{"id":2974,"date":"2025-12-31T09:00:00","date_gmt":"2025-12-31T15:00:00","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=2974"},"modified":"2025-12-31T09:01:09","modified_gmt":"2025-12-31T15:01:09","slug":"understanding-uv-absorption-technology-for-gas-measurement","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/understanding-uv-absorption-technology-for-gas-measurement\/","title":{"rendered":"Understanding UV Absorption Technology for Gas Measurement"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Reliability<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV absorption<\/a> technology is one of the most reliable methods for measuring gas concentrations in a wide range of applications. This approach works on a straightforward principle: gases absorb ultraviolet light at specific wavelengths. By sending UV light through a sample and measuring how much is absorbed, an analyzer can determine the exact concentration of the gas present.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Precision<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">What makes <a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">UV absorption<\/a> especially useful is its precision. It\u2019s not influenced by humidity, temperature shifts, or the presence of most other gases, which helps ensure stable and accurate readings. This durability also means the system requires less frequent maintenance than many other measurement methods.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Flexibility<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Another advantage is its flexibility.<a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html\"> UV analyzers<\/a> can be configured for low-level or high-concentration environments, making them valuable for industries that need dependable, continuous monitoring. Because the technology is based on optical measurement rather than chemical reactions, it offers long-term reliability without consumables or frequent calibration.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter is-resized\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/downloads\/Images\/UV_Ozone_Analyzer_operation.png\" alt=\"UV analyzer setup Oxidation Technologies and Gas Sensing\" style=\"aspect-ratio:0.8034864659549799;width:486px;height:auto\" \/><\/a><figcaption class=\"wp-element-caption\">Similar UV Analyzer Setup for Ozone <\/figcaption><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/www.oxidationtech.com\/ozone\/ozone-system-design\/ozone-measurement-using-uv-absorption-analyzers.html\">Oxidation Technologies<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">How It Works<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>A sample of the gas is drawn into a chamber, where a UV light source shines through it at a specific wavelength.<\/li>\n\n\n\n<li>If the target gas is present, it absorbs part of that UV light. The more gas present, the more light is absorbed.<\/li>\n\n\n\n<li>By comparing the light intensity before and after it passes through the chamber, the analyzer calculates the gas concentration using a predictable absorption relationship.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/www.oxidationtech.com\/products\/ozone-monitors\/uv-analyzer.html\">UV Analyzer<\/a> Products<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#uv-low-range-ozone-analyzers\">Low Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#uv-medium-range-ozone-analyzers\">Medium Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#uv-high-range-ozone-analyzers\">High Range<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#calibration-source\">Calibration Source<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#measure-ozone-in-water\">Measure O3 in Water<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.gas-sensing.com\/ozone-products\/uv-analyzer.html#rental-ozone-analyzers\">Rental O3 Analyzers<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\">In short, UV absorption provides a clear, stable, and efficient way to measure gas concentrations\u2014ideal for operations that depend on accuracy and consistency.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left\">General <a href=\"https:\/\/www.gas-sensing.com\/calibration\">Calibration <\/a>Information<\/h2>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">All Gas Sensors will require periodic <a href=\"https:\/\/www.gas-sensing.com\/calibration\">calibration <\/a>to ensure your gas measurements are accurate and correct.&nbsp; Different gasses, and sensor manufacturers will have differing requirements and methods for calibration.&nbsp; This page will serve to provide general <a href=\"https:\/\/www.gas-sensing.com\/calibration\">calibration <\/a>information and links to specific <a href=\"https:\/\/www.gas-sensing.com\/calibration\">calibration <\/a>procedures from the sensor manufacturers we represent.<\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Should you have any questions about sensor <a href=\"https:\/\/www.gas-sensing.com\/calibration\">calibration<\/a>, or would like us to help you with your calibrations&nbsp;<a href=\"https:\/\/www.gas-sensing.com\/contact-us\">please contact us.<\/a><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><div class=\"aligncenter wp-block-site-logo\"><a href=\"https:\/\/www.gas-sensing.com\/news\/\" class=\"custom-logo-link\" rel=\"home\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"104\" src=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2018\/11\/logo-600x109.png\" class=\"custom-logo\" alt=\"\" srcset=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2018\/11\/logo.png 1014w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2018\/11\/logo-300x54.png 300w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2018\/11\/logo-768x139.png 768w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2018\/11\/logo-600x109.png 600w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/www.oxidationtech.com\/media\/logo\/stores\/5\/oxidationtech-logo2.png\" alt=\"Oxidation Technologies\" style=\"aspect-ratio:4.688012582855859;width:389px;height:auto\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.oxidationtech.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">Oxidation Technologies<\/a><\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">We offer additional gas detection products in partnership with our subsidiary,&nbsp;<a href=\"http:\/\/Oxidationtechnologies.com\" data-type=\"link\" data-id=\"Oxidationtechnologies.com\" target=\"_blank\" rel=\"noreferrer noopener\">Oxidation Technologies<\/a>.&nbsp;&nbsp;This post derives information from <a href=\"http:\/\/Oxidationtechnologies.com\">Oxidation Technologies<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Reliability UV absorption technology is one of the most reliable methods for measuring gas concentrations in a wide range of applications. This approach works on [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":2977,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[2,314,328],"tags":[339,119,34,338,334,337],"class_list":["post-2974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gas-sensing","category-gas-solutions","category-uv-absorption-ozone-analyzer","tag-gas-measurement","tag-gas-sensing","tag-gas-sensing-product","tag-uv-absorption","tag-uv-absorption-ozone-analyzer","tag-uv-light"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=2974"}],"version-history":[{"count":6,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2974\/revisions"}],"predecessor-version":[{"id":3118,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/2974\/revisions\/3118"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/2977"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=2974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=2974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=2974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}