F12-D Remote Sensor jct box

F12-D Remote Sensor jct box

The Series F12D Gas Transmitter is designed for detection of a variety of toxic gases in hazardous area applications.  In addition, it is also well suited for all general purpose applications where toxic gas measurement is required. The F12D has a remote sensor with a junction box & is powered by 115V power.

Part Number: ATI F12D-3-2-1-1

SKU
ATI F12D-3-2-1-1

Options

Customizable Options:

As low as: $1,831.00

Description / F12-D Remote Sensor jct box

*This is a pre-configured F12-D Gas Monitor that we keep in stock - this configuration comes with the following specifications:

     -115 VAC

     -50/60 Hz with Alarms

     -Remote Sensor Holder with Junction Box

     -No Auto Test

     -No Digital Output

 

Click Here to view the fully customizable F12-D Gas Monitor

 

The Series F12 Gas Transmitter is well suited for all general purpose applications where toxic gas measurement is required.

F12 Transmitters use ATI's standard smart sensors for maximum flexibility.  Sensors are easily exchanged and contain all calibration constants in sensor memory, eliminating the need for field calibration of transmitters.  Sensors may be calibrated separately on the bench and then simply plugged into the transmitter.  Calibration data is read into the transmitter automatically and no other adjustments are normally required.

For Intrinsically Safe (IS) applications, the F12 transmitter is available as an F-12is version.  One version provides for easy interface to RS-484 networks using a standard MODBUS communication protocol.  A second version provides a complete AC powered instrument with 3 alarm relays (SPST) available for external alarming

 

F12 Options (how to order):

Note: This F12-D is pre-configured, to see the fully customizable F12-D where the following options are applicable, Please Click Here. The F-12 is highly customizable to fit your every need.  Please review the options closely to ensure you choose the right configuration for your application.  Please call if you have any questions or need help configuring the right sensor for your application. The below options are other ways to configure the F12, please use the link above to go to our fully configurable F12-D.

Sensor Module:

Choose the gas and range of detection required for your application

Transmitter Type:

  • 12-30VDC model for RS-485 communication is standard
  • 115-230vac, 50/60Hz power with relay board
  • 12-30VDC power with relay board 

Choose the voltage that is right for you.

Sensor Holder Style:

The sensor of the F12 can be mounted in a variety of ways

  • Integral sensor is standard and contains the standard sensor holder integrated into the enclosure of the F12 out the bottom of the enclosure
  • Remote sensor holder with 6 foot cable provides a remote mount sensor in a pre-wired 6'cable, this cable length is fixed and cannot be changed
  • Remote Sensor holder with Junction box allows for a remote mount sensor at a max length of 100 feet.  Standard option includes 100 feet of cable, if shorter cable length is preffered custom lengths can be provided.
  • Duct mount sensor holder provides a duct mount sensor for duct, or pipe mount application and a duct mount adapter.  Also includes 25 feet of cable for remote mounting ability.
  • Heated sensors are optional - please contact us to configure as they are very customizable.

Digital Output:

  • Standard 4-20 mA output is provided with all sensors
  • HART interface is available for all sensors
  • Modbus interface is only available for RS-485 sensors, and 115-230 VAC sensors. 

 

F12 Features:

Interchangeable Sensors: Every transmitter will accept up to 45 different sensor modules, greatly reducing the need for multiple transmitter models.

Sensor Auto-Test: Gas generators permanently installed on the sensor verify sensor operation by providing a “bump test” of the sensor from daily to once a week.

Smart Sensor Modules: Plug-in sensors store calibration data, allowing sensors to be calibrated separately from the transmitter. This allows bench calibration (or factory calibration) of sensors to reduce the necessity for carrying calibration gas around the plant.

Alarm & Relay Option: A non-IS version of the transmitter provides 3 integral alarm relays. Relays are programmable for set point, hysteresis, on-delay, off-delay, and other variables. Systems with alarms are available for operation from 12-30 VDC supplies or from 115-230 VAC power.

Serial Communication Interface: The IS version of the transmitter is available with HART™ communications. The HART protocol supports the HART Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The non-IS versions of the transmitter are available with MODBUS™ communications. The MODBUS protocol supports 9600 baud access to concentration and status information, and supports alarm setup and many other functions.

LCD Graphics Display: Gas Concentrations are displayed in large, easy to read numbers. The display also provides alarm indication and complete menus for setting up operating parameters.

Internal Data Logger: Measured gas values are stored at user definable intervals and can be recalled when needed on the LCD display. Data can be downloaded using a HART™ or MODBUS™ interface.

Sensor Calibration History: Each time a sensor is zeroed or calibrated, the data is stored in memory. Calibration history can be recalled and sensor condition reviewed by operating personnel whenever necessary.

Non-Intrusive Operation: Operating functions such as calibration, alarm setup, alarm reset, data view, and setup options are all available using sealed front panel switches on the face of the Nema 4X transmitter enclosure.

Heated Sensor Option: For use in applications where condensation is a problem, this heater option keeps the sensor above the dew point to eliminate loss of sensitivity due to moisture blockage on the sensor face.

Output Simulation: Transmitter analog output can be set to user definable values and relay outputs can be set to specific states for complete simulation of detection system operation. Output and alarms may also be inhibited for maintenance and calibration.

 

Click HERE to add additional gas sensors to your order.

 

F12 Accessories:

Calibration Adapter: The F12 can be calibrated by performing a zero calibration, and then the calibration adapter is required.

