Search results for: 'ozone'

Loading...
  • Gas-Sensing is a partner company to Oxidation Technologies, LLC.   Oxidation Technologies provides services and products exclusively to the ozone industry.  For all ozone related inquiries please refer to Oxidation Technologies.   What is Ozone? The oxygen atom is unstable in the atomic form. Oxygen is stable in the diatomic form as O2. The air we breath today is made up of about 21% oxygen, this makes oxygen one of the most common molecules found in nature today. Ozone is a triato...
  • The chart below shows various materials resistance to ozone oxidation.  This chart should be used as a reference only.  Some materials will be affected by ozone differently in wet, or dry conditions.  Also, materials will react differently with higher or lower ozone concentrations .  If you have questions about the materials used in your application, contact us , we would be glad to help.  A = Excellent - no effect from ozone in normal operation B = Good - some oxidati...
  • This information is specific to the A-21ZX as it is the most popular ozone sensor EcoSensors sells.  While the general information found in this article are specific to the A-21ZX, the technical aspects are the same for the EZ-1X, C-30ZX, and OS-1X sensors.  Should you have any questions about the details of your sensor please contact Gas Sensing . Replacement sensors are available from Gas Sensing for $75.  The same sensor is used in the A-21ZX, C-30ZX, EZ-1X, and OS-1X Devices. ...
  • Tech note from EcoSensors The Eco Sensors UV-100 calibration can be fairly accurately monitored using the Eco Sensors OG-3 Calibration Checker if the calibration of the OG-3 is checked and adjusted for accuracy at the user's altitude. The OG-3 is calibrated in Eco Sensors' laboratory at 2,100 meters. At lower altitudes the OG-3 will generate ozone at a slightly higher concentration than the standard .1 ppm due to the higher molecular density of air at lower altitudes. This difference in OG-3 outpu...
  •   ATI Technical Documents   F12 Enclosure dimensions and technical drawings D12 Enclosure dimensions and technical drawings     EcoSensors Technical Documents Ozone Use for air quality in Casino - Case Study UL Ozone Safety Standards Ozone monitoring and control for air treatment systems Ozone Safety Standards Ozone measurement in fire restoration applications Ozone sensor suggestions for cold storage applications ...
  • General Calibration Information All Gas Sensors will require periodic calibration to ensure your gas measurements are accurate and correct.  Different gasses, and sensor manufactrers will have differeing requirements and methods for calibration.  This page will serve to provide general calibration information and links to specific calibration procedures from the sensor manufacturers we represent. Should you have any questions about sensor calibration, or would like us to help you with your ...
  • Analytical Technologies Incorporated (ATI) This information applies to the sensor module used in the C16 , F12 , and D12 Monitors. ATI Smart Sensors come pre-calibrated and have all calibration information loaded on the sensor.  The sensor can be swapped between monitors without any special requirements for proper calibration. Sensors are fairly low cost and are replaced annually to remain in calibration.  Periodic bump tests can be performed to ensure the sensor is still ope...
  • About Gas-Sensing.com Our purpose is to provide quality gas monitoring products to satisfy all of your safety and control needs!   Who we are... Gas-Sensing.com was originally founded by Mark Bosma and Joel Leusink, to fill the needs of customers that went beyond just ozone monitoring.  This quickly turned into a larger vision, expanding to online sales and a wider audience. What we sell... Please feel free to browse our website, compare products, and con...
  • Our purpose is to provide quality gas monitoring products to satisfy all of your safety and control needs!     Manufacturers we Represent Who we are... Gas-Sensing.com was originally founded by Mark Bosma and Joel Leusink, to fill the needs of customers that went beyond just ozone monitoring.  This quickly turned into a larger vision, expanding to online sales and a wider audience. What we sell... Please feel free to browse our website, compare ...
  • Aeroqual Aeroqual SM-70 Controller Aeroqual Series-100 Controller Aeroqual Series-200 Monitor Quick Start Guide Aeroqual Series-200 Monitor User Manual Aeroqual Series-300 Monitor Quick Start guide Aeroqual Series-300 Monitor User Manual Aeroqual Series-500 Monitor Quick Start guide Aeroqual Series-500 Monitor User Manual Aeroqual Series-320 Monitor User Manual Aeroqual Series-520 Monitor User Manual Aeroqual Series-900 Controller/Transmitter Aer...
