R-2509 Chlorine

Dissolved Chlorine Testing Visual Kit

Measure chlorine 0-100ppm & 0-500ppm or 0-400ppm & 0-2000ppm

*Use with the K-2504B & K-2504C*

Chlorine Information

$31.00

The R-2509 CHEMets Visual Ampoules Kit contains 30 additional ampoules and pipette tips to perform testing of the chlorine level.  R-2509 Ampoules are used with the K-2504B or K-2504C which is a visual indicator of the ppm of chlorine. The R-2509 comes in a nice box that can easily be stored in case of the K-2504B or C.

The cost per test is $1.04.

The K-2504B CHEMets Visual Kit is visual indicator kit for measuring chlorine in water levels from 0-100 and 0-500ppm.  The K-2504A CHEMets Visual Kit is visual indicator kit for measuring chlorine in water levels from 0-400 and 0-2000ppm. This device uses the DPD Method for testing. Free chlorine oxidizes DPD (N,N-diethyl-p-phenylenediamine) to form a pink colored species in direct proportion to the chlorine concentration. Total chlorine, the sum of free and combined chlorine, is determined by adding an excess of potassium iodide to the sample. Chloramines (combined chlorine) oxidize the iodide to iodine. The iodine then oxidizes DPD to the pink colored species. Other halogens, ozone and halogenating agents will produce high test results. Chlorine at concentrations significantly above the test range may prevent proper color development, causing low test results.

 

What's included:

  • R-2509 Chlorine Visual Ampoules (30 test)
  • Pipette Tips
  • Instruction manual

 

How to use the K-2504B/C & R-2509:

Instructions for Ozone water testing using the K-7404

 

 

SAFETY INFORMATION 
Please review the SDS before performing this test procedure. Wear safety glasses and protective gloves.

 

FREE CHLORINE PROCEDURE:

 

  1. Place a yellow pipette tip firmly onto the end of the MiniPet®. Note: A fresh pipette tip should be used for each test.
  2. Depress the plunger on the minipet. Immerse the tip in the sample to be tested and release the plunger.  A portion of the sample will be drawn into the tip.  Note: Do not touch the side or bottom of the sample container with the tip during sampling.
  3. Hold the minipet over the sample cup, and depress the plunger to dispense sample.
  4. Dilute the contents of the sample cup to the 20 mL sample cup with distilled water.Fill the sample cup to 25ml
  5. Snap the end/tip of the ampoule in the water on the bottom/side of the 20 mL sample cup.
  6. Mix the contents of the ampule by tipping back and forth a few times.Tip the vacu-vial back and forth to mix
  7. Dry the ampoule and wait 1 minute for color development.Dry vacu-vial and then insert into the I-2019
  8. Obtain the test result by matching to the corresponding color comparator.
  9. For the low range comparator: Place the ampoule, flat end first, into the comparator.  Hold the comparator up towards a light source and view from the bottom. Rotate the comparator until the best color match is found.

 

 

 

TOTAL CHLORINE PROCEDURE:

 

  1. Place a yellow pipette tip firmly onto the end of the MiniPet®. Note: A fresh pipette tip should be used for each test.
  2. Depress the plunger on the minipet. Immerse the tip in the sample to be tested and release the plunger.  A portion of the sample will be drawn into the tip.  Note: Do not touch the side or bottom of the sample container with the tip during sampling.
  3. Hold the minipet over the sample cup, and depress the plunger to dispense sample.
  4. Dilute the contents of the sample cup to the 20 mL sample cup with distilled water.
  5. Add 4 drops of A-2500 Activator Solution. Stir briefly.
  6. Snap the end/tip of the ampoule in the water on the bottom/side of the 20 mL sample cup.Snap the tip of the ampoule on the bottom and side of the sample cup
  7. Mix the contents of the ampule by tipping back and forth a few times.Tip the vacu-vial back and forth to mix
  8. Dry the ampoule and wait 1 minute for color development.Dry vacu-vial and then insert into the I-2019
  9. Obtain the test result by matching to the corresponding color comparator.
  10. For the low range comparator: Place the ampoule, flat end first, into the comparator.  Hold the comparator up towards a light source and view from the bottom. Rotate the comparator until the best color match is found.

 

 

Downloads:

K-2504B/K-2504C/R2509 Instructions

Chlorine Information

 

More Information
Manufacturer CHEMetrics
Call For Price No
Gas Chlorine (Cl2)
4-20 mA Output No
Voltage Output None
Power Requirements None
Datalogging No
Warranty 1 Year