{"id":3425,"date":"2026-09-09T08:32:46","date_gmt":"2026-09-09T13:32:46","guid":{"rendered":"https:\/\/www.gas-sensing.com\/news\/?p=3425"},"modified":"2026-09-01T08:48:07","modified_gmt":"2026-09-01T13:48:07","slug":"used-uv-106-m-ozone-analyzer-affordable-reliable-ozone-measurement","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/used-uv-106-m-ozone-analyzer-affordable-reliable-ozone-measurement\/","title":{"rendered":"Used UV-106-M Ozone Analyzer: Affordable, Reliable Ozone Measurement"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">For laboratories, research facilities, and industrial applications that require accurate ozone monitoring, a used <strong>UV-106-M Ozone Analyzer<\/strong> can provide a cost-effective alternative to purchasing new equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/www.gas-sensing.com\/uv-106-m-ozone-analyzer-used.html\">UV-106-M<\/a> uses <strong>ultraviolet (UV) absorption technology<\/strong> to measure ozone concentration across a range of <strong>0 to 1,000 ppm<\/strong>, with <strong>0.01 ppm resolution<\/strong>. Its combination of sensitivity, measurement range, and compact design makes it suitable for a variety of ozone monitoring applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Features<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The UV-106-M offers several features that make it a versatile ozone analyzer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>0\u20131,000 ppm ozone measurement range<\/strong><\/li>\n\n\n\n<li><strong>0.01 ppm resolution<\/strong><\/li>\n\n\n\n<li>UV absorption measurement technology<\/li>\n\n\n\n<li>Integrated sample pump<\/li>\n\n\n\n<li>Internal data logging and real-time clock<\/li>\n\n\n\n<li>USB and RS-232 communication<\/li>\n\n\n\n<li>Selectable <strong>0\u20132.5 V and 4\u201320 mA<\/strong> analog outputs<\/li>\n\n\n\n<li>Two-level relay control<\/li>\n\n\n\n<li>Compact bench-mount design<\/li>\n\n\n\n<li>Approximately 10-second response time<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ozone analyzers such as the UV-106-M can be used in applications including <strong>ozone generation, water and wastewater treatment, laboratory research, environmental monitoring, industrial processes, and process control<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The analyzer&#8217;s analog outputs and relay controls also allow it to be integrated into larger monitoring or control systems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why Consider Used Equipment?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Used analytical equipment can be a practical choice for organizations looking to reduce equipment costs while maintaining access to professional measurement capabilities. A properly tested, calibrated, and maintained used analyzer can be well suited for research projects, additional monitoring stations, replacement equipment, or process applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When purchasing used equipment, it is important to verify the instrument&#8217;s <strong>condition, calibration status, warranty, and included accessories<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conclusion<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The used <strong><a href=\"https:\/\/www.gas-sensing.com\/uv-106-m-ozone-analyzer-used.html\">UV-106-M Ozone Analyzer<\/a><\/strong> offers a combination of broad measurement range, high resolution, UV absorption technology, data logging, and flexible connectivity. For users who need dependable ozone measurement without the cost of new equipment, a professionally tested used analyzer can be an effective and economical option.<\/p>\n\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/www.gas-sensing.com\/uv-106-m-ozone-analyzer-used.html\"><img decoding=\"async\" src=\"https:\/\/www.gas-sensing.com\/media\/catalog\/product\/cache\/74c1057f7991b4edb2bc7bdaa94de933\/s\/c\/screenshot_2022-04-11_133524_2_1.png\" alt=\"UV-106\" style=\"width:357px;height:auto\" title=\"UV-106\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>For laboratories, research facilities, and industrial applications that require accurate ozone monitoring, a used UV-106-M Ozone Analyzer can provide a cost-effective alternative to purchasing new [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":3362,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[35,554,555,565,328],"tags":[754,220,128,601,753],"class_list":["post-3425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ozone","category-ozone-detection","category-ozone-monitors","category-used-equipment","category-uv-absorption-ozone-analyzer","tag-analyzer","tag-ozone-analyzer","tag-ozone-monitor","tag-used-analyzer","tag-uv-106m"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/3425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=3425"}],"version-history":[{"count":1,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/3425\/revisions"}],"predecessor-version":[{"id":3426,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/3425\/revisions\/3426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/3362"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=3425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=3425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=3425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}