{"id":1986,"date":"2024-12-02T09:00:00","date_gmt":"2024-12-02T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=1986"},"modified":"2024-11-25T09:24:10","modified_gmt":"2024-11-25T15:24:10","slug":"model-480l-advanced-ozone-monitoring-with-modular-design","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/model-480l-advanced-ozone-monitoring-with-modular-design\/","title":{"rendered":"Model 480L: Advanced Ozone Monitoring with Modular Design"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>Model 480L<\/strong> ozone monitor redefines performance and reliability in industrial and safety monitoring. With its <strong>mercury-free UV LED detection cell<\/strong> and a modular design, the 480L ensures precision and simplicity in even the most demanding environments. Available in single-stream and multi-channel configurations (up to six streams), the 480L provides unmatched flexibility for monitoring ozone concentrations across multiple sample points.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Key Features of the Model 480L<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UV Absorption Method:<\/strong> Accurate measurement based on the Beer-Lambert Law, ensuring precision and reliability.<\/li>\n\n\n\n<li><strong>Mercury-Free UV LED Source:<\/strong> Safer and more sustainable than traditional mercury lamps, with improved longevity.<\/li>\n\n\n\n<li><strong>Modular Design:<\/strong> Simplifies maintenance and enhances field serviceability.<\/li>\n\n\n\n<li><strong>Diagnostics and Alerts:<\/strong> Built-in warnings, error logs, and self-diagnostics keep you informed of any operating issues.<\/li>\n\n\n\n<li><strong>Flexible Communication:<\/strong> Ethernet standard with WiFi (coming soon), plus RS-232 and RS-485 interfaces.<\/li>\n\n\n\n<li><strong>Customizable Alarms:<\/strong> Programmable concentration alarms for safety monitoring.<\/li>\n\n\n\n<li><strong>Multi-Stream Capability:<\/strong> Available in one, three, or six-stream configurations, cycling between streams in as little as one minute.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Specifications<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480L is designed for high accuracy and precision, with a detection range of <strong>0-1 ppm to 0-500 ppm<\/strong> and a lower detectable limit of <strong>0.003 ppm<\/strong>. Additional highlights include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Precision:<\/strong> \u00b1 0.5% of full scale<\/li>\n\n\n\n<li><strong>Accuracy:<\/strong> \u00b1 1% of full scale<\/li>\n\n\n\n<li><strong>Response Time:<\/strong> Less than 30 seconds to 95% of the reading<\/li>\n\n\n\n<li><strong>Minimal Zero Drift:<\/strong> 0.005 ppm\/month<\/li>\n\n\n\n<li><strong>Temperature Range:<\/strong> Operates in environments from 5\u00b0C to 45\u00b0C<\/li>\n\n\n\n<li><strong>Power Requirements:<\/strong> 100-240VAC, 50\/60Hz, 74W<\/li>\n\n\n\n<li><strong>Sample Flow Rate:<\/strong> 0.8 LPM<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Why Choose the Model 480L?<\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Ease of Use<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>intuitive graphical user interface<\/strong> and menu-driven setup make it operator-friendly, while real-time parameter displays ensure ease of monitoring and adjustments.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Maximized Uptime<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">With self-adjusting pumps, built-in diagnostics, and modular design, the Model 480L minimizes downtime and simplifies maintenance.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Safety First<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480L ensures safety compliance with its <strong>programmable alarms<\/strong> and ability to measure ozone at low detection limits, maintaining a secure work environment.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Applications of the Model 480L<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480L\u2019s versatility makes it ideal for various industries, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Environmental Monitoring:<\/strong> Multi-stream configuration allows monitoring of several points in industrial facilities.<\/li>\n\n\n\n<li><strong>Industrial Safety:<\/strong> Reliable alarms protect workers from exposure to hazardous ozone levels.<\/li>\n\n\n\n<li><strong>Research and Development:<\/strong> Precision and repeatability support detailed studies and controlled experiments.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Model 480L Ozone Monitor<\/strong> is an innovative and reliable solution for precise ozone detection. Its robust features, such as mercury-free detection, modular design, and flexible communication options, make it an essential tool for industries that prioritize safety and efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/480l.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/480l.html\">https:\/\/www.gas-sensing.com\/480l.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Model 480L ozone monitor redefines performance and reliability in industrial and safety monitoring. With its mercury-free UV LED detection cell and a modular design, [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":1987,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-1986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=1986"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1986\/revisions"}],"predecessor-version":[{"id":1988,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1986\/revisions\/1988"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/1987"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=1986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=1986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=1986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}