{"id":2604,"date":"2025-10-01T09:00:00","date_gmt":"2025-10-01T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2604"},"modified":"2025-09-29T09:32:30","modified_gmt":"2025-09-29T14:32:30","slug":"3-wire-explosion-proof-voc-pro-pid-detector-head-low-ppm-range","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/3-wire-explosion-proof-voc-pro-pid-detector-head-low-ppm-range\/","title":{"rendered":"3-Wire Explosion Proof VOC Pro \u2013 PID Detector Head (Low PPM Range)"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>VOC Pro Series Gas Detector<\/strong> is a versatile and robust solution for detecting a wide range of volatile organic compounds (VOCs). Designed for <strong>low PPM detection<\/strong>, this detector features a <strong>PID sensor<\/strong> and an explosion-proof design, making it ideal for use in hazardous industrial environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With flexible <strong>3-wire operation<\/strong>, a graphical LCD, and multiple output options, the VOC Pro allows for precise monitoring and seamless integration into existing safety and process control systems.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>PID Sensor Options:<\/strong>\n<ul class=\"wp-block-list\">\n<li>10.0 eV lamp<\/li>\n\n\n\n<li>11.7 eV lamp<\/li>\n\n\n\n<li>10.6 eV ppb \/ ppm<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Wired 3-Wire Operation:<\/strong> 12\u201335 VDC<\/li>\n\n\n\n<li><strong>Operating Temperature:<\/strong> -40\u00b0C to +54\u00b0C<\/li>\n\n\n\n<li><strong>Display:<\/strong> 102&#215;64 resolution <strong>graphical LCD<\/strong> with white LED backlight<\/li>\n\n\n\n<li><strong>User Interface:<\/strong> 3 push-buttons (MENU, ADD, SUB) with <strong>magnetic, non-intrusive switches<\/strong> for safe field calibration and full system diagnostics<\/li>\n\n\n\n<li><strong>Alarms:<\/strong>\n<ul class=\"wp-block-list\">\n<li>2 individually configurable alarms<\/li>\n\n\n\n<li>2 front panel LED indicators (amber and red)<\/li>\n\n\n\n<li>Optional <strong>fully programmable alarm relays<\/strong> (dry contacts)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Outputs:<\/strong>\n<ul class=\"wp-block-list\">\n<li>4\u201320 mA (3-wire analog)<\/li>\n\n\n\n<li>RS-485 Modbus (4-wire)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The VOC Pro is suitable for a wide variety of industries and environments where VOC detection is critical:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Petrochemical plants<\/li>\n\n\n\n<li>Refineries<\/li>\n\n\n\n<li>Water and wastewater treatment facilities<\/li>\n\n\n\n<li>Pulp and paper mills<\/li>\n\n\n\n<li>Manufacturing operations<\/li>\n\n\n\n<li>Automotive facilities<\/li>\n\n\n\n<li>Semiconductor plants<\/li>\n\n\n\n<li>Chemical plants<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Sensor Type:<\/strong> PID<\/li>\n\n\n\n<li><strong>Operating Voltage:<\/strong> 12\u201335 VDC (wired, 3-wire)<\/li>\n\n\n\n<li><strong>Display:<\/strong> Graphical LCD screen (102&#215;64 resolution) with white LED backlight<\/li>\n\n\n\n<li><strong>Interface:<\/strong> 3 push-buttons (MENU, ADD, SUB) with magnetic, non-intrusive switches<\/li>\n\n\n\n<li><strong>Temperature Range:<\/strong> -40\u00b0C to +54\u00b0C<\/li>\n\n\n\n<li><strong>Outputs:<\/strong> 4\u201320 mA analog, RS-485 Modbus<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose the VOC Pro Series<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>VOC Pro Series<\/strong> combines <strong>high sensitivity, durability, and user-friendly operation<\/strong> in a single explosion-proof package. Magnetic, non-intrusive calibration switches allow technicians to adjust settings safely in the field without exposing the unit to hazardous atmospheres.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With flexible outputs and configurable alarms, the VOC Pro seamlessly integrates into <strong>process control systems<\/strong>, providing continuous monitoring and real-time feedback on VOC levels, helping maintain safety, compliance, and operational efficiency.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>3-Wire Explosion Proof VOC Pro \u2013 PID Detector Head<\/strong> is the ideal choice for any industrial application requiring <strong>accurate, low-level VOC detection in hazardous environments<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-low-ppm-range.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-low-ppm-range.html\">https:\/\/www.gas-sensing.com\/3-wire-explosion-proof-transmitter-voc-pro-pid-detector-head-low-ppm-range.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The VOC Pro Series Gas Detector is a versatile and robust solution for detecting a wide range of volatile organic compounds (VOCs). Designed for low [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2605,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[48],"tags":[22,25,34],"class_list":["post-2604","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-voc","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2604"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2604\/revisions"}],"predecessor-version":[{"id":2606,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2604\/revisions\/2606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2605"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2604"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2604"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}