K-8012C Phenols

This product has been discontinued.

The replacement product is on its way!

 

 

K-8012C Phenols Kit was designed to obtain Phenols levels from 0-1000 ppm and 0-13,000 ppm

Replacement ampoules for the K-8012C Test Kit can be found here.

Phenols Information

Call For Price

2-5 business days

Why Choose CHEMetrics Vacuettes kits?

VACUettes ampoules are designed for highly concentrated samples. They employ a patented auto-dilution feature that eliminates the need for a time-consuming and error-prone preliminary dilution. As a result, the entire test takes only 2 to 3 minutes, with a rate of accuracy comparable to a volumetric procedure. The basic design of these 7 mm ampoules is the same as CHEMets ampoules, however, a capillary tip is attached to the tip of each ampoule.

Safe and Reliable Results:

While traditional methods often require multiple steps and thorough preparation, these test kits allow you to obtain dependable results with a few simple steps. By simplifying the testing method, Vacuettes test kits reduce the potential for operator error. Additionally, each of the ampoules contained in the test kits is vacuum sealed which helps eliminate the problem of obtaining inaccurate results from stale or unstable reagents. These reagents are stored right in the tip of each ampoule and sealed in glass, thereby minimizing direct contact with the chemicals.

What's Included:

     -30 self-filling Ampoules

     -Comparators

     -Diluter snapper cup

     -Micro test tube

     -Instruction Manual

 

Method:

The K-8012C Phenols Kit was designed to accurately measure the levels of Phenols in water from 0-1000 ppm and 0-13,000 ppm. K-8012C uses the 4-Aminoantipyrine Method. CHEMetrics' phenols kits employ the well-established 4-aminoantipyrine (4-AAP) method. Phenolic compounds react with 4-AAP in alkaline solution in the presence of ferricyanide to produce a red reaction product. Phenol, meta-, and ortho-substituted phenols, and some para-substituted phenols, under proper pH conditions, are detected with this method. The method is applicable to the monitoring of phenolic compounds in wastewater. Results are expressed as ppm (mg/L) phenol. 

Phenol (hydroxybenzene) is the simplest of a group of similar organic chemicals, which includes cresols, xylenols, and catechols. Phenol itself is a common ingredient of disinfectants. In drinking water, low-level phenolic concentrations impart a foul taste and odor, especially upon chlorination. High phenol concentrations can indicate contamination from industrial effluents or waste discharge.

1. Fill the diluter snapper cup to the -ml- mark with distilled water. Dissolve the crystals on the tip of the
ampoule by stirring for 10 seconds with the ampoule tip.
2. Fill the micro-test tube approximately halfway with the sample to be tested.
3. Holding the VACUette almost horizontally,
touch the tip to the contents of the micro-test
tube.
4. Place the VACUette between the vertical tip
guides on the inside of the dilutor snapper
cup and snap the ampoule tip. 
 
5.To mix the ampoule, invert it several times,
allowing the bubble to travel from end to end.
6. Dry the ampoule. Obtain the test result 1 minute after snapping the tip.
7. Place the ampoule into the center of the round comparator and hold it toward a source of light, viewing from the bottom. Rotate the comparator until the color below the ampoule shows the closest match. 8. For higher concentrations, use flat comparator. Place the ampoule between the color standards, moving it along the comparator until you can determine the closest match.

For more detailed instructions, see the link at the bottom of the page.

More CHEMetrics Kits for Phenols:

Vacu-Vials
Product Number Method   Range Price
K8003 4-Aminoantipyrine   0-8.00 ppm $30.00
K8023 4-Aminoantipyrine   0-20.0 ppm  
Chemets Kits
Product Number Method MDL Range Price
K8012 4-Aminoantipyrine 0.05 ppm 0-1 & 1-12ppm $68.00
Vacuettes
Product Number Method MDL Range Price
K8012D 4-Aminoantipyrine 5 ppb 0-30 & 0-350 ppm $71.00
K8012A 4-Aminoantipyrine 10 ppm 0-60 & 0-700 ppm $71.00
K8012B 4-Aminoantipyrine 20 ppm 0-120 & 0-1400 ppm $71.00
K8012C 4-Aminoantipyrine 100 ppm 0-1000 & 0-13,000 ppm $72.00

 

Downloads:

K-8012A-D Instructions

Safety Data Sheets

Phenols Tech Sheet

Phenols Information

 

More Information
Manufacturer CHEMetrics
Call For Price No
Gas Phenols
4-20 mA Output No
Voltage Output None
Power Requirements 4 AAA Batteries
Datalogging No
Warranty 1 Year
Range 0-1000 ppm and 0-13,000 ppm
Write Your Own Review
You're reviewing:K-8012C Phenols
Your Rating
We found other products you might like!
Loading...