R-5005B Hydrazine
This product has been discontinued.
The replacement product is on its way!
K-5005B Hydrazine VACUettes Kit was designed to measure Hydrazine levels from 0-50 ppm.
- SKU
- R-5005B
Description / R-5005B Hydrazine
The K-5005B Hydrazine Kit was designed to accurately measure the levels of hydrazine in water from 0-50 ppm. K-5005B uses the PDMAB Method. CHEMetrics' hydrazine test kits employ the PDMAB, paradimethylaminobenzaldehyde chemistry. PDMAB in acid solution reacts with hydrazine to form a yellow product. Results are expressed as ppb (ug/L) or ppm (mg/L) N2H4.
Hydrazine is a powerful reducing agent that is used in various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out of service for an extended period.
R-5005B Refill Package includes 30 tests and can be purchased separately.
What's Included:
-30 Ampoules
-Comparator
-Dilutor Snapper Cup and lid
-Micro-Test Tube
-Instruction Manual
How to Use:
- Fill the micro-test tube halfway with water sample
- Fill to the dilutor snapper cup to the specific mark with distilled water.
- Ensure the VACUette tip is firmly attached to ampoule tip. Holding the VACUette horizontally, touch the tip to the contents of the micro-test tube.
- Place the VACUette between the vertical tip guides on the inside of the dilutor snapper cup. Snap the ampoule tip.
- Mix ampoule by inverting several times
- Dry the ampoule, and wait 10 minutes for color development.
- Obtain results by placing ampoule between color standards until best color match is found.
Downloads:
P6504:
WARNING! This product can expose you to chemicals including methanol, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
More Information
Manufacturer | CHEMetrics |
---|---|
Gas | Hydrazine |
4-20 mA Output | No |
Voltage Output | None |
Power Requirements | 4 AAA Batteries |
Datalogging | No |
Warranty | 1 Year |
Range | 0-50 ppm |