K-8020D Phenols
K-8020D Phenols
K-8020D Phenols Kit is used to determine Phenol levels from 0-300 ppm.
Replacement ampoules for the K-8020D Test Kit can be found here.
- SKU
- K-8020D
Description / K-8020D Phenols
Why Choose HR CHEMets kits?
HR CHEMets® is the new way to test at high ranges and replaces the now discontinued VACUettes product line. This product's measurement ranges overlaps with the discontinued K-8012D test kit.
Included:
|
- 30 self-filling Ampoules - Flat Comparator - Diluter snapper cup - Micro test tube - Iron activator -Instruction Manual |
Method:
The K-8020D Phenols HR CHEMets® Test Kit (0-300 ppm) comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): HR CHEMets® Refill, Flat Comparator, 25 mL sample cup, 1.0 mL syringe, and instructions.
| 1. Using the syringe provided, obtain 2.5 mL of the sample to be tested, and then dispense it into the empty sample cup. | 2. Dilute the contents of the sample cup to the 25 mL mark with distilled water (fig 1). |
![]() |
![]() |
| 3. Place the CHEMet ampoule, tip first, into the sample cup. Snap the tip. The ampoule will fill leaving a bubble for mixing (fig 2). | 4. To mix the ampoule, invert it several times, allowing the bubble to travel from end to end. Dry the ampoule. Obtain a test result 4 minutes after snapping the tip. Obtain a test result by placing the ampoule between the color standards until the best color match is found (fig. 3). |
![]() |
For more detailed instructions, see the link at the bottom of the page.
More CHEMetrics Kits for Phenols:
| Vacu-Vials | ||||
|---|---|---|---|---|
| Product Number | Method | Range | Price | |
| K8003 | 4-Aminoantipyrine | 0-8.00 ppm | $30.00 | |
| K8023 | 4-Aminoantipyrine | 0-20.0 ppm | ||
| Chemets Kits | ||||
| Product Number | Method | MDL | Range | Price |
| K8012 | 4-Aminoantipyrine | 0.05 ppm | 0-1 & 1-12ppm | $68.00 |
| Vacuettes | ||||
| Product Number | Method | MDL | Range | Price |
| K8020D | 4-Aminoantipyrine | 25 ppb | 0-300 ppm | $71.00 |
| K8012A | 4-Aminoantipyrine | 10 ppm | 0-60 & 0-700 ppm | $71.00 |
| K8012B | 4-Aminoantipyrine | 20 ppm | 0-120 & 0-1400 ppm | $71.00 |
| K8012C | 4-Aminoantipyrine | 100 ppm | 0-1000 & 0-13,000 ppm | $72.00 |
Downloads:
More Information
| Manufacturer | CHEMetrics |
|---|---|
| Gas | Phenols |
| 4-20 mA Output | No |
| Voltage Output | None |
| Datalogging | No |
| Warranty | 1 Year |
| Method | 4-Aminoantipyrine |
| MDL | 25 ppm |
| Range | 0-300 ppm |