Analytical Technologies Incorporated (ATI)
This information applies to the sensor module used in the C16 , F12 , and D12 Monitors.
ATI Smart Sensors come pre-calibrated and have all calibration information loaded on the sensor. The sensor can be swapped between monitors without any special requirements for proper calibration.
Sensors are fairly low cost and are replaced annually to remain in calibration. Periodic bump tests can be performed to ensure the sensor is still ope...
-
Chlorine:
Other Names
Bertholite
Chemical Formula
Cl 2
CAS Number
7782-50-5
Industry Uses
Water Purification, Household Cleaners, Pool and Spa Treatments, Pesticides
Health Risks
Eye, throat, and airway irritation; pulmonary edema, death; skin burns; coughing, vomiting
Vapor Pressure
6.8 atm ...
-
Chloride:
Other Names
Chloride ion
Chemical Formula
Cl -
CAS Number
16887 – 00 – 6
Industry Uses
Salts; Chemical Intermediate; Water Treatment
Health Risks
Skin reaction
What is Chloride:
Chloride is a chlorine anion that forms the negatively charged part of many salts. It is the mo...
-
Hypochlorite:
Other Names
Hypochlorite Ion
Chemical Formula
ClO -
CAS Number
14380 – 61 – 1
Industry Uses
Bleach; Disinfectant; Water Treatment
Health Risks
Irritant; Respiratory Symptoms
Hypochlorite MSDS
What is Hypochlorite:
Hypochlorite is an ion composed of chlorine and o...
-
Chlorine Dioxide:
Other Names
Chloroperoxyl, chlorine peroxide, chlorine oxide
Chemical Formula
ClO 2
CAS Number
10049-04-4
Industry Uses
Water Purification, Paper Manufacturing
Health Risks
Eye, throat, and airway irritation; pulmonary edema, death; skin burns; coughing, vomiting
Vapor Pressure
...
-
Hydrogen Chloride:
Other Names
Hydrochloric Acid; Muriatic Acid
Chemical Formula
HCl
CAS Number
7647-01-0
Industry Uses
Chemistry Laboratories; Fertilizers; Cleaners; Dyes
Health Risks
Irritation of eyes, skin, and respiratory system; Burns and Frostbite
Vapor Pressure
40.5 atm
...
-
The Portasens is known as a great ambient air portable gas leak detector that features: - electrochemical smart-cell sensor (which can be calibrated independently of the unit) - available to measure over 30 types of gases - a rugged internal sample pump - excellent accuracy and repeatability - easy to read back-lit LED display - flexible wand for pinpointing leak points - datalogging capabilities - integrated audible alarms
Because of the many attractive features a...
-
Aeroqual
Aeroqual SM-70 Controller
Aeroqual Series-100 Controller
Aeroqual Series-200 Monitor Quick Start Guide
Aeroqual Series-200 Monitor User Manual
Aeroqual Series-300 Monitor Quick Start guide
Aeroqual Series-300 Monitor User Manual
Aeroqual Series-500 Monitor Quick Start guide
Aeroqual Series-500 Monitor User Manual
Aeroqual Series-320 Monitor User Manual
Aeroqual Series-520 Monitor User Manual
Aeroqual Series-900 Controller/Transmitter
Aer...
-
Perchloroethylene(PERC):
Perchloroethylene Safety and Detection information
Overview:
Other Names:
PERC, PCE, perchlorethylene, tetrachloroethylene, tetrachlorethylene
Chemical Formula:
C 2 Cl 4
CAS Number:
127-18-4
Industry Uses:
Dry Cleaning, Metal Degreasing, Chemical Manufacturing
Health Risks:
Carcinogen, Irritant, Adverse nervous system reactions
...
-
Volatile Organic Compound (VOC):
What is VOC:
Volatile Organic Compounds, more commonly known as VOC's consist of a wide variety of organic compounds that are vapor at room temperature. Many different gasses may make up VOC's, and some of those gasses may also be associated with other families of gasses. A complete list of VOC's can be found at the bottom of this page.
Health Risks of VOC's:
VOC's can cause respiratory, allergic, or immune effects...
-
General Calibration Information
All Gas Sensors will require periodic calibration to ensure your gas measurements are accurate and correct. Different gasses, and sensor manufactrers will have differeing requirements and methods for calibration. This page will serve to provide general calibration information and links to specific calibration procedures from the sensor manufacturers we represent.
Should you have any questions about sensor calibration, or would like us to help you with your ...
-
Gas Information
Information on gasses and what monitor may be right for you can be found at the links below.
