K-1925 Carbon Dioxide
K-1925 Carbon Dioxide Titrets Kit was designed to obtain Carbon Dioxide levels ranging from 250-2500 ppm
- SKU
- K-1925
Description / K-1925 Carbon Dioxide
Why Choose CHEMetrics Titrets?
CHEMetrics Titrets self-filing reagent ampoules make it easy to perform quick, accurate titrations of water samples. The handheld titrettor that comes with the kit allows the user to easily and reliably control the flow of the solution being measured without the need to count drops or use burets or other equipment. This unique design allows you to perform a titration anywhere and achieve reliable results for a variety of substances.
Safe and Reliable Results:
While traditional methods often require multiple steps and thorough preparation, these test kits allow you to obtain dependable results with a few simple steps. By simplifying the testing method, Tritrets test kits reduce the potential for operator error. Additionally, each of the ampoules contained in the test kits is vacuum sealed which helps eliminate the problem of obtaining inaccurate results from stale or unstable reagents. These reagents are stored right in the tip of each ampoule and sealed in glass, thereby minimizing direct contact with the chemicals.
What's Included:
-30 self-filling Ampoules with valve assemblies -1 25 mL Sample Cup -Activator Solutions -Titrettor -Instruction Manual |
Method:
K-1925 uses the Caustic Titrant with pH indicator Method. Dissolved carbon dioxide (CO2) is naturally present as a result of animal respiration, the decay of organic matter, and the decomposition of certain minerals. It is the major source of acidity in unpolluted water samples. Surface waters typically contain less than 10 ppm (mg/L) dissolved CO2, while ground waters, particularly if deep, may contain several hundred ppm (mg/L).
CHEMetrics' carbon dioxide test kits employ a sodium hydroxide titrant and phenolphthalein indicator. Results are expressed as ppm (mg/L) CO2.
How to Use:
Note: Images used in the following table show a total hardness and colors may differ from the ones shown. Read written instructions to know what color changes to expect from your substance.
1. Fill the sample cup to the 20 mL mark with the sample to be tested. | 2. Add 2 drops of the Activator Solution. Stir to mix the contents of the cup. |
3. Snap the tip of the ampoule at the black snap ring. | 4. Lift the control bar and insert the Titret assembly into the Titrettor. |
5. Hold the Titrettor with the sample pipe in the sample. Press the control bar firmly, but briefly, to pull in a small amount of sample. The contents will turn pink. | 6. Press the control bar again to draw another small amount of sample into the ampoule. |
7. Rock the entire assembly to mix the contents of the ampoule. Watch for a color change from pink to colorless. Repeat steps 6 and 7 until a permanent color change occurs. | 8. When the color of the liquid in the ampoule changes to colorless, remove the ampoule from the Titrettor. Hold the ampoule tip pointed upward and read the scale opposite the liquid level. Results are expressed in ppm carbon dioxide. |
P6508
WARNING! This product can expose you to chemicals including ethylene glycol, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
More CHEMetrics Kits for Carbon Dioxide:
Titrets | ||||
---|---|---|---|---|
Product Number | Method | MDS | Range | Price |
K1910 | Caustic Titrant with pH Indicator | 10 ppm | 10-100 ppm | $33.00 |
K1920 | Caustic Titrant with pH Indicator | 100 ppm | 100-1000 ppm | $33.00 |
K1925 | Caustic Titrant with pH Indicator | 250 ppm | 250-2500 ppm | $33.00 |
Downloads and Links:
More Information
Manufacturer | CHEMetrics |
---|---|
Gas | Carbon Dioxide (CO2) |
4-20 mA Output | No |
Voltage Output | None |
Power Requirements | 4 AAA Batteries |
Datalogging | No |
Warranty | 1 Year |
Range | 250-2500 ppm |