{"id":2025,"date":"2024-12-17T09:00:00","date_gmt":"2024-12-17T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2025"},"modified":"2024-12-16T09:03:58","modified_gmt":"2024-12-16T15:03:58","slug":"meet-the-uv-106-h-the-high-range-ozone-analyzer-for-precision-measurement","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/meet-the-uv-106-h-the-high-range-ozone-analyzer-for-precision-measurement\/","title":{"rendered":"Meet the UV-106-H: The High-Range Ozone Analyzer for Precision Measurement"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">For professionals working with ozone in industrial processes, precision and reliability in measurement are essential. The <strong>UV-106-H High-Range Ozone Analyzer<\/strong> is designed to meet this need, offering <strong>accurate ozone measurements up to 20% by weight (14% by volume)<\/strong>. Whether you\u2019re monitoring ozone production or verifying generator output, the UV-106-H delivers exceptional performance in a compact, versatile design.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Accurate Ozone Measurement at High Levels<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-H uses <strong>UV absorption technology<\/strong> to detect ozone concentration with impressive resolution and accuracy. This method calculates ozone levels by measuring the rate at which ozone absorbs ultraviolet light.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Key specifications include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Range:<\/strong> 0-20% by weight, or 0-14% by volume<\/li>\n\n\n\n<li><strong>Resolution:<\/strong> 0.01%<\/li>\n\n\n\n<li><strong>Internal Sample Pump:<\/strong> Draws gas directly from your process for real-time analysis<\/li>\n\n\n\n<li><strong>Integrated Data Logging:<\/strong> Track and analyze results with time\/date stamps<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>OEM Configuration: Ozone Analysis on a Board<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-H is available in an <strong>OEM configuration<\/strong>, where nearly all components are mounted directly to the printed circuit board. This makes it ideal for integration into custom systems or compact setups.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For standalone use, the analyzer is available in two main configurations:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Bench Mount Enclosure<\/strong><br>A compact, easy-to-use design perfect for tabletop applications.<\/li>\n\n\n\n<li><strong>NEMA Industrial Enclosure<\/strong><br>Rugged and wall-mountable, this option is tailored for harsher environments or industrial setups requiring added durability.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Built for Versatility and Convenience<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you need temporary monitoring or a permanent solution, the UV-106-H offers options to fit a variety of needs. It features low power consumption and can even run on battery power. Outputs include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Digital:<\/strong> USB and RS-232, providing time, date, ozone concentration, temperature, and pressure.<\/li>\n\n\n\n<li><strong>Analog:<\/strong> 0-2.5 V and 4-20 mA for user-selected units.<\/li>\n\n\n\n<li><strong>Control Functions:<\/strong> Two-level relays for controlling external devices, such as ozone sources or warning systems.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Rental Options and Maintenance Tips<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For those needing short-term monitoring, the UV-106-H is available for <strong>rental<\/strong>. This provides a cost-effective way to manage temporary projects or one-off applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To ensure consistent accuracy and performance, regular maintenance is recommended:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Replace Filters Regularly<\/strong><br>Frequent filter replacement prevents contamination of the flow path by particulate matter.<\/li>\n\n\n\n<li><strong>Maintain the Ozone Scrubber<\/strong><br>The built-in scrubber removes ozone before venting, and routine replacement is necessary to maintain system integrity.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Applications of the UV-106-H Ozone Analyzer<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">From process control to generator verification, the UV-106-H is a versatile tool in industries such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ozone generator manufacturing<\/strong><\/li>\n\n\n\n<li><strong>Water treatment facilities<\/strong><\/li>\n\n\n\n<li><strong>Industrial processes requiring ozone monitoring<\/strong><\/li>\n\n\n\n<li><strong>Environmental testing<\/strong><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Why Choose the UV-106-H?<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-H is more than just an ozone analyzer\u2014it\u2019s a solution designed for precision, reliability, and ease of use. Whether you\u2019re monitoring high ozone concentrations or integrating the device into an existing system, it offers unmatched functionality in both standard and rugged environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/uv106h-ozone-analyzer.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/uv106h-ozone-analyzer.html\">https:\/\/www.gas-sensing.com\/uv106h-ozone-analyzer.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>For professionals working with ozone in industrial processes, precision and reliability in measurement are essential. The UV-106-H High-Range Ozone Analyzer is designed to meet this [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2025","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2025"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2025\/revisions"}],"predecessor-version":[{"id":2026,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2025\/revisions\/2026"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}