M465L+O2
Low range UV Absorption based Ozone Analyzer for low range ozone detection with superb accuracy. The Model 465L+O2 includes an ozone analyzer for ozone and oxygen safety in the same simple to use monitor.
**This product has been discontinued**
- SKU
- M465l+o2
Description / M465L+O2
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions. An integral micro fuel cell sensor provides accurate, continuous monitoring of O2 and allows measuring of both gases in a single instrument.
The Model 465L + O2 has been designed to deliver excellent performance, high reliability and simple operation. Operating parameters can be easily set up in the field using the operator-friendly menu driven software.
Built-in diagnostics provide warning signals in case operating parameters are out of range. Test values can be viewed while the Model 465L + O2 is operating. These displays, warnings, and self-diagnostics, along with the modular design, allow maximum uptime. In addition, any function that can be set or monitored from the front panel can be remotely set or viewed through the bi-directional RS-232 port.
Features
- O3 and O2 monitoring in a single wall mounted unit
- UV absorption ozone measurement with a 3 ppb LDL
- Maintenance-free, expendable micro fuel O2 cell
- Programmable concentration alarms
- Programmable High and High-High alarm contacts
- Self-check warning alarms
- Temperature and pressure compensation (standard)
- Built-in diagnostics
- Menu driven software
- Fast response times
- Minimal zero drift
- Optional Ethernet
- One-year warranty
Filters
We highly recommend replacing the filter frequently to prevent contamination of the flow path by particulate matter.
Picture of Filter Housing: Product: FILTERHS
Downloads:
M465L Replacement Parts | |
Part Description | Part Number |
UV Lamp Assembly | 065660000 |
UV Detector Assembly | 025710100 |
Reference Scrubber, Low Concentration | 072910001 |
Pump Assembly, 13" Leads | 047020200 |
Power Supply 60W | PS0000042 |
Ozone Sensor Assembly, Low Concentration | 073610100 |
Ozone Sensor Assembly, High Concentration | 073610000 |
O-Ring 2-012 | OR0000039 |
Main Board Assembly | 050720300 |
High Concentration Scrubber | 048990300 |
Reference Scrubber, High Concentration | 050300000 |
Front Panel Board Single Channel | 053130400 |
Flowmeter | FM0000004 |
Filter Inline Disposable | FL0000033 |
Filter Elements, 30 Micron | 036750000 |
Akit Exp. Kit Carulite | 053010000 |
Pre-Filters, Single Stream | 062310000 |
3 Way Valve, Peek/Viton | VA0000054 |
More Information
Manufacturer | Teledyne API |
---|---|
4-20 mA Output | Yes |
Relays | 2 Relays |
Maximum Range | 0-500 ppm |
Minimum Range | 0-1 ppm |
Accuracy | ± 0.5% of full scale |
Min, Max, Avg | No |
Voltage Output | 0-5 V |
Power Requirements | 100 - 240VAC, 50/60 Hz |
Datalogging | No |
Rechargeable | Yes |
Warranty | 1 Year |
Range | From 0-1 ppm to 0-500 ppm |