{"id":2362,"date":"2025-05-21T09:00:00","date_gmt":"2025-05-21T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2362"},"modified":"2025-05-20T08:58:49","modified_gmt":"2025-05-20T13:58:49","slug":"b12-wet-gas-transmitter-reliable-gas-detection-in-saturated-environments","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/b12-wet-gas-transmitter-reliable-gas-detection-in-saturated-environments\/","title":{"rendered":"B12 Wet Gas Transmitter: Reliable Gas Detection in Saturated Environments"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Gas detection in high-humidity or wet environments can be a challenge\u2014especially when the air is saturated with water vapor. Traditional gas detectors often fail or deliver unreliable readings when exposed to moisture-laden streams. That\u2019s where the <strong>B12 Wet Gas Transmitter<\/strong> from <strong>Analytical Technology, Inc. (ATI)<\/strong> stands out as a game-changer.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Engineered for 100% Humidity<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Designed specifically for <strong>wet gas streams<\/strong>, the B12 Wet Gas Transmitter is built to perform in environments where other sensors fail. Whether you&#8217;re monitoring the outlet of a wet scrubber or sampling vent stacks saturated with moisture, the B12 provides accurate and consistent gas measurements where it counts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Key highlights:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>100% RH Compatible<\/strong> \u2013 Designed to operate in fully saturated environments<\/li>\n\n\n\n<li><strong>Corrosion-resistant sensor<\/strong> \u2013 For long-term performance and durability<\/li>\n\n\n\n<li><strong>Direct insertion or flowcell options<\/strong> \u2013 Flexible installation based on your setup<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Built-in LCD Display for Easy Monitoring<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The B12 is available in a <strong>NEMA 4X version with a built-in LCD display<\/strong>, allowing users to see real-time gas concentrations right at the detection point. This is a highly valuable feature for operators and technicians, eliminating the guesswork and enhancing on-site safety monitoring.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Note<\/strong>: The LCD display <strong>must be ordered at the time of purchase<\/strong> and cannot be added afterward.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Flexible System Integration<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The B12 can operate as a <strong>standalone sensor<\/strong>, sending a 4-20 mA signal directly to your <strong>DCS, PLC, or SCADA system<\/strong>. For added functionality, it can also be paired with ATI\u2019s <strong>B14 Alarm Receiver System<\/strong>, providing:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Digital concentration display<\/li>\n\n\n\n<li>Three programmable alarm setpoints<\/li>\n\n\n\n<li>Remote alarm reset input<\/li>\n\n\n\n<li>4-20 mA retransmission output<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This flexible approach allows you to build a system tailored to your specific site needs and budget.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Choose Your Sensor Module<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The B12 Wet Gas Transmitter is compatible with a wide range of gas sensors, allowing customization based on your application. Each sensor can be calibrated for custom detection ranges.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Gas<\/th><th>Standard Range<\/th><th>Min Range<\/th><th>Max Range<\/th><\/tr><\/thead><tbody><tr><td>Chlorine (Cl\u2082)<\/td><td>0\u201320 ppm<\/td><td>0\u20131 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Bromine (Br\u2082)<\/td><td>0\u201320 ppm<\/td><td>0\u20131 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Chlorine Dioxide (ClO\u2082)<\/td><td>0\u201320 ppm<\/td><td>0\u20131 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Ozone (O\u2083)<\/td><td>0\u201320 ppm<\/td><td>0\u20131 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Hydrogen Chloride (HCl)<\/td><td>0\u201320 ppm<\/td><td>0\u201310 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Hydrogen Fluoride (HF)<\/td><td>0\u201320 ppm<\/td><td>0\u201310 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Hydrogen Bromide (HBr)<\/td><td>0\u201320 ppm<\/td><td>0\u201310 ppm<\/td><td>0\u2013100 ppm<\/td><\/tr><tr><td>Hydrogen (H\u2082, %)<\/td><td>0\u20134%<\/td><td>0\u20131%<\/td><td>0\u201310%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Need a specific range? Custom calibrations are available for an additional fee.<\/em><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Ordering Options &amp; Enclosures<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When configuring your B12 transmitter, choose from these enclosure and display options:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Standard NEMA 4X<\/strong>: Rugged and suitable for most indoor and outdoor applications<\/li>\n\n\n\n<li><strong>Explosion-proof enclosure<\/strong>: Galvanized steel for hazardous environments (Note: LCD display not available with this option)<\/li>\n\n\n\n<li><strong>NEMA 4X with LCD display<\/strong>: For maximum utility and on-site monitoring, includes separated sensor with 25 feet of cable<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All versions come with <strong>zero and span potentiometers<\/strong> for easy calibration and <strong>sensor cable<\/strong> that can be extended up to 100 feet.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Specifications at a Glance<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>Value<\/th><\/tr><\/thead><tbody><tr><td>Accuracy<\/td><td>\u00b15% of value (limited by calibration gas)<\/td><\/tr><tr><td>Repeatability<\/td><td>\u00b11% of span<\/td><\/tr><tr><td>Linearity<\/td><td>\u00b10.5% of span<\/td><\/tr><tr><td>Output<\/td><td>4-20 mA loop-powered (675 ohms max @ 24 VDC)<\/td><\/tr><tr><td>Power<\/td><td>12\u201328 VDC<\/td><\/tr><tr><td>Operating Temp<\/td><td>0\u00b0C to 50\u00b0C (32\u00b0F to 122\u00b0F)<\/td><\/tr><tr><td>Enclosure<\/td><td>NEMA 4X (Standard), Explosion-proof optional<\/td><\/tr><tr><td>Sensor Material<\/td><td>Noryl<\/td><\/tr><tr><td>Calibration<\/td><td>Annual sensor replacement recommended<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Enhance Your Setup with Wireless Monitoring<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Add the <strong>Wireless Monitoring &amp; Data Logging Kit<\/strong> to your B12 for full remote access via the internet. This add-on allows:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Real-time monitoring from anywhere<\/strong><\/li>\n\n\n\n<li><strong>Instant alerts via text or email<\/strong><\/li>\n\n\n\n<li><strong>Data logging<\/strong> for reporting and compliance<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">It&#8217;s the perfect enhancement for facilities looking to streamline safety protocols and simplify compliance tracking.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If you&#8217;re working in a high-humidity environment and need dependable gas monitoring, the <strong>ATI B12 Wet Gas Transmitter<\/strong> is the solution you&#8217;ve been looking for. With versatile configuration options, durable construction, and the ability to operate in 100% moisture-saturated conditions, it&#8217;s the gold standard for wet gas detection.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/b12-wet-gas-transmitter.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/b12-wet-gas-transmitter.html\">https:\/\/www.gas-sensing.com\/b12-wet-gas-transmitter.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gas detection in high-humidity or wet environments can be a challenge\u2014especially when the air is saturated with water vapor. Traditional gas detectors often fail or [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2363,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[61,32,52,40,41,166,35],"tags":[22,25,34],"class_list":["post-2362","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bromine","category-chlorine","category-chlorine-dioxide","category-hydrogen","category-hydrogen-chloride","category-hydrogen-fluoride","category-ozone","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2362","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2362"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2362\/revisions"}],"predecessor-version":[{"id":2364,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2362\/revisions\/2364"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2363"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2362"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2362"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}