K-5513 Hydrogen Peroxide
*item has been discontinued*
K-5513 Peroxide Vacu-vials Kit was designed to obtain Peroxide levels from 0-3.0 ppm
This kit requires the use of a CHEMetrics Direct-Readout Photometer, the I-2016 Hydrogen Peroxide SAM kit, or a spectrophotometer capable of accepting a 13 mm diameter round cell. Instrument sold separately.
- SKU
- K-5513
Description / K-5513 Hydrogen Peroxide
Why Choose Vacu-vials?
CHEMetrics Vacu-vials self-filling ampoules are a great way to test for dissolved substances in liquid. Unlike our visual test kits, the Vacu-vials test kit allows you to obtain an instrumental result using the CHEMetrics Direct-Redout Photometers or any spectrophotometer capable of accepting a 13m diameter round cell. When using equipment from another manufacturer, set the spectrophotometer to absorbance mode, select the wavelength specified by the Vacu-vials kit instructions, and follow the test procedure. The K-1503 Ammonia Kit is designed to accurately measure the levels of Ammonia in water from 0-7.00 ppm.
Safe and Reliable Results
While traditional methods often require multiple steps and thorough preparation, these test kits allow you to obtain dependable results with a few simple steps. By simplifying the testing method, Vacuvials test kits reduce the potential for operator error. Additionally, each of the ampoules contained in the test kits is vacuum sealed which helps eliminate the problem of obtaining inaccurate results from stale or unstable reagents. These reagents are stored right in the tip of each ampoule and sealed in glass, thereby minimizing direct contact with the chemicals.
What's included:
|
Method
The K-5513 Hydrogen Peroxide Kit was designed to accurately measure the levels of Hydrogen Peroxide in water from 0-3.0 ppm. K-5513 uses the DPD Method. In the DPD Method, hydrogen peroxide reacts with DPD (N, N-diethyl-p-phenylenediamine) in the presence of potassium iodide and ammonium molybdate to form a pink color. Various oxidizing agents such as halogens, ozone, and peracetic acid will produce high test results. Results are expressed as ppm (mg/L) H2O2.
Â
How to use:
1. Fill the sample cup to the 25 mL mark with the sample to be tested. | 2. Add 5 drops of Activator Solution A-5502, then 2 drops of Activator Solution A-5500. Stir to mix the contents of the cup and wait 6 minutes. |
3. Place the Vacu-vial ampoule tip-first into the sample cup. Snap the tip and the ampoule will automatically fill. | 4. To mix the ampoule, tilt it from side to side, allowing the bubble to travel from end to end. |
5. Dry the ampoule and wait 1 minute for color development. | 6. Insert the Vacu-vial ampoule into the photometer, flat end first, and obtain a reading in ppm. |
Â
Â
More CHEMetrics Kits for Hydrogen Peroxide
Vacu-Vials | ||||
---|---|---|---|---|
Product Number | Method | Â | Range | Price |
K5543 | Ferric Thiocyanate | Â | 0-6.00Â ppm | $30.00 |
I2016 | Ferric Thiocyanate | Â | 0-6.00Â ppm | $415.00 |
Chemets Kits | ||||
Product Number | Method | MDS | Range | Price |
K5502 | Direct Nesslerization | 0.05ppm | 0-0.5Â ppm | $52.00 |
K5510 | Hydroxybenzyl Alcohol (HBA) | 0.125ppm | 0-0.8 & 1-10Â ppm | $66.00 |
Vacuettes | ||||
Product Number | Method | MDS | Range | Price |
K5510D | Direct Nesslerization | 10ppm | 0-25 & 30-300 ppm | $71.00 |
K5510A | Direct Nesslerization | 20ppm | 0-50 & 60-600 ppm | $71.00 |
K5510B | Direct Nesslerization | 100ppm | 0-100 & 120-1200 ppm | $72.00 |
K5510C | Direct Nesslerization | 5ppm | 0-1000 & 1200-12,000 ppm | $71.00 |
Titrets | ||||
Product Number | Method | MDS | Range | Price |
K-5530 | Ceric Sulfate Titrant with Ferroin Indicator | 0.10% | 0.1%-1.0% (up to 20% with dilution) | $33.00 |
Â
Downloads:
Â
More Information
Manufacturer | CHEMetrics |
---|---|
Gas | Hydrogen Peroxide (H2O2) |
4-20 mA Output | No |
Voltage Output | None |
Power Requirements | 4 AAA Batteries |
Datalogging | No |
Warranty | 1 Year |
Range | 0-3.0 ppm |