{"id":2327,"date":"2025-05-06T09:00:00","date_gmt":"2025-05-06T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2327"},"modified":"2025-05-05T08:24:10","modified_gmt":"2025-05-05T13:24:10","slug":"high-range-ozone-measurement-simplified-introducing-the-uv-106-mh-with-nema-enclosure","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/high-range-ozone-measurement-simplified-introducing-the-uv-106-mh-with-nema-enclosure\/","title":{"rendered":"High-Range Ozone Measurement Simplified: Introducing the UV-106-MH with NEMA Enclosure"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">When it comes to monitoring ozone output from high-concentration ozone generators, precision and durability are essential. The <strong>UV-106-MH<\/strong> ozone analyzer, now available in a rugged <strong>NEMA enclosure<\/strong>, delivers both\u2014offering <strong>accurate ozone measurement up to 20% by weight (or 14% by volume)<\/strong> while withstanding demanding environmental conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Powerful Measurement Capabilities<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-MH is a <strong>high-range ozone analyzer<\/strong> engineered for industrial and process applications where <strong>ozone generator output verification<\/strong> is required. This model stands out with a wide measurement range:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>0\u201320% ozone by weight<\/strong><\/li>\n\n\n\n<li><strong>0\u201314% ozone by volume<\/strong><\/li>\n\n\n\n<li><strong>0.01% resolution<\/strong>, providing fine detail and accuracy at high concentrations<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">At the heart of the UV-106-MH is a <strong>UV absorption-based detection system<\/strong>. An internal <strong>UV lamp and receptor<\/strong> measure ozone concentration by evaluating how ozone absorbs ultraviolet light. This technique ensures <strong>highly accurate and reliable measurements<\/strong>, even in ozone-rich environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Built for Real-World Conditions: The NEMA Enclosure<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With the <strong>NEMA-rated protective enclosure<\/strong>, the UV-106-MH becomes even more versatile. The rugged case allows for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Shelf placement or secure mounting<\/strong><\/li>\n\n\n\n<li><strong>Enhanced durability<\/strong> in industrial settings<\/li>\n\n\n\n<li><strong>Protection from dust, moisture, and physical damage<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Whether used in the field or in a lab, the NEMA configuration ensures your analyzer remains protected and operational.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Integrated Pump for Process Sampling<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">An <strong>integrated sample pump<\/strong> is built into the UV-106-MH, making it ideal for <strong>pulling ozone samples directly from a process line or environment<\/strong>. This feature simplifies deployment and ensures a representative sample is consistently delivered to the sensor.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>User-Friendly Technology, Advanced Output Options<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Designed with ease of use and data accessibility in mind, the UV-106-MH includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>On-board microprocessor<\/strong> with interactive menus<\/li>\n\n\n\n<li><strong>Data averaging<\/strong> options: 10 seconds, 1 minute, 5 minutes, and 1 hour<\/li>\n\n\n\n<li><strong>Internal data logger<\/strong> with real-time clock<\/li>\n\n\n\n<li><strong>USB and RS-232 outputs<\/strong> for seamless data integration<\/li>\n\n\n\n<li><strong>Analog output (0\u20132.5 V and 4\u201320 mA)<\/strong> for ozone concentration in user-selected units<\/li>\n\n\n\n<li><strong>Two-level relay control<\/strong> to automate processes or trigger alarms<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Despite its powerful features, the unit is <strong>low power<\/strong> and can even be <strong>battery operated<\/strong>\u2014an excellent option for mobile or remote applications.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Multiple Configurations: Standard, NEMA, and OEM<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Standard Bench Mount:<\/strong> Ideal for lab or benchtop use.<\/li>\n\n\n\n<li><strong>NEMA Enclosure:<\/strong> Best for industrial settings or permanent installations.<\/li>\n\n\n\n<li><strong>OEM Version:<\/strong> A compact, enclosure-free design with components mounted directly to the circuit board\u2014perfect for integrators and custom applications.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Maintenance Essentials: Filters and Ozone Scrubber<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To ensure optimal performance and accuracy:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Replace the filter frequently<\/strong> to prevent particulate contamination.<\/li>\n\n\n\n<li><strong>Replace the internal ozone scrubber regularly<\/strong> to maintain clean flow paths and prolong the life of the device.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Final Thoughts<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-MH with NEMA enclosure is a reliable, high-precision solution for <strong>monitoring ozone at industrial-strength concentrations<\/strong>. With a range of configurations and robust features, it offers unmatched versatility and accuracy for process engineers, researchers, and OEM integrators alike.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you\u2019re looking for a durable, high-range ozone analyzer that\u2019s ready for real-world conditions, the UV-106-MH should be at the top of your list.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/uv-106mh-nema.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/uv-106mh-nema.html\">https:\/\/www.gas-sensing.com\/uv-106mh-nema.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>When it comes to monitoring ozone output from high-concentration ozone generators, precision and durability are essential. The UV-106-MH ozone analyzer, now available in a rugged [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2328,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2327","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2327"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2327\/revisions"}],"predecessor-version":[{"id":2329,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2327\/revisions\/2329"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2328"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}