feet, with excellent results noted up to 1,000 feet using high-quality cables.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wireless Monitoring &amp; Data Logging Kit:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Enhance your monitoring capabilities with the Wireless Monitoring &amp; Data Logging Kit, facilitating internet connectivity and providing instant notifications via text and email alerts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In conclusion, the OS-4 Ozone Switch emerges as a game-changer in ozone detection technology, offering precision, versatility, and seamless integration for diverse applications. Explore the future of ozone monitoring with the OS-4, setting new standards in safety and efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this ozone monitor here: <a href=\"https:\/\/www.gas-sensing.com\/os4-ozone-monitor.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/os4-ozone-monitor.html\">https:\/\/www.gas-sensing.com\/os4-ozone-monitor.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the realm of ozone monitoring, precision and reliability are paramount. The OS-4 Ozone Switch, equipped with the cutting-edge SM-EC sensing module, stands out as [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":1323,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-1322","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1322","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=1322"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1322\/revisions"}],"predecessor-version":[{"id":1324,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1322\/revisions\/1324"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/1323"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=1322"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=1322"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=1322"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}