  • Aeroqual Aeroqual Series-100 Specification Sheet Aeroqual Series-200 Specification Sheet Aeroqual Series-300 Specification Sheet Aeroqual Series-500 Specification Sheet Aeroqual Series-900 Specification Sheet Aeroqual SM-70 Specification Sheet Aeroqual Sensor Specifcations UV-H Ozone Analyzer Specifications Series-960 Ozone Analyzer Specifications UV-1 OEM Ozone Analyzer Specifications UV-1 OEM Ozone Analyzer Brochure     Analytic...
  • Gas Information Information on gasses and what monitor may be right for you can be found at the links below. Ammonia   Carbon Monoxide     Hydrogen Sulfide   Nitrogen Dioxide   Ozone   Perchloroethylene     Volatile Organic Compound (VOC)   Manuals Find operation manuals here       Specif...
  • Volatile Organic Compound (VOC): What is VOC: Volatile Organic Compounds, more commonly known as VOC's consist of a wide variety of organic compounds that are vapor at room temperature.  Many different gasses may make up VOC's, and some of those gasses may also be associated with other families of gasses.  A complete list of VOC's can be found at the bottom of this page. Health Risks of VOC's: VOC's can cause respiratory, allergic, or immune effects...
  • Aeroqual Portable Monitors Calibrations FAQ This technical information on this page is relevant for the Handheld Series-200, 300, 500, and Fixed Mount Series-900, 930, 940.  For information on the SM-70 and SM-50 scroll to the bottom of this page. 1. What do I calibrate - the monitor or the sensor head? Aeroqual’s unique system of interchangeable sensor heads means they can be calibrated independently of the monitor. If you are sending a sensor head to us for f...
  • EcoSensors devices have a variety of different sensors and calibration options and prodedures.  These will vary by product and sensor used in that product.  See the list below for your specific sensor and relevant calibration information.  First, follow our short list of FAQ's to familirize yourself with general calibration inforamtion. EcoSensors FAQ and General Information Will I get a Calibration Certificate? Yes, all EcoSensors products are shipped with a recent calibratio...
  • This document refers to the C-21 and earlier EcoSensors VOC Instruments Replacement sensors for the C-21 are available from Gas Sensing for $50.  Please contact us for ordering information. The Eco Sensors C-21 responds to most reducing VOCs, but not with the same degree of response for each VOC. The response is essentially logarithmic. For the first half of the scale (to about the 2nd yellow bar), the response is approximately linear. After that, it gets sharply logarithmic (much more c...
  • The Portasens is known as a great ambient air portable gas leak detector that features: - electrochemical smart-cell sensor (which can be calibrated independently of the unit) - available to measure over 30 types of gases - a rugged internal sample pump - excellent accuracy and repeatability - easy to read back-lit LED display - flexible wand for pinpointing leak points - datalogging capabilities - integrated audible alarms Because of the many attractive features a...
  • Non-Methane Hydrocarbons: What are NMHCs: Non-Methane Volatile Organic Compounds (NMVOCs) are a large variety of chemically different compounds such as benzene, ethanol, formaldehyde, cyclohexane, and acetone. NMVOCs are essentially identical to VOCs , with the exlusion of methane. An important subset of NMVOCs are NMHCs. NMHCs are trace atmospheric components that provide a sink for hydroxyl radicals and control ozone concentration. Exmples of NMHCs are ethane, ethene, propane, pro...
  • 1 - Remove back of UV-100. 2 - Gently pull out right hand circuit board releasing any cable and tubing connectors that may be required to release the board. Note where these connections were. Also note that this circuit board goes in the 8th enclosure slot (top and bottom) from the right. 3 - Find the 11 cm X 6 cm X 3 cm black plastic block on the circuit board and remove the screws holding it to the board. Note which connector mated with which connector such as by uniquely coloring a dot on each wit...
  • We provide Gas Sensors for every workplace, or safety need. Gas sensors for leak detection Work place safety alarm Personal safety sensor Hazardous location sensor UV Analyzers OEM Solutions Contact us to help you choose the right Sensor for your application: 605-368-1404 sales@gas-sensing.com Portable Gas Sensors Fixed Mount Gas Sensors Re...