{"id":1992,"date":"2024-12-03T09:00:00","date_gmt":"2024-12-03T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=1992"},"modified":"2024-11-26T08:27:37","modified_gmt":"2024-11-26T14:27:37","slug":"precision-ozone-measurement-with-the-uv-106l-oem-ozone-analyzer","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/precision-ozone-measurement-with-the-uv-106l-oem-ozone-analyzer\/","title":{"rendered":"Precision Ozone Measurement with the UV-106L OEM Ozone Analyzer"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">For industries and research applications requiring precise ozone measurement in a compact design, the <strong>UV-106L OEM Ozone Analyzer<\/strong> delivers unparalleled performance. With its innovative &#8220;Ozone Analyzer on a board&#8221; configuration, this instrument combines advanced functionality with flexibility, making it an ideal solution for low-range ozone monitoring. Here\u2019s everything you need to know about this remarkable device.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Features of the UV-106L OEM Ozone Analyzer<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Low-Range Precision with OEM Configuration<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106L stands out with its ability to measure ozone concentrations with incredible accuracy, offering a resolution of <strong>0.0001 ppm (0.1 ppb)<\/strong> and a detection range up to <strong>100 ppm<\/strong>. This precision is achieved using <strong>UV absorption technology<\/strong>, a trusted method for detecting ozone that minimizes cross-sensitivity from other gases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The OEM design integrates nearly all components directly onto the printed circuit board, optimizing space and simplifying integration into custom systems.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Compact, Efficient, and Easy to Use<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Designed for flexibility and ease of operation, the analyzer features:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Low power consumption<\/strong>, enabling battery operation for portable or remote applications.<\/li>\n\n\n\n<li>An <strong>internal sample pump<\/strong> to draw gas from the source into the analyzer.<\/li>\n\n\n\n<li>An onboard microprocessor with <strong>interactive menus<\/strong> for data management, including customizable averaging intervals (10 seconds to 1 hour).<\/li>\n\n\n\n<li>Multiple output options, including <strong>USB, RS-232, analog (0-2.5 V, 4-20 mA)<\/strong>, and <strong>relay controls<\/strong> for automation.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Data Logging and Real-Time Monitoring<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The integrated <strong>data logger with a real-time clock<\/strong> provides seamless tracking of ozone levels, internal temperature, and pressure. This feature ensures reliable data collection for ongoing monitoring or detailed analysis.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Built for Durability and Versatility<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Whether used in a laboratory or industrial setting, the UV-106L offers flexibility:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Standard Bench-Mount Enclosure<\/strong>: Perfect for general applications and quick setups.<\/li>\n\n\n\n<li><strong>Rugged NEMA Enclosure<\/strong>: Designed for wall-mount installations or use in harsh environments.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How It Works: UV Absorption Technology<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106L determines ozone concentrations by measuring the rate of UV light absorption in the gas sample. A UV lamp and receptor work in tandem, ensuring accurate detection even at ultra-low levels. This approach virtually eliminates interference from other gases, making it a reliable choice for sensitive environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Maintenance and Accessories<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Filter and Ozone Scrubber Replacement<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To maintain accuracy and prevent contamination:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Replace the <strong>filter<\/strong> regularly to keep particulate matter from affecting the flow path.<\/li>\n\n\n\n<li>Swap out the <strong>internal ozone scrubber<\/strong> as needed to sustain optimal performance.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These simple maintenance steps ensure the analyzer continues to deliver consistent, precise measurements.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Applications and Use Cases<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106L is ideal for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial process monitoring.<\/li>\n\n\n\n<li>Laboratory research.<\/li>\n\n\n\n<li>Air quality testing.<\/li>\n\n\n\n<li>Temporary monitoring setups (rentals available for short-term projects).<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Choose the UV-106L OEM Ozone Analyzer?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">With its compact design, high-resolution capability, and robust features, the UV-106L offers unmatched precision in ozone measurement. Whether integrated into custom systems or used as a standalone device, this analyzer provides the reliability and performance you need for critical applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/uv-106l-oem-ozone-analyzer.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/uv-106l-oem-ozone-analyzer.html\">https:\/\/www.gas-sensing.com\/uv-106l-oem-ozone-analyzer.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>For industries and research applications requiring precise ozone measurement in a compact design, the UV-106L OEM Ozone Analyzer delivers unparalleled performance. With its innovative &#8220;Ozone [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":1993,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-1992","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=1992"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1992\/revisions"}],"predecessor-version":[{"id":1994,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/1992\/revisions\/1994"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/1993"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=1992"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=1992"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=1992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}