Aeroqual Ammonia (NH3) Sensor Head 0-100 ppm (ENG)

Aeroqual Ammonia (NH3) Sensor Head 0-100 ppm (ENG)

The Aeroqual 0-100 ppm Ammonia Sensor Head is designed to provide accurate, consistent readings of the ammonia in your ambient airspace. It can serve as a replacement to your existing Ammonia head, or can add ammonia-sensing capability to your current Aeroqual monitor!

Ammonia Information

SKU
AQ ENG

Customizable Options:

$746.00

Description / Aeroqual Ammonia (NH3) Sensor Head 0-100 ppm (ENG)

Ammonia (NH3) sensor head. Gas Sensitive Electrochemical (GSE) head will measure Ammonia from 0-100 ppm with a 0.1 ppm resolution providing a <±10% accuracy.

 

Detailed info sheet on Aeroqual Ammonia Sensor

Full list of technical information and specifications for all Aeroqual sensors

Ammonia Information

 

This head uses an active sensor technology with an internal fan to pull air accross the GSE sensor at a specific flow rate for accurate gas detection.  The fan will pull a fresh gas stream across the GSE sensor every 120 seconds for accurate Ammonia detection.

This sensor head will be a direct fit onto any Series-300, Series-500 or Ranger Aeroqual ozone monitor.  This head can be purchased as an addition to your existing monitor, or with a new base unit.  To purchase with a base unit see our Aeroqual ozone monitor page.  If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor.  

 

 

Compare the Series 300 and 500, Aeroqual Ranger monitors:

Compare the Aeroqual handheld devices

Series-300

Aeroqual Series-300

Series-500

Aeroqual S-500

Aeroqual Ranger

 

Interchangeable sensor head Yes Yes Yes
Digital LCD Display Yes Yes Yes
Min, Max, Average readings on screen Yes Yes Yes
Field Replaceable Battery Yes Yes Yes
Remote Sensor Capability Yes Yes Yes
Temp and HR Sensor optional Yes Yes Yes
External Control Outputs Yes Yes Yes
Audible Alarm Yes Yes Yes
High and Low Alarms Yes Yes Yes
0-5 VDC Analog output Yes Yes Yes
Zero Calibration capability Yes Yes Yes
Span Calibration capability Yes Yes Yes
Internal Data Logging Capability No Yes Yes

PC connection cables and capability

No Yes

Yes

Built in wi-fi connection

No No

Yes

Hot-Swap Service 

Yes Yes

Yes

 

 

 

Detailed Sensor Specifications for Aeroqual ambient sensors

Click on image to expand

 

Calibration:

This sensor is a Gas Sensitive Electrochemical (GSE) sensor. The Aeroqual ENG sensor has a detection range of 0-100 ppm, so the calibration gas you use must fall within this range. Refer to the table below for our recommended calibration gas options.

Product Range Price
Ammonia Calibration - Kit 58L
Ammonia Calibration - Kit 58L
50ppm
$1,275.00
Ammonia Calibration Kit
Ammonia Calibration Kit
25 ppm, 50 ppm, 100 ppm, 250 ppm, 300 ppm
$614.00
GENie QC-1 Ammonia Calibration System
GENie QC-1 Ammonia Calibration System
Multiple Ranges Call For Price
Ammonia Calibration - Kit 58L

Ammonia Calibration - Kit 58L

$1,275.00

Range

50ppm
View Details
Ammonia Calibration Kit

Ammonia Calibration Kit

$614.00

Range

25 ppm, 50 ppm, 100 ppm, 250 ppm, 300 ppm
View Details
GENie QC-1 Ammonia Calibration System

GENie QC-1 Ammonia Calibration System

Call For Price

Range

Multiple Ranges
View Details

 

 

Sensor Type:

There are two types of Aeroqual sensors, type 1 and type 2. 
The type 1 is used with the S-200, S-300, S-500, Ranger and S-900 monitors.
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930

Aeroqual type-1 and type-2 sensors types

 

 

 

All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures. 

**Calibration Service Request Form **

 

More Information

Manufacturer Aeroqual
Gas Ammonia (NH3)
Sensor Type GSE (Gas Sensitive Electrochemical)
Range 0-100 ppm
Maximum Exposure 200 ppm
Monitor sensor fits S-200 / S-300 / S-500, Series-900, Series-930, Ranger
Minimum Detection Limit 0.2 ppm
Accuracy < +/- 10 ppm
Resolution 0.1 ppm
Response Time <60 s
Sampling Method Fan
Operational Temperature Range 0 to 40°C
Operational RH Range 10 to 90%
Warranty 6 Month