{"id":1840,"date":"2024-09-27T09:00:00","date_gmt":"2024-09-27T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=1840"},"modified":"2024-09-24T10:58:01","modified_gmt":"2024-09-24T15:58:01","slug":"introducing-the-model-480m-ozone-monitor-advanced-accuracy-and-durability-in-ozone-detection","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/introducing-the-model-480m-ozone-monitor-advanced-accuracy-and-durability-in-ozone-detection\/","title":{"rendered":"Introducing the Model 480M Ozone Monitor: Advanced Accuracy and Durability in Ozone Detection"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Model 480M Ozone Monitor<\/strong> is a breakthrough in reliable, long-term ozone monitoring. Built with the user in mind, its modular design ensures easy maintenance while its innovative technology delivers precise, stable readings over extended periods. Housed in a splash-proof <strong>NEMA 4X<\/strong> enclosure, the Model 480M is perfect for demanding environments that require accuracy and durability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Next-Generation Detection Technology<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">At the heart of the Model 480M is its <strong>UV absorption method<\/strong>, which leverages a mercury-free <strong>UV LED source<\/strong> in the detection cell. This cutting-edge technology eliminates the need for traditional UV band-pass filters that deteriorate over time due to UV exposure or humidity. The system uses two detectors: one to measure ozone levels and another to compensate for changes in UV source intensity, ensuring consistent accuracy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This innovative design makes the Model 480M the first of its kind in ozone monitoring, offering an environmentally friendly and stable solution to ozone detection without the use of mercury.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Superior Functionality and Ease of Use<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Equipped with an intuitive graphical user interface, the Model 480M is designed for seamless operation. The <strong>self-adjusting pump<\/strong> extends the device\u2019s operational life, while <strong>built-in diagnostics<\/strong> provide real-time warnings if parameters fall out of range. Users can easily view test values while the unit is operating, and any function that can be set or monitored on the front panel can also be accessed remotely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>modular design<\/strong> of the Model 480M allows for rapid field serviceability, reducing downtime and improving efficiency. Coupled with programmable concentration alarms and <strong>pressure and temperature compensation<\/strong>, this ozone monitor ensures high precision in various operating conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Features<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UV Absorption Method<\/strong>: Reliable and accurate ozone measurement using the Beer-Lambert Law.<\/li>\n\n\n\n<li><strong>Mercury-Free UV LED Source<\/strong>: Environmentally friendly and long-lasting, eliminating the need for mercury.<\/li>\n\n\n\n<li><strong>Ranges from 0-1,000 ppm to 0-10,000 ppm<\/strong>: Suitable for a variety of applications.<\/li>\n\n\n\n<li><strong>Built-In Diagnostics<\/strong>: Continuous monitoring of operating parameters to ensure optimal performance.<\/li>\n\n\n\n<li><strong>Modular Internal Design<\/strong>: Easier maintenance and increased uptime.<\/li>\n\n\n\n<li><strong>Minimal Zero Drift<\/strong>: Ensures long-term accuracy and stability.<\/li>\n\n\n\n<li><strong>Temperature and Pressure Compensation<\/strong>: Provides consistent accuracy in varying environmental conditions.<\/li>\n\n\n\n<li><strong>Ethernet Connectivity<\/strong>: For improved remote communication (WiFi option coming soon).<\/li>\n\n\n\n<li><strong>Programmable Alarms<\/strong>: Set concentration-based alerts for safe operation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Enhanced Communication for Greater Productivity<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With <strong>standard Ethernet<\/strong> connectivity, the Model 480M allows for streamlined data communication and remote access. The upcoming <strong>WiFi functionality<\/strong> will further enhance user interaction with the system. Remote monitoring ensures you can keep track of performance, make adjustments, and receive alerts from anywhere.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specifications at a Glance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Range<\/strong>: 0-1,000 ppm to 0-10,000 ppm.<\/li>\n\n\n\n<li><strong>Precision\/Repeatability<\/strong>: \u00b1 0.5% of full scale.<\/li>\n\n\n\n<li><strong>Response Time<\/strong>: Less than 45 seconds to 95%.<\/li>\n\n\n\n<li><strong>Temperature Range<\/strong>: 5\u00b0C to 45\u00b0C.<\/li>\n\n\n\n<li><strong>Power Requirements<\/strong>: 110-240VAC, 50\/60Hz, 74W.<\/li>\n\n\n\n<li><strong>Enclosure<\/strong>: Splash-proof NEMA 4X (IP65 rating).<\/li>\n\n\n\n<li><strong>Weight<\/strong>: 17.6 lbs (8 kg).<\/li>\n\n\n\n<li><strong>Analog Outputs<\/strong>: 0-5V or 4-20mA isolated output.<\/li>\n\n\n\n<li><strong>Gas Flow Rate<\/strong>: 0.8 LPM.<\/li>\n\n\n\n<li><strong>Gas Inlet Pressure Range<\/strong>: 11.0 &#8211; 16.0 psia.<\/li>\n\n\n\n<li><strong>Approvals<\/strong>: CE Certified.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Built for Demanding Applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480M is engineered to withstand harsh environments while maintaining superior performance. The NEMA 4X enclosure ensures protection against dust, water, and other environmental factors, making it ideal for a range of industrial applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conclusion<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Model 480M Ozone Monitor<\/strong> sets a new standard in ozone detection with its advanced technology, user-friendly design, and high durability. From its mercury-free UV LED source to its modular design and robust communication features, the Model 480M is the perfect solution for accurate, reliable ozone monitoring in both industrial and environmental applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/480m.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/480m.html\">https:\/\/www.gas-sensing.com\/480m.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Model 480M Ozone Monitor is a breakthrough in reliable, long-term ozone monitoring. Built with the user in mind, its modular design ensures easy maintenance [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":1841,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-1840","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=1840"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1840\/revisions"}],"predecessor-version":[{"id":1842,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1840\/revisions\/1842"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/1841"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=1840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=1840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=1840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}