{"id":2469,"date":"2025-07-08T09:00:00","date_gmt":"2025-07-08T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2469"},"modified":"2025-07-09T08:22:10","modified_gmt":"2025-07-09T13:22:10","slug":"c-30zx-ozone-monitor-reliable-fixed-mount-ozone-detection-for-safety-and-control","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/c-30zx-ozone-monitor-reliable-fixed-mount-ozone-detection-for-safety-and-control\/","title":{"rendered":"C-30ZX Ozone Monitor: Reliable Fixed-Mount Ozone Detection for Safety and Control"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>C-30ZX Ozone Monitor<\/strong> is a compact, fixed-mount ozone detector designed for continuous ozone safety monitoring in accordance with <strong>OSHA standards<\/strong>. With a detection range of <strong>0.02 to 0.14 ppm<\/strong>, integrated <strong>audible alarm<\/strong>, <strong>relay control<\/strong>, and <strong>analog output<\/strong>, the C-30ZX is a simple yet powerful tool for facilities that need dependable ozone detection and control.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Key Features of the C-30ZX Ozone Monitor<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Detection Range<\/strong>: Measures ozone levels from 0.02 to 0.14 ppm in 0.02 ppm increments<\/li>\n\n\n\n<li><strong>Visual Display<\/strong>: Multicolor <strong>LED bargraph display<\/strong> that transitions from green (safe) to yellow (caution at 0.05 ppm) and red (danger at 0.10 ppm)<\/li>\n\n\n\n<li><strong>Audible Alarm<\/strong>: Alerts users when ozone levels exceed the set threshold; can be disabled with a front-facing switch<\/li>\n\n\n\n<li><strong>Relay Control<\/strong>: Built-in relay activates simultaneously with the alarm to control equipment or trigger additional safety systems<\/li>\n\n\n\n<li><strong>Analog Output<\/strong>: 0\u20132 VDC output for integration with external systems such as <strong>PLCs<\/strong>, data loggers, or wireless monitoring kits<\/li>\n\n\n\n<li><strong>Response Time<\/strong>: Extremely fast\u2014detects ozone presence in tenths of a second<\/li>\n\n\n\n<li><strong>Maintenance<\/strong>: Minimal upkeep; annual calibration recommended; sensor life is approximately two years<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Benefits<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Real-Time Monitoring<\/strong>: Continuously tracks ozone levels and provides instant feedback with visual and audible alerts<\/li>\n\n\n\n<li><strong>Plug-and-Play<\/strong>: Simple setup with <strong>no installation required<\/strong> for most applications<\/li>\n\n\n\n<li><strong>Compact and Lightweight<\/strong>: Small form factor (3.25&#8243; x 1.375&#8243; x 2.375&#8243;, 5 oz) for easy wall mounting in any facility<\/li>\n\n\n\n<li><strong>User-Adjustable Alarm Setpoints<\/strong>: Customize your alarm and relay triggers from 0.02 to 0.14 ppm using internal DIP switches<\/li>\n\n\n\n<li><strong>Integrated Control<\/strong>: Use the relay output to shut down ozone generators, activate fans, or trigger safety interlocks<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Technical Specifications<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Method<\/strong>: Heated Metal Oxide Semiconductor (HMOS)<\/li>\n\n\n\n<li><strong>Display Type<\/strong>: LED bargraph \u2013 green (normal), yellow (caution), red (danger)<\/li>\n\n\n\n<li><strong>Analog Output<\/strong>: 0\u20133 V for data loggers and monitoring systems<\/li>\n\n\n\n<li><strong>Power Requirement<\/strong>: 12 VDC at 300 mA; AC adapters available<\/li>\n\n\n\n<li><strong>Alarm and Relay Trigger<\/strong>: Default at 0.1 ppm; programmable in 0.02 ppm increments<\/li>\n\n\n\n<li><strong>Outputs<\/strong>: LED display, 0\u20132 VDC analog, relay contacts, audible alarm<\/li>\n\n\n\n<li><strong>Calibration<\/strong>: Annual recommended; includes calibration certificate<\/li>\n\n\n\n<li><strong>Sensor Life<\/strong>: ~2 years (replacement required after failure)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">C-30ZX as a Relay Controller<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>internal relay<\/strong> of the C-30ZX can be configured to activate external systems when ozone reaches the user-defined threshold. This allows automation of ventilation systems, ozone generator shut-off, or activation of visual alarms. DIP switches and terminal connections are easily accessible on the rear of the unit for setup.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">What\u2019s Included<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>C-30ZX Ozone Monitor<\/li>\n\n\n\n<li>AC Power Adapter<\/li>\n\n\n\n<li>User Manual<\/li>\n\n\n\n<li>Calibration Certificate<\/li>\n\n\n\n<li>Wall Bracket with Magnetic Mounting Strip<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Expandability: Data Logging and Remote Monitoring<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Data Logging<\/strong>:<br>Pair the C-30ZX with a <strong>DL-3 data logger<\/strong> to capture ozone concentration readings over time using the 0\u20132 VDC analog output.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wireless Monitoring Kit<\/strong>:<br>Upgrade your system with our <strong>Wireless Monitoring &amp; Data Logging Kit<\/strong> to gain remote access via the internet. Receive <strong>instant alerts via text or email<\/strong> and monitor ozone levels from anywhere.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Ideal Applications<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial workspaces<\/li>\n\n\n\n<li>Laboratories<\/li>\n\n\n\n<li>Cleanrooms<\/li>\n\n\n\n<li>Water treatment facilities<\/li>\n\n\n\n<li>Food processing plants<\/li>\n\n\n\n<li>Any environment where ozone gas is used or generated<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>C-30ZX Ozone Monitor<\/strong> is a cost-effective, reliable solution for maintaining ozone safety and compliance. Whether used for alarm, control, or continuous monitoring, the C-30ZX helps ensure your facility is protected from harmful ozone exposure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/c30zx-ozone-monitor.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/c30zx-ozone-monitor.html\">https:\/\/www.gas-sensing.com\/c30zx-ozone-monitor.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The C-30ZX Ozone Monitor is a compact, fixed-mount ozone detector designed for continuous ozone safety monitoring in accordance with OSHA standards. With a detection range [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2470,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2469","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2469"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2469\/revisions"}],"predecessor-version":[{"id":2471,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2469\/revisions\/2471"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2470"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2469"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2469"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}