{"id":1412,"date":"2024-03-07T08:00:00","date_gmt":"2024-03-07T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=1412"},"modified":"2024-02-27T15:59:38","modified_gmt":"2024-02-27T21:59:38","slug":"a23-14-ozone-calibration-kit-the-answer-to-your-sensor-calibration-needs","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/a23-14-ozone-calibration-kit-the-answer-to-your-sensor-calibration-needs\/","title":{"rendered":"A23-14 Ozone Calibration Kit: The Answer to Your Sensor Calibration Needs"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Are you looking for a reliable and convenient way to calibrate your ATI Ozone Sensors? Look no further than the <a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">A23-14 Ozone Calibration Kit<\/a>. Designed to provide accurate and consistent ozone gas for sensor calibration, this portable kit is a must-have for water treatment professionals, environmental engineers, and anyone working with ozone detection technology.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why Calibration Matters<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Calibration is essential for ensuring the accuracy and reliability of ozone sensors. As ozone gas cannot be stored or provided in standard calibration gas cylinders, it must be produced on-site in known quantities to calibrate your sensors effectively. The <a href=\"https:\/\/www.oxidationtech.com\/a23-14-calibrator.html\">A23-14 Calibra<\/a><a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">tion Kit<\/a> simplifies this process by delivering a consistent flow of calibrated ozone gas for accurate sensor calibration, ensuring optimal performance and peace of mind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features of the A23-14 Calibration Kit<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Portable and Convenient:<\/strong> Housed in a handy portable carry case, the <a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">A23-14 Calibration Kit<\/a> is easy to transport and use on-site, providing flexibility and convenience for calibration tasks.<\/li>\n\n\n\n<li><strong>Versatile Compatibility:<\/strong> While designed for ATI Ozone Sensors, the A23-14 can also be used with other brands and types of ozone sensors, offering versatility and compatibility across various systems.<\/li>\n\n\n\n<li><strong>Simple Operation:<\/strong> Operating the <a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">A23-14 Calibration Kit<\/a> is straightforward. Simply plug the UV generator cell into a power outlet, open the valve on the air cylinder, and connect the outlet tubing to your ozone sensor for calibration. The fixed flow regulator ensures hassle-free operation with no flow control required.<\/li>\n\n\n\n<li><strong>Accurate and Reliable:<\/strong> Each A23-14 generator is individually marked with an accurate ozone gas concentration value, measured prior to shipment, ensuring precision and reliability in sensor calibration.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Specifications and Technical Details<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Generator Type:<\/strong> Ultraviolet<\/li>\n\n\n\n<li><strong>Output:<\/strong> Nominally 0.8 PPM, individually certified<\/li>\n\n\n\n<li><strong>Accuracy:<\/strong> \u00b10.1 PPM<\/li>\n\n\n\n<li><strong>Warm-up Time:<\/strong> 1 minute<\/li>\n\n\n\n<li><strong>Air Supply:<\/strong> 103-liter cylinder with fixed flow regulator<\/li>\n\n\n\n<li><strong>Outlet Flow:<\/strong> 500 cc per minute<\/li>\n\n\n\n<li><strong>Power:<\/strong> 120 VAC, 50\/60 Hz standard (220 VAC optional)<\/li>\n\n\n\n<li><strong>Temperature Limits:<\/strong> 5-40\u00b0 C<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Get Started Today<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Don&#8217;t compromise on the accuracy of your ozone sensor readings. Invest in the<a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\"> A23-14 Ozone Calibration Kit<\/a> and ensure precise and reliable sensor calibration for your water treatment systems, environmental monitoring projects, and more. With its portable design, versatile compatibility, and easy operation, the A23-14 Calibration Kit is the perfect solution for professionals seeking superior performance and peace of mind in ozone detection and measurement. Order yours today and experience the difference!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2024\/02\/a23-14_o3_calibrator_in_case.png\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/blog\/wp-content\/uploads\/2024\/02\/a23-14_o3_calibrator_in_case.png\" alt=\"\" class=\"wp-image-4396\"\/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Are you looking for a reliable and convenient way to calibrate your ATI Ozone Sensors? Look no further than the A23-14 Ozone Calibration Kit. Designed [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":1413,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[35],"tags":[177,176,22,34],"class_list":["post-1412","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone","tag-calibration-kit","tag-calibratoin-kit","tag-gas-monitoring","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=1412"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1412\/revisions"}],"predecessor-version":[{"id":1414,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1412\/revisions\/1414"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/1413"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=1412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=1412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=1412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}