{"id":2068,"date":"2025-01-10T09:00:00","date_gmt":"2025-01-10T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2068"},"modified":"2025-01-07T11:10:54","modified_gmt":"2025-01-07T17:10:54","slug":"introducing-the-model-480m-advanced-ozone-monitoring-with-unmatched-accuracy","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/introducing-the-model-480m-advanced-ozone-monitoring-with-unmatched-accuracy\/","title":{"rendered":"Introducing the Model 480M: Advanced Ozone Monitoring with Unmatched Accuracy"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>Model 480M Ozone Monitor<\/strong> is a cutting-edge solution for precise and reliable ozone monitoring in industrial and environmental applications. Designed with the user in mind, this innovative monitor combines exceptional accuracy, modular design for easy maintenance, and a host of features to ensure optimal performance and uptime.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Key Features of the Model 480M<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Accurate UV Absorption Technology<\/strong>:\n<ul class=\"wp-block-list\">\n<li>The Model 480M utilizes the <strong>UV absorption method (Beer-Lambert Law)<\/strong>, ensuring highly accurate readings with minimal zero drift.<\/li>\n\n\n\n<li>Two detectors are employed: one for ozone measurement and another to compensate for UV source intensity changes, eliminating the need for UV band-pass filters that degrade over time.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Mercury-Free UV LED Source<\/strong>:\n<ul class=\"wp-block-list\">\n<li>This environmentally friendly feature makes the Model 480M the first of its kind, offering greater durability and reliability.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Modular Design for Easy Maintenance<\/strong>:\n<ul class=\"wp-block-list\">\n<li>The modular internal components allow for easy field serviceability, reducing downtime and simplifying repairs.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>User-Friendly Interface<\/strong>:\n<ul class=\"wp-block-list\">\n<li>The intuitive graphical user interface makes the Model 480M easy to operate, with test values and diagnostics accessible in real time.<\/li>\n\n\n\n<li>All functions can be remotely set or monitored for maximum convenience.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Enhanced Communication and Diagnostics<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Built-in diagnostics provide alerts for operating parameters out of range, ensuring immediate action when needed.<\/li>\n\n\n\n<li>Advanced communication options, including Ethernet (WiFi coming soon), allow seamless integration into existing systems.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Wide Measurement Range<\/strong>:\n<ul class=\"wp-block-list\">\n<li>With ranges from <strong>0-1,000 ppm to 0-10,000 ppm<\/strong>, the Model 480M is suitable for various applications, offering unmatched flexibility.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Specifications Overview<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Feature<\/strong><\/th><th><strong>Details<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Measurement Range<\/strong><\/td><td>0-1,000 ppm to 0-10,000 ppm<\/td><\/tr><tr><td><strong>Precision\/Repeatability<\/strong><\/td><td>\u00b1 0.5% of full scale<\/td><\/tr><tr><td><strong>Response Time<\/strong><\/td><td>&lt; 45 seconds to 95%<\/td><\/tr><tr><td><strong>Lower Detectable Limit<\/strong><\/td><td>0.003 ppm<\/td><\/tr><tr><td><strong>Compensation<\/strong><\/td><td>Pressure, Temperature<\/td><\/tr><tr><td><strong>Power<\/strong><\/td><td>110-240VAC, 50\/60Hz, 74W<\/td><\/tr><tr><td><strong>Enclosure<\/strong><\/td><td>Splash-proof NEMA 4X (IP65)<\/td><\/tr><tr><td><strong>Dimensions (H x W x D)<\/strong><\/td><td>17.15\u201d x 15.96\u201d x 6.80\u201d<\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>17.6 lbs (8 kg)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Why Choose the Model 480M?<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Long-Term Stability<\/strong>: Designed for accurate, stable readings over extended periods.<\/li>\n\n\n\n<li><strong>Environmentally Friendly<\/strong>: Mercury-free UV LED source ensures sustainable monitoring.<\/li>\n\n\n\n<li><strong>Maximum Uptime<\/strong>: Self-diagnostics, modular design, and robust construction minimize maintenance and downtime.<\/li>\n\n\n\n<li><strong>Versatile Applications<\/strong>: Suitable for industrial processes, environmental monitoring, and more.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Applications<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Model 480M is ideal for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial ozone system monitoring.<\/li>\n\n\n\n<li>Environmental compliance and air quality assessment.<\/li>\n\n\n\n<li>Research and laboratory applications requiring precise ozone measurements.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Built for Reliability and Ease of Use<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">From its splash-proof NEMA 4X enclosure to its advanced features like temperature and pressure compensation, the Model 480M is engineered for reliability in the most demanding environments. The mercury-free UV LED source, along with an intuitive interface, ensures safe, sustainable, and easy operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Contact Us for More Information<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ready to upgrade your ozone monitoring capabilities? The Model 480M offers the precision, durability, and flexibility you need for long-term success. Contact us today to learn more or request a quote!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/480m.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/480m.html\">https:\/\/www.gas-sensing.com\/480m.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Model 480M Ozone Monitor is a cutting-edge solution for precise and reliable ozone monitoring in industrial and environmental applications. Designed with the user in [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2069,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2068","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2068","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2068"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2068\/revisions"}],"predecessor-version":[{"id":2070,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2068\/revisions\/2070"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2069"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2068"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2068"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2068"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}