{"id":2597,"date":"2025-09-29T09:00:00","date_gmt":"2025-09-29T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2597"},"modified":"2025-09-22T10:16:29","modified_gmt":"2025-09-22T15:16:29","slug":"3-wire-explosion-proof-voc-pro-high-ppm-range-pid-gas-detector","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/3-wire-explosion-proof-voc-pro-high-ppm-range-pid-gas-detector\/","title":{"rendered":"3-Wire Explosion Proof VOC Pro \u2013 High PPM Range PID Gas Detector"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>VOC Pro Series Gas Detector<\/strong> is a <strong>versatile, high-performance gas detection system<\/strong> designed for industrial environments requiring reliable monitoring of volatile organic compounds (VOCs). Equipped with a <strong>Photoionization Detector (PID) sensor<\/strong>, the VOC Pro detects a wide range of gases with high sensitivity and accuracy.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>PID Sensor Options:<\/strong> 10.0 eV lamp \/ 11.7 eV \/ 10.6 eV ppb \/ 10.6 eV ppm<\/li>\n\n\n\n<li><strong>Wired Power:<\/strong> 3-Wire, 12\u201335 VDC operating voltage<\/li>\n\n\n\n<li><strong>Operating Temperature Range:<\/strong> -40\u00b0C to +54\u00b0C<\/li>\n\n\n\n<li><strong>Display:<\/strong> Graphical LCD with LED backlight (102&#215;64 resolution)<\/li>\n\n\n\n<li><strong>Interface:<\/strong> 3 push-buttons (MENU, ADD, SUB) with <strong>magnetic non-intrusive switches<\/strong> for field calibration and system diagnostics<\/li>\n\n\n\n<li><strong>Alarms:<\/strong> Two individually configurable alarms with amber and red LED indicators<\/li>\n\n\n\n<li><strong>Optional Relays:<\/strong> Two fully programmable alarm relays (dry contacts)<\/li>\n\n\n\n<li><strong>Output Options:<\/strong> 4\u201320 mA (3-wire analog) and RS-485 Modbus (4-wire)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>non-intrusive magnetic switches<\/strong> allow users to perform calibration and system diagnostics safely without opening the detector, enhancing safety and simplifying maintenance.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The VOC Pro PID gas detector is suitable for a wide range of industrial applications, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Petrochemical plants<\/strong><\/li>\n\n\n\n<li><strong>Refineries<\/strong><\/li>\n\n\n\n<li><strong>Water &amp; wastewater treatment facilities<\/strong><\/li>\n\n\n\n<li><strong>Pulp &amp; paper mills<\/strong><\/li>\n\n\n\n<li><strong>Manufacturing facilities<\/strong><\/li>\n\n\n\n<li><strong>Automotive industry<\/strong><\/li>\n\n\n\n<li><strong>Semiconductor plants<\/strong><\/li>\n\n\n\n<li><strong>Chemical plants<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Its <strong>high PPM detection range<\/strong> makes it ideal for environments where VOC concentrations may fluctuate significantly, ensuring reliable monitoring and early warning of hazardous conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Specifications<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Sensor Type:<\/strong> PID (Photoionization Detector)<\/li>\n\n\n\n<li><strong>Operating Voltage:<\/strong> Wired 3-Wire, 12\u201335 VDC<\/li>\n\n\n\n<li><strong>Display Screen:<\/strong> 102&#215;64 resolution graphical LCD, transflective with white LED backlight<\/li>\n\n\n\n<li><strong>Interface:<\/strong> 3 push-buttons (MENU, ADD, SUB)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose the VOC Pro Series<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The VOC Pro Series combines <strong>robust construction, explosion-proof design, and versatile sensor options<\/strong> to provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Accurate VOC detection across a <strong>broad range of concentrations<\/strong><\/li>\n\n\n\n<li><strong>Safe operation in hazardous areas<\/strong><\/li>\n\n\n\n<li>Easy calibration and configuration <strong>without disassembly<\/strong><\/li>\n\n\n\n<li>Reliable integration with <strong>analog and digital monitoring systems<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Whether deployed in <strong>petrochemical refineries, chemical plants, or manufacturing facilities<\/strong>, the VOC Pro Series ensures continuous monitoring of hazardous VOCs, keeping personnel and equipment safe.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-high-ppm-range.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-high-ppm-range.html\">https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-high-ppm-range.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The VOC Pro Series Gas Detector is a versatile, high-performance gas detection system designed for industrial environments requiring reliable monitoring of volatile organic compounds (VOCs). [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2598,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[22,25,34],"class_list":["post-2597","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-voc","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2597"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2597\/revisions"}],"predecessor-version":[{"id":2599,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2597\/revisions\/2599"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2598"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}