GX-6000 Sample Draw Gas Detector

The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels.

 

The GX-6000 has 6 operating modes: 

- Normal

- Barhole

- Inert

- Leak Check

- Snap Log

- Benzene Specific

 

As low as $1,545.00

Features:

The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.

 

 

Benefits:

Simultaneous Monitoring: The GX-6000 can simultaneously monitor up to 6 different gases, making it highly versatile for various applications.

Wide Gas Range: It can monitor standard confined space gases such as combustibles, O2, CO, and H2S, as well as accept PID, IR, or super toxic sensors, allowing for a broader range of gas detection.

Internal Sample Pump: Equipped with a strong internal sample pump, it can draw in samples effectively for accurate gas detection.

Safety Features: The instrument includes essential safety features like a man-down alarm and a panic alarm, ensuring the safety of users in hazardous environments.

Built-in Flashlight: It features an LED flashlight, which can be handy in low-light situations.

Large Display: The large auto-rotating LCD display provides clear and easily readable information.

Gas Library: The GX-6000 with a PID sensor comes with a library of over 600 VOC gases to choose from as standard, simplifying gas identification.

Favorites List: Users can create a personalized favorites list of commonly used VOCs for quick access.

Benzene Detection: There's a specific version available for detecting low levels of benzene using a pre-filter tube.

Multiple PID Sensors: Four PID sensor options are available, allowing users to choose the best sensor for their specific needs.

Resistance to Humidity: GX-6000 PID sensors are resistant to humidity, ensuring accurate readings in various environmental conditions.

Rugged Design: The instrument is designed to withstand harsh environments, with a removable impact-resistant rubber boot and a dust and water-resistant enclosure (IP-67 rating).

Visibility: Five bright LED lights on three sides of the instrument make alarms easily visible from different angles.

Audible and Vibration Alarms: It provides both loud audible alarms and vibration alerts, ensuring users are promptly alerted to potential dangers.

Wide Range of Sensors: The GX-6000 supports a variety of sensors, including CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC, making it suitable for diverse industrial and safety applications.

Multiple Operating Modes: It offers six different operating modes such as normal, barhole, inert, leak check, snap log, and benzene specifice , allowing users to tailor its functionality to specific tasks or conditions.

These benefits collectively make the GX-6000 a versatile and reliable gas monitoring instrument suitable for a wide range of applications in challenging environments.

 

Standard Accessories:

- Rubber boot

- Hand strap

- Probe with hydrophobic & dust filter 3' teflon lined hose

- Benzene pre-filter tube and holder (benzene versions)

- Belt clip

- Tapper nozzle

 

Applications:

- Confined space entry

- Hazmat response teams

- Arson investigation

- Remediation site

- Perimeter monitoring

- Leak detection

- Landfill monitoring

- Winery tank entry

 

Datalogging:

10 seconds = 10 hours

5 minutes = 300 hours

10 minutes = 600 hours

 

Video:

 

Quick Start:

 

 

Specifications:

Gas: Detection Range: Alarm Set Points: Continuous Operation:
Carbon Monoxide (CO) 0-500 ppm

 

1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm

 

Alkaline battery: 8 hours

Li-Ion battery: 14 hours
fully recharges in 3 hours

Hydrogen Sulfide (H2S) 0-100 ppm

 

1st 5 ppm
2nd 30 ppm
TWA 1 ppm
STEL 5 ppm

 

Alkaline battery: 8 hours

Li-Ion battery: 14 hours
fully recharges in 3 hours

Combustible Gases 0-100% LEL

 

1st alarm 10% LEL
2nd alarm 50% LEL

 

Alkaline battery: 8 hours

Li-Ion battery: 14 hours
fully recharges in 3 hours

Oxygen (O2) 0-40% Vol

 

High alarm 19.5 Vol.
Low alarm 23.5 Vol.

 

Alkaline battery: 8 hours

Li-Ion battery: 14 hours
fully recharges in 3 hours

 

Alarms:

Gas Alarm Man-down Trouble
Low and high adjustable

1st - self reset

2nd - latching

Low flow sensor connection

Low battery circuit error

Calibration range

 

Common Specifications:

Sample Method

 

Sample draw pump, flow rate 0.45 LPM, 50 foot sample range

 

Display

 

Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases

 

Audible Alarm

 

95 dB at 1 ft.

 

Battery Options

 

Alkaline battery pack only

Alkaline and Li-Ion battery packs with 100-240 VAC charger

Li-Ion battery pack only with 100-240 VAC charger 

Li-Ion battery pack only with 12 VDC charger (Alkaline battery pack not included)

Alkaline and Li-Ion battery packs with 12 VDC charger

Alkaline and Li-Ion battery packs with 100-240 VAC / 12 VDC charger combo charger (Alkaline battery pack not included)

Alkaline and Li-Ion battery pack with 100-240 VAC / 12 VDC combo charger

Li-Ion battery pack only with no charger

 

Languages

 

English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian

 

Operating Temp. & Humidity

 

-4°F to 122°F (-20°C ~ +50℃)

0- 95% RH non condensing

 

Dimensions

 

2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)

 

Case Material

 

Dust and water resistant with IP-67 approval (exclude sample hose and probe)

 

Standard Features

 

2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode

 

Manuals:

- Spec Sheet

- Brochure

- Manual

 

More Information
Manufacturer RKI Intruments
Rental Period Weekly
Description The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels.
Call For Price Yes
Gas Ammonia (NH3), Benzene, Carbon Dioxide (CO2), Carbon Monoxide (CO), Chlorine (Cl2), Hydrocarbon (HC), Hydrogen Cyanide (HCN), Methane (CH4), Phosphine (PH3), Sulfur Dioxide (SO2), VOC
4-20 mA Output No
Field Replaceable Sensor No
Min, Max, Avg No
Voltage Output None
Datalogging No
Rechargeable Yes
Field Replaceable Battery Yes
Warranty 1 Year
Audible Alarm Yes
Features The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart chann
Mobile Mobile
Alarms Gas Alarm, Trouble Alarm, Man Down Alarm and more
Sampling Method Diffusion
Range Gas Dependent
Unit Features

- 5 Operating modes

- Smallest 6 gas sample draw

- 2 Interchangeable smart sensor slots

- Internal sample pump

- Intrinsically safe ATEX / IECEx / cCSAus

Sensor Range

Gas Dependent

- Detect up to 6 Gases

Integrated Relays Yes
Sensor Range

Gas Dependent

Write Your Own Review
You're reviewing:GX-6000 Sample Draw Gas Detector
Your Rating
We found other products you might like!
Loading...