{"id":50,"date":"2016-10-05T20:09:29","date_gmt":"2016-10-05T20:09:29","guid":{"rendered":"http:\/\/www.gas-sensing.com\/news\/?p=50"},"modified":"2016-11-29T16:41:39","modified_gmt":"2016-11-29T22:41:39","slug":"auto-test-generators-for-the-d12","status":"publish","type":"post","link":"https:\/\/www.gas-sensing.com\/news\/auto-test-generators-for-the-d12\/","title":{"rendered":"Auto Test Generators for the D12"},"content":{"rendered":"<p>The <a href=\"https:\/\/www.gas-sensing.com\/d-12-toxic-gas-transmitter.html\">D12 Toxic Gas Transmitter<\/a> has the option to add an auto-test generator, which verifies the function of the transmitter.<\/p>\n<figure id=\"attachment_52\" aria-describedby=\"caption-attachment-52\" style=\"width: 150px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-52 size-thumbnail\" src=\"https:\/\/www.gas-sensing.com\/wp\/wp-content\/uploads\/sites\/2\/2016\/09\/Auto-Test-Generator-150x150.png\" alt=\"Auto test generator for chlorine, ammonia, carbon monoxide, hydrogen sulfide, sulfur dioxide\" width=\"150\" height=\"150\" \/><figcaption id=\"caption-attachment-52\" class=\"wp-caption-text\">Auto test generator for chlorine, ammonia, carbon monoxide, hydrogen sulfide, sulfur dioxide<\/figcaption><\/figure>\n<p>The way the auto-test generator functions is a small amount of gas is exposed to the sensor to verify that it will react. This is set up on a prearranged schedule and three attempts are made to verify response. If the sensor does not respond on the third attempt, a fault alarm is triggered.\u00a0 The test is performed at a specific time of day (that is user set and can be changed to best fit your schedule), and can be schedule to repeat every 1 to 14 days.\u00a0 The auto test can also be triggered manually at any time and will not affect the set schedule.\u00a0 This is a great way to ensure that you sensor is still working accurately and that in an emergency situation, that the sensor would detect the hazardous gas.<\/p>\n<figure id=\"attachment_53\" aria-describedby=\"caption-attachment-53\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.gas-sensing.com\/d-12-toxic-gas-transmitter.html\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-53 size-medium\" src=\"https:\/\/www.gas-sensing.com\/wp\/wp-content\/uploads\/sites\/2\/2016\/09\/D12-connecting-sensor-generator-holder-300x294.png\" alt=\"This shows how the sensors and auto-test generator is connected to the D12.\" width=\"300\" height=\"294\" srcset=\"https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2016\/09\/D12-connecting-sensor-generator-holder-300x294.png 300w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2016\/09\/D12-connecting-sensor-generator-holder-768x754.png 768w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2016\/09\/D12-connecting-sensor-generator-holder-624x612.png 624w, https:\/\/www.gas-sensing.com\/news\/wp-content\/uploads\/sites\/2\/2016\/09\/D12-connecting-sensor-generator-holder.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-53\" class=\"wp-caption-text\">This shows how the sensors and auto-test generator is connected to the D12.<\/figcaption><\/figure>\n<p>The Auto-Test Generator can be easily added at any time to the standard integral sensor holder on the D12.\u00a0 The Auto-Test unit is available in 5 types; <a href=\"https:\/\/www.gas-sensing.com\/c18-11-chlorine-gas-generator-00-1239.html\">Chlorine<\/a>, <a href=\"https:\/\/www.gas-sensing.com\/c18-15-ammonia-gas-generator-00-1240.html\">Ammonia<\/a>, <a href=\"https:\/\/www.gas-sensing.com\/c18-16-carbon-monoxide-gas-generator-00-1241.html\">Carbon Monoxide<\/a>, <a href=\"https:\/\/www.gas-sensing.com\/c18-24-hydrogen-sulfide-gas-generator-00-1243.html\">Hydrogen Sulfide<\/a>, and <a href=\"https:\/\/www.gas-sensing.com\/c18-27-sulfur-dioxide-gas-generator-00-1244.html\">Sulfur Dioxide<\/a> but can be used with the a few different types of sensors.\u00a0 See the table below for the compatible generators and sensors:<\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><strong>Auto-test Generator \u00a0<span class=\"Apple-converted-space\">\u00a0<\/span><\/strong><\/td>\n<td><strong>Generator Type\u00a0 \u00a0 \u00a0\u00a0\u00a0<span class=\"Apple-converted-space\">\u00a0<\/span><br \/>\n<\/strong><\/td>\n<td><strong>Compatible Sensors \u00a0 \u00a0<span class=\"Apple-converted-space\">\u00a0<\/span><br \/>\n<\/strong><\/td>\n<\/tr>\n<tr>\n<td><a title=\"00-1239\" href=\"https:\/\/www.gas-sensing.com\/c18-11-chlorine-gas-generator-00-1239.html\" target=\"_blank\">00-1239<\/a><\/td>\n<td>Chlorine (Cl2)\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<span class=\"Apple-converted-space\">\u00a0<\/span><\/td>\n<td>Bromine (Br2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Chlorine (Cl2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Chlorine Dioxide (ClO2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Flourine (F2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Ozone (O3)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Hydrogen Flouride (HF)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Nitrogen Dioxide (NO2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Iodoine (I2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Acid Gas<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a title=\"00-1240\" href=\"https:\/\/www.gas-sensing.com\/c18-15-ammonia-gas-generator-00-1240.html\" target=\"_blank\">00-1240<\/a><\/td>\n<td>Ammonia (NH3)<\/td>\n<td>Ammonia (NH3)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Dimethylamine (DMA)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a title=\"00-1241\" href=\"https:\/\/www.gas-sensing.com\/c18-16-carbon-monoxide-gas-generator-00-1241.html\" target=\"_blank\">00-1241<\/a><\/td>\n<td>Carbon Monoxide (CO)<\/td>\n<td>Carbon Monoxide (CO)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a title=\"00-1243\" href=\"https:\/\/www.gas-sensing.com\/c18-24-hydrogen-sulfide-gas-generator-00-1243.html\" target=\"_blank\">00-1243<\/a><\/td>\n<td>Hydrogen Sulfide (H2S)<\/td>\n<td>Hydrogen Sulfide (H2S)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Hydrogen Chloride (HCl)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a title=\"00-1244\" href=\"https:\/\/www.gas-sensing.com\/c18-27-sulfur-dioxide-gas-generator-00-1244.html\" target=\"_blank\">00-1244<\/a><\/td>\n<td>Sulfer Dioxide (SO2)<\/td>\n<td>Sulfer Dioxide (SO2)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>Hydrogen Cyanide (HCN)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The D12 Toxic Gas Transmitter has the option to add an auto-test generator, which verifies the function of the transmitter. The way the auto-test generator [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":52,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[3,29,32,2,30,31],"tags":[33,8,22,34],"class_list":["post-50","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ammonia","category-carbon-monoxide","category-chlorine","category-gas-sensing","category-hydrogen-sulfide","category-sulfure-dioxide","tag-d12-auto-test-generator","tag-gas-detection-device","tag-gas-monitoring","tag-gas-sensing-product"],"_links":{"self":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/50","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/comments?post=50"}],"version-history":[{"count":2,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/50\/revisions"}],"predecessor-version":[{"id":54,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/posts\/50\/revisions\/54"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media\/52"}],"wp:attachment":[{"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/media?parent=50"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/categories?post=50"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gas-sensing.com\/news\/wp-json\/wp\/v2\/tags?post=50"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}