{"id":2620,"date":"2025-10-08T09:00:00","date_gmt":"2025-10-08T14:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2620"},"modified":"2025-10-06T09:50:20","modified_gmt":"2025-10-06T14:50:20","slug":"a23-14-portable-ozone-generator","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/a23-14-portable-ozone-generator\/","title":{"rendered":"A23-14 Portable Ozone Generator"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Reliable Low-Concentration Ozone for Sensor Calibration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>A23-14 Ozone Generator<\/strong> is a <strong>portable, easy-to-use device<\/strong> designed to produce <strong>low-concentration ozone gas<\/strong> for calibrating ozone sensors in the field or laboratory. With an output of less than <strong>1 PPM<\/strong>, this generator provides a precise ozone standard for <strong>detector calibration<\/strong> in almost any location.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compact and self-contained, the A23-14 is ideal for use with devices such as the <strong>Q45\/65 Dissolved Ozone Monitor<\/strong>, allowing technicians and researchers to verify sensor accuracy wherever needed.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">How It Works<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The A23-14 operates using <strong>ultraviolet (UV) light technology<\/strong>. Dry air from a <strong>compressed air cylinder<\/strong> is supplied to a UV cell, where a small amount of ozone is generated. The resulting air-ozone mixture exits the generator through <strong>fluorocarbon outlet tubing<\/strong>, which can be connected directly to the sensor being calibrated.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Simple Operation Steps:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Plug the UV generator cell into any convenient power outlet.<\/li>\n\n\n\n<li>Open the cylinder valve to supply air to the generator. The cylinder includes a <strong>fixed flow regulator<\/strong>, so no additional flow adjustment is required.<\/li>\n\n\n\n<li>Connect the outlet tubing to your ozone sensor.<\/li>\n\n\n\n<li>Calibrate the sensor for the desired period.<\/li>\n\n\n\n<li>Shut off the system when calibration is complete.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Each A23-14 generator produces a nominal ozone concentration of <strong>approximately 0.8 PPM<\/strong>, but each unit is individually tested and marked with its <strong>accurate ozone concentration<\/strong> prior to shipment for precise calibration.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Portable and Compact:<\/strong> Easily transported for field or laboratory use.<\/li>\n\n\n\n<li><strong>Low-Concentration Ozone Output:<\/strong> Less than 1 PPM, ideal for sensor calibration.<\/li>\n\n\n\n<li><strong>UV-Based Ozone Generation:<\/strong> Reliable and stable ozone production.<\/li>\n\n\n\n<li><strong>Simple Operation:<\/strong> Plug in and open the air cylinder\u2014no complex controls required.<\/li>\n\n\n\n<li><strong>Individually Calibrated:<\/strong> Each generator is marked with its verified ozone concentration.<\/li>\n\n\n\n<li><strong>Durable Case:<\/strong> Molded case includes storage for the generator, air cylinder, tubing, and calibration adapters.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Kit Contents<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The standard A23-14 kit includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Portable UV ozone generator<\/li>\n\n\n\n<li><strong>103-liter compressed air cylinder<\/strong> with fixed flow regulator<\/li>\n\n\n\n<li><strong>3 feet of outlet tubing<\/strong><\/li>\n\n\n\n<li>Durable molded case for transport and storage<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This setup provides a <strong>complete portable calibration solution<\/strong>, ensuring that your ozone sensors are always accurate and reliable.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The A23-14 is perfect for a variety of <strong>ozone calibration and verification tasks<\/strong>, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Field calibration of dissolved ozone monitors<\/li>\n\n\n\n<li>Laboratory verification of ozone detectors<\/li>\n\n\n\n<li>Routine maintenance and sensor quality assurance<\/li>\n\n\n\n<li>Mobile testing where low-concentration ozone standards are required<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>A23-14 Portable Ozone Generator<\/strong> is a <strong>user-friendly, reliable, and precise tool<\/strong> for low-concentration ozone calibration. Its portability, UV-based generation, and pre-calibrated output make it an ideal choice for technicians, laboratories, and field applications requiring consistent and accurate ozone sensor calibration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether in a lab, industrial setting, or remote location, the A23-14 provides <strong>precision ozone generation wherever you need it<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">You can find this product here: <a href=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\" data-type=\"link\" data-id=\"https:\/\/www.gas-sensing.com\/a23-14-calibrator.html\">https:\/\/www.gas-sensing.com\/a23-14-calibrator.html<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Reliable Low-Concentration Ozone for Sensor Calibration The A23-14 Ozone Generator is a portable, easy-to-use device designed to produce low-concentration ozone gas for calibrating ozone sensors [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":2621,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[22,25,34],"class_list":["post-2620","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-gas-monitoring","tag-gas-safety","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2620"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2620\/revisions"}],"predecessor-version":[{"id":2622,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2620\/revisions\/2622"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2621"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2620"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2620"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}