K-7020C Nitrite

K-7020C Nitrite Kit is used to determine Nitrite levels from 0-2000 ppm.
Replacement ampoules for the K-7020C Test Kit can be found here.
- SKU
- K-7020C
Description / K-7020C Nitrite
Why Choose HR CHEMets kits?
HR CHEMets® is the new way to test at high ranges and replaces the now discontinued VACUettes product line. This product's measurement ranges overlaps with the discontinued K-7004C test kit.
The K-7020C Nitrite HR CHEMets® Test Kit (0-2000 ppm) comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): HR CHEMets® Refill, Flat Comparator, 25 mL sample cup, pipettor tips, 25 uL fixed volume pipet, and instructions.
What's Included:
- 30 CHEMets Ampoules - Color Comparator - 1 25 mL Sample Cup - Stabilizer Solution - Catalyzer Solution - Activator Solution - 3 mL syringe - MiniPet - Pipettos Tips Pack - Instruction Manual |
Method:
The Nitrite CHEMets®1 test kit employs the azo dye formation method.2,3 In an acidic solution, nitrite diazotizes with a primary aromatic amine and then couples with another organic molecule to produce a highly colored azo dye. The resulting pink-orange color is proportional to the nitrite concentration in the sample.
1. Place a pipette tip firmly onto the end of the MiniPet®4 (fig. 1). Note: Use a fresh pipette tip for each test. | 2. Depress the plunger on the minipet. Immerse the tip in the sample to be tested and release the plunger. A portion of the sample will be drawn into the tip (fig. 2). |
![]() |
![]() |
3. Hold the minipet over the empty sample cup, and depress the plunger to dispense sample (fig. 3). | 4. Dilute the contents of the sample cup to the 25 ml mark with distilled water (fig. 4). |
![]() |
![]() |
5. Add solutions to the sample cup in the following order (fig. 5). 5 drops S-1404 Stabilizer 5 drops S-1405 Catalyzer (green) 5 drops S-1406 Activator (blue) |
6. Immediately place the CHEMet ampoule, tip first, into the sample cup. Snap the tip. The ampoule will fill leaving a bubble for mixing (fig. 6). To mix the ampoule, invert it several times, allowing the bubble to travel from end to end. Dry the ampoule. Obtain a test result 5 minutes after snapping the tip. |
![]() |
![]() |
7. Obtain a test result by placing the ampoule between the color standards until the best color match is found (fig. 7). NOTE: Use the concentration scale on the comparator label that corresponds to the range of the test procedure being used. |
0 - 10,000 ppm Test Procedure
|
![]() |
For more detailed instructions, see the link at the bottom of the page.
P6508:
WARNING! This product can expose you to chemicals including ethylene glycol, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
More CHEMetrics Kits for Nitrite:
Titrets | ||||
---|---|---|---|---|
Product Number | Method | MDS | Range | Price |
K7025 | Ceric Sulfate Titrant with Ferroin Indicator | 250 ppm | 250-2500 ppm as NaNO2 | $33.00 |
K7050 | Ceric Sulfate Titrant with Ferroin Indicator | 500 ppm | 500-5000 ppm as NaNO2 | $33.00 |
Vacu-Vials | ||||
Product Number | Method | Range | Price | |
K7003 | Azo Dye Formation | 0-1.00 ppm as N | $32.00 | |
Chemets Kits | ||||
Product Number | Method | MDL | Range | Price |
K7004 | Azo Dye Formation | 0.2 ppm | 0-2.5 ppm as N | $68.00 |
Vacuettes | ||||
Product Number | Method | MDL | Range | Price |
K7004D | Azo Dye Formation | 4 ppm | 0-80 ppm as N | $61.00 |
K7004A | Azo Dye Formation | 10 ppm | 0-170 ppm as N | $61.00 |
K7020B | Azo Dye Formation | 20 ppm | 0-300 ppm as N | $61.00 |
K7020C | Azo Dye Formation | 200 ppm | 0-3000 ppm as N | $62.00 |
Downloads:
More Information
Manufacturer | CHEMetrics |
---|---|
Gas | Nitrite |
4-20 mA Output | No |
Voltage Output | None |
Datalogging | No |
Warranty | 1 Year |
Method | Azo Dye Formation |
MDL | 160 ppm |
Range | 0-2000 ppm |