{"id":2149,"date":"2025-02-17T09:00:00","date_gmt":"2025-02-17T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2149"},"modified":"2025-02-05T09:46:56","modified_gmt":"2025-02-05T15:46:56","slug":"a23-14-ozone-calibration-kit-ensuring-accurate-ozone-sensor-calibration","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/a23-14-ozone-calibration-kit-ensuring-accurate-ozone-sensor-calibration\/","title":{"rendered":"A23-14 Ozone Calibration Kit: Ensuring Accurate Ozone Sensor Calibration"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>Portable, Reliable, and Precise Ozone Calibration<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Proper calibration of ozone sensors is essential for maintaining accuracy in environmental monitoring, safety compliance, and industrial applications. The <strong>A23-14 Ozone Generator Calibration Kit<\/strong> is designed specifically for calibrating <strong>ATI ozone sensors<\/strong>, ensuring consistent and precise ozone gas generation. Unlike other gases, <strong>ozone cannot be stored in calibration gas cylinders<\/strong>\u2014it must be produced on-site in controlled quantities. The <strong>A23-14<\/strong> provides a <strong>reliable, portable solution<\/strong> for field and laboratory calibration.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Choose the A23-14 Calibration Kit?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Portable and Easy to Use<\/strong> \u2013 Housed in a <strong>durable carrying case<\/strong>, the A23-14 allows calibration at any location.<\/li>\n\n\n\n<li><strong>Consistent and Accurate Ozone Generation<\/strong> \u2013 Produces a controlled <strong>ozone concentration below 1 PPM<\/strong>, ensuring precise calibration.<\/li>\n\n\n\n<li><strong>Compatible with Multiple Ozone Sensors<\/strong> \u2013 While designed for <strong>ATI sensors<\/strong>, the A23-14 can be used for other ozone monitoring devices as well.<\/li>\n\n\n\n<li><strong>No Flow Control Required<\/strong> \u2013 The <strong>fixed flow regulator<\/strong> eliminates the need for manual adjustments, simplifying operation.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How the A23-14 Ozone Generator Works<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>A23-14 uses a compressed air cylinder<\/strong> to supply dry air to an <strong>ultraviolet (UV) cell<\/strong>, where ozone gas is generated. The <strong>ozone-enriched air<\/strong> exits the generator through <strong>fluorocarbon tubing<\/strong>, which delivers a precise ozone standard to the <strong>ozone sensor<\/strong> for calibration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Simple 3-Step Operation:<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Plug the UV generator cell<\/strong> into any standard power outlet.<\/li>\n\n\n\n<li><strong>Open the valve on the compressed air cylinder<\/strong> (pre-set for consistent flow).<\/li>\n\n\n\n<li><strong>Connect the outlet tubing to your ozone sensor<\/strong> and calibrate as needed.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Each unit is <strong>pre-calibrated before shipment<\/strong>, with the exact ozone concentration value clearly marked.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>What\u2019s Included in the A23-14 Calibration Kit?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The A23-14 is packaged in a <strong>rugged molded case<\/strong> for portability and includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ozone Generator<\/strong> (UV-based)<\/li>\n\n\n\n<li><strong>103-liter compressed air cylinder<\/strong> with a <strong>fixed flow regulator<\/strong><\/li>\n\n\n\n<li><strong>Three feet of fluorocarbon outlet tubing<\/strong><\/li>\n\n\n\n<li><strong>Calibration adapters<\/strong> for sensor connection<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Compatible Sensors and Applications<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The A23-14 is designed for use with <strong>ATI ozone sensors<\/strong>, such as the <strong>Q45\/65 Dissolved Ozone Monitor<\/strong>, but can also be used with other brands of ozone detection equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Ideal for:<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Environmental monitoring<\/strong><\/li>\n\n\n\n<li><strong>Industrial ozone applications<\/strong><\/li>\n\n\n\n<li><strong>Health and safety compliance<\/strong><\/li>\n\n\n\n<li><strong>Water treatment facilities<\/strong><\/li>\n\n\n\n<li><strong>Laboratory calibration procedures<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Accurate Calibration Matters<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Regular calibration of ozone sensors ensures:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Accurate ozone measurements<\/strong> for reliable data collection<\/li>\n\n\n\n<li><strong>Compliance with safety regulations<\/strong> and environmental standards<\/li>\n\n\n\n<li><strong>Consistent performance<\/strong> of ozone monitoring systems<\/li>\n\n\n\n<li><strong>Reduced downtime and maintenance costs<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Order Your A23-14 Ozone Calibration Kit Today<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For professionals in <strong>air quality monitoring, industrial safety, and environmental compliance<\/strong>, the <strong>A23-14 Ozone Calibration Kit<\/strong> provides a <strong>trusted and efficient calibration solution<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">https:\/\/www.gas-sensing.com\/a23-14-calibrator.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Portable, Reliable, and Precise Ozone Calibration Proper calibration of ozone sensors is essential for maintaining accuracy in environmental monitoring, safety compliance, and industrial applications. The [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2150,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2149","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2149"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2149\/revisions"}],"predecessor-version":[{"id":2151,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2149\/revisions\/2151"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2150"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}