Model 465L UV Photometric Ozone Monitor: Precision Ozone Detection for Critical Applications

When it comes to monitoring ozone levels in sensitive environments, precision and reliability are non-negotiable. The Model 465L UV Photometric Ozone Monitor stands out as an exceptional instrument for low-level ozone safety and process applications, delivering robust performance, advanced diagnostics, and industry-leading accuracy.

Designed for environments where even trace levels of ozone must be closely monitored—such as laboratories, semiconductor facilities, and cleanrooms—the 465L offers cutting-edge features backed by NIST-traceable calibration and sophisticated pressure and temperature compensation.


Reliable Performance, Unmatched Accuracy

The Model 465L uses the UV absorption method based on the Beer-Lambert Law, a highly stable and accurate technique for measuring ozone. With a lower detectable limit (LDL) of just 3 ppb, it is ideal for applications that demand ultra-low detection capabilities.

Standard temperature and pressure compensation ensure that your measurements remain accurate regardless of ambient conditions. The instrument also boasts minimal zero drift (as low as 0.005 ppm/month), ensuring consistent long-term operation with reduced need for recalibration.


Flexible Configuration Options

The 465L is available in two enclosure styles:

  • 19″ Rack Mount for clean, space-efficient installation in control rooms
  • NEMA 4X Wall Mount for harsh or outdoor environments

It can be configured as a single-stream unit or upgraded to a multi-stream system monitoring up to six individual sample lines, making it scalable for large facilities or multi-zone safety applications.


User-Friendly Interface and Remote Access

With menu-driven software, operators can easily configure and calibrate the device in the field. The 465L’s graphical display shows real-time test values and system warnings, while built-in diagnostics continuously monitor performance and provide alerts if conditions fall outside safe operating ranges.

Every front-panel function is also accessible remotely via the RS-232 port, and optional Ethernet connectivity enables integration into modern digital monitoring systems.


Key Features at a Glance

  • NIST-Traceable UV Absorption Technology
  • LDL: 3 ppb
  • Pressure and Temperature Compensation (Standard)
  • Fast Response Time: <30 seconds to 95%
  • Minimal Zero Drift
  • 1, 3, or 6 Sample Stream Versions Available
  • Menu-Driven Interface with Graphical Display
  • Optional Ethernet Connectivity
  • Built-In Diagnostics and Self-Check Alarms
  • Programmable Alarms with Latching/Non-Latching Relays
  • Wide Range of Output Units: ppmv, ppbv, μg/m³, etc.

Technical Specifications

  • Measuring Range: 0–1 ppm to 0–500 ppm
  • Repeatability/Precision: ±0.5% of full scale
  • Display Resolution: 0.001 ppm
  • Sample Flow Rate: 0.8 L/min
  • Response Time: <30 seconds (to 95%)
  • Operating Temp: 5–45°C
  • Power Supply: 100–240 VAC, 50/60 Hz
  • Analog Output: 4–20 mA, 5V, or isolated
  • Digital Output: RS-232 (57.6 Kbaud), Optional Ethernet
  • Dimensions:
    • Rack Mount: 5.22″ x 19″ x 15.3″
    • NEMA 4X: 16.01″ x 15.77″ x 8.02″
  • Weight:
    • Rack Mount: 13.6 lbs
    • NEMA 4X: 15.1 lbs

Maintenance Tip: Replace Filters Regularly

To ensure continued accuracy and avoid contamination, it is essential to replace the filter frequently. This prevents particulate matter from entering the sample flow path and degrading performance.

Recommended Product: FILTERHS – Compatible filter housing for the Model 465L.


Conclusion

The Model 465L UV Photometric Ozone Monitor is the ideal solution for critical ozone monitoring in low-level safety and process control applications. With flexible installation options, superior measurement stability, and easy remote integration, the 465L ensures you stay in control of your air quality data—no matter the challenge.

You can find this product here: https://www.gas-sensing.com/api465l.html