Glutaraldehyde ChromAir Badge

ChromAir chemical exposure badges are a color indicating making them easy to use and perfect for monitoring personnel safety.

Quantity = 10 badges  clips are NOT included

Note: we are not able to ship these badges outside of the US

Shipping Note: We now only ship the Glutaraldehyde badges Monday – Wednesday 2nd Day air. Since we only ship them those days, they do not require a cooler pack for transport. But badges should be refrigerated after receipt.

Glutaraldehyde Information

SKU
M 380017-10
  $187.00

Related Products

Description / Glutaraldehyde ChromAir Badge

Color change for Glutaraldehyde is from pink to violet.

The ChromAir Glutaraldehyde badge may be used for personnel or area monitoring for exposure times of 15 minutes.

 

Introduction:

Glutaraldehyde is a colorless liquid with an irritating odor. It has an odor threshold in the ppb level. Glutaraldehyde may be fatal if inhaled, swallowed or absorbed through the skin. Symptoms of exposure may include burning sensations, coughing, shortness of breath, headache, nausea and vomiting. To the best of our knowledge, toxicological, chemical and physical properties have not been thoroughly studied. OSHA and NIOSH STEL are 0.2 ppm. Glutaraldehyde is used extensively in the medical field. It is used in hospitals for cold sterilization of medical supplies and instruments.

Glutaraldehyde is also used as a disinfectant in urology, endoscopy and dental departments.

 

Principle of Operation:

The ChromAir passive monitor is a patented direct-read autogenic exposimeter. The device is constructed from six cells attached on one side to a flat indicator layer and on the other side to a series of different diffusive resistances. Carbon monoxide gas diffuses to the cells through the different diffusive resistances and reacts with the indicator layer, producing color change from light brown to brown to black. The color produced on the indicator layer is a direct measure of the exposure dose. Visual color comparison is achieved by observing the formation of the brown threshold color on the individual cell and reading the corresponding exposure dose.

Direct Read Color Comparator Safety Monitor

Pictured above is the additional color comparator that is used for higher resolutions and accuracy (available for Carbon Monoxide, Formaldehyde, Mercury).

 

Operating Instructions:

1. Remove the pouch from refrigerator and allow it to warm to room temperature.

2. Remove the badge from its protective pouch.

3. Enter all pertinent information on the I.D. label before monitoring is started (i.e. name, location, date and start time).

4. Prior to exposure, remove the protective strip from the first cell on the front of the badge.

5. For personnel monitoring, attach the badge near the user's breathing zone (i.e. collar) with the front side exposed to the surrounding atmosphere.

6. For area monitoring, attach the badge to a stand and mount in a centralized area with the front side exposed to the surrounding atmosphere.

7. Check the back side of the badge periodically to determine the exposure dose (ppm•hr).

8. To read the badge, locate the highest level cell with brown threshold color.

9. To obtain the average concentration (ppm) in the surrounding atmosphere, divide the exposure dose (ppm•hr) by the exposure time in hours.

EXAMPLE: If the sampling time is 2 hours and the badge reads 10 ppm•hr, the average conc

 

Storage:

The ChromAir STEL glutaraldehyde monitor should be refrigerated in its sealed bag at all times.

 

Sampling Parameters:

Color Change

pink to violet

Exposure range (Badge)

0.04 - 0.95 ppm

Relative humidity range

25% - 85%

Face velocity range

10 - 165 cm/sec

Temperature range

15ºC - 35ºC (59ºF - 95ºF)

Mean coefficient of variation

+/- 6.8

Bias at ambient conditions

 -1.4 %

Light effect - UV (direct sunlight)

no effect

Light effect - visible

no effect

Refrigerated shelf life

 1 year

 

Downloads:

380017 Manual

Glutaraldehyde Information

More Information

Manufacturer Morphix
Gas Glutaraldehyde
Standard Range 0.04 - 0.95 PPM
Operational Temperature Range 15ºC - 35ºC (59ºF - 95ºF)
Operational RH Range 25% - 85%
Audible Alarm No
Calibration N/A
Sensor Life N/A
Range 0.04-0.95 ppm
Unit Features

Glutaraldehyde Range: 0.04 - 0.95 ppm

Sensor Range

0.04-0.95 ppm