Ammonia
Carbon Monoxide
Hydrogen Sulfide
Nitrogen Dioxide
Ozone
Perchloroethylene
Volatile Organic Compound (VOC)
Manuals
Find operation manuals here
Specif...
-
Cyanide:
Other Names
Cyanide Ion; Isocyanide; Nitrile Anion
Chemical Formula
CN -
CAS Number
57 – 12 – 5
Industry Uses
Mining; Pest Control; Metal Cleaning; Steel Manufacture
Health Risks
Irritation; Histotoxic hypoxia;
Cyanide MSDS
What is Cyanide:
Cyanide is used in many chemic...
-
Hardness:
What is Water Hardness:
Water Hardness is a measure of mineral content in water. Hard water is formed when water flows through deposits of limestone and chalk which are made up largely of calcium and magnesium. Hardness is determined by the concentration of multivalent cations, which are positively charged metal complexes with a charge greater than +1. Common cations in hard water are Calcium (Ca+2) and Magnesium (Mg+2). There are two types of hardness, temporary an...
-
Phenol:
Other Names
Carbolic Acid; Hydroxybenzene; Phenic Acid
Chemical Formula
C 6 H 6 O; C 6 H 5 OH
CAS Number
108 – 95 – 2
Industry Uses
Antiseptic; Disinfectant; Pharmaceutical and Chemical Production
Health Risks
Irritant; Dermal Burns; Organ Damage; Death
Phenol MSDS
What is Phen...
-
Sulfite:
Other Names
Sulphite; Sulfite ion
Chemical Formula
SO 3 2-
CAS Number
14265 – 45 – 3
Industry Uses
Food Additive; Antioxidant; Antimicrobial
Health Risks
Allergic Reaction
Sulfite MSDS
What is Sulfite:
Sulfite is not usually present in surface waters. If sulfite is di...
-
Thiosulfate:
Other Names
Thiosulphate; Thiosulfate Ion
Chemical Formula
S 2 O 3 2-
CAS Number
14383 – 50 – 7
Industry Uses
Bleaching; Chemical Laboratories
Health Risks
Irritation
Thiosulfate MSDS
What is Thiosulfate:
Thiosulfate is an excellent reducing agent. It is used prim...
-
Hydrogen Fluoride:
Other Names
Hydrofluoric Acid; Fluorhydric Acid; Fluorane
Chemical Formula
HF
CAS Number
7664-39-3
Industry Uses
Chemistry Laboratories; Aluminum Production; Glass Etching
Health Risks
Irritation of eyes, skin, and respiratory system; Pulmonary Edema; Fluorosis
Vapor Pressure
...
-
Peracetic Acid:
Other Names
Peroxyacetic Acid; Ethaneperoxic Acid
Chemical Formula
C 2 H 4 O 3 ; CH 3 COOOH
CAS Number
79 – 21 – 0
Industry Uses
Bleaching and Cleaning; Antimicrobial; Chemical Laboratories
Health Risks
Irritation; Burning; Respiratory Distress; Death
Vapor Pressure
...
-
Phosgene:
Other Names
Carbonyl dichloride; Carbonic dichloride; Chloroformyl chloride
Chemical Formula
COCl 2 ; CCl 2 O
CAS Number
75 – 44 – 5
Industry Uses
Chemical Warfare; Chemical Laboratories; Pesticides
Health Risks
Irritation; Vomiting; Foamy Sputum; Dyspnea; Respiratory Damage; Death
...
-
Hydrogen Cyanide:
Other Names
Hydrocyanic acid; Formonitrile; Prussic Acid
Chemical Formula
HCN
CAS Number
74-90-8
Industry Uses
Chemistry Laboratories; Fumigation
Health Risks
Irritation of eyes, skin, and respiratory system; Organ Failure; Death
Vapor Pressure
630 mmHg
...
-
We provide Gas Sensors for every workplace, or safety need.
Gas sensors for leak detection
Work place safety alarm
Personal safety sensor
Hazardous location sensor
UV Analyzers
OEM Solutions
Contact us to help you choose the right Sensor for your application:
605-368-1404
sales@gas-sensing.com
Portable Gas Sensors
Fixed Mount Gas Sensors
Re...
-
Gas-Sensing is a partner company to Oxidation Technologies, LLC. Oxidation Technologies provides services and products exclusively to the ozone industry. For all ozone related inquiries please refer to Oxidation Technologies.
What is Ozone?
The oxygen atom is unstable in the atomic form. Oxygen is stable in the diatomic form as O2. The air we breath today is made up of about 21% oxygen, this makes oxygen one of the most common molecules found in nature today.
Ozone is a triato...