Flowcell Assembly: Allows the F12 to measure a sample gas flowing past the sensor. Sealed flowcell assembly is safe to use and provides accurate gas measurement of sample gas. Use in sample stream with a sample pump or sampler (example: A21 Gas Sampler)

Sensor Module Keeper: Can hold up to 4 sensors and keeps them ready for operation so complete sensor changes and sensor warm-up can be made in less than 1 minute.

Duct Sensor Adapter: Allows the sensors to be held in this adapter, and then secured to a duct or pipe. It has a 1 1/2" MNPT connection.

Panel Mount Bracket: Can be used to panel mount the F12. NOTE: this comes with the standard F12.

RAP-1: Alarm panel that offers visual and audible alarms to indicate gas levels that are unsafe.

RAP-2: Alarm panel that offers visual and audible alarms to indicate when Ozone levels are unsafe.

 

Wireless Monitoring & Data Logging Kit:

Use the Wireless Monitoring & Data logging Kit with your fixed mount monitor to connect it to the internet allowing access from anywhere. Receive Instant notifications with free text and email alerts. This is a great addition for your fixed mount gas detector.

 

Use this kit to connect your Fixed mount gas detector to the internet allowing remote access from anywhere.

 

F12 Specifications:

Sensor Type Electrochemical Cell
Range User adjustable within limits of selected sensor
Response Time Sensor dependent
Accuracy Generally ±10% of value, but limited by available calibration gas accuracy.
Repeatability  ±1% (Electronic)
Linearity  ±0.5% (Electronic)
Zero Drift Less than 2% full scale per month
Span Drift Dependent on operating environment but generally less than 3% per month
Analog Output 4-20 mA, 600 ohms max. at 24 VDC
Power Requirements          (Standard and HART™ Option) Powered from 4-20mA loop, 12-30 VDC, 25 mA max.
(Modbus Option) Requires regulated 10-28 VDC to power RS232/485. May be same supply as 4-20mA loop if not connected to loop receiver.
Alarm Relay Board  Option Powers transmitter, relays, and RS232/485 port; Requires Deep Case Three SPST relays (two with N/O contacts, one with N/C contacts) Each relay: 5A @ 230 VAC resistive; 5A @ 30 VDC resistive Coils are programmable as normally energized or normally de-energized
Additional Power Requirements AC version powered from 115/230 VAC, 1W nominal
DC version powered from 12-30VDC, 1W nominal
Enclosure NEMA 4X, polycarbonate with stainless steel hardware. Weatherproof and corrosion resistant (Standard) HWD: 4.4”(112mm) x 4.4” (112mm) x 3.5” (89mm), (w/Optional ) HWD: 4.9”(124mm) x 4.9” (124mm) x 5.5” (139mm)
Display Graphics LCD, 96w x 32h, backlit, transflective
Controls Four, dome-type push buttons; Remote alarm reset input (w/optional alarm relays only)

 

 

Product Sensor Range Integrated Relays Unit Features Price
F12-is Integrated Sensor
F12-is Integrated Sensor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

No

- Intrinsically Safe

- Integral sensor holder

- Loop powered 4-20 mA output

As low as $1,462.00
F12-is Remote Sensor
F12-is Remote Sensor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

No

- Intrinsically Safe

- Remote sensor with 6-foot sensor cable

- Loop powered 4-20 mA output

As low as $1,621.00
F12-D Integrated Sensor
F12-D Integrated Sensor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Yes

- Integral sensor holder
- 3-relay outputs (use settable)
- 12-30 VDC Power
- 4-20 mA output

As low as $1,743.00
F12-D Integrated Sensor
F12-D Integrated Sensor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Yes

- Integral sensor holder
- 3-relay outputs (use settable)
- 120/220 VAC Power
- 4-20 mA output

As low as $1,767.00
F12-D Remote Sensor 6ft
F12-D Remote Sensor 6ft

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Yes

- Remote sensor with 6-foot sensor cable

- 3-relay outputs (use settable)

- 120/220 VAC Electrical Power

As low as $1,853.00
F12-D Remote Sensor jct box
F12-D Remote Sensor jct box

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Yes

- Remote sensor (up to 100 feet)

- 3-relay outputs (use settable)

- 120/220 VAC Electrical Power

As low as $1,831.00
F12-is Integrated Sensor

F12-is Integrated Sensor

As low as $1,462.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

No

Unit Features

- Intrinsically Safe

- Integral sensor holder

- Loop powered 4-20 mA output

View Details
F12-is Remote Sensor

F12-is Remote Sensor

As low as $1,621.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

No

Unit Features

- Intrinsically Safe

- Remote sensor with 6-foot sensor cable

- Loop powered 4-20 mA output

View Details
F12-D Integrated Sensor

F12-D Integrated Sensor

As low as $1,743.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

Yes

Unit Features

- Integral sensor holder
- 3-relay outputs (use settable)
- 12-30 VDC Power
- 4-20 mA output

View Details
F12-D Integrated Sensor

F12-D Integrated Sensor

As low as $1,767.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

Yes

Unit Features

- Integral sensor holder
- 3-relay outputs (use settable)
- 120/220 VAC Power
- 4-20 mA output

View Details
F12-D Remote Sensor 6ft

F12-D Remote Sensor 6ft

As low as $1,853.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

Yes

Unit Features

- Remote sensor with 6-foot sensor cable

- 3-relay outputs (use settable)

- 120/220 VAC Electrical Power

View Details
F12-D Remote Sensor jct box

F12-D Remote Sensor jct box

As low as $1,831.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Integrated Relays

Yes

Unit Features

- Remote sensor (up to 100 feet)

- 3-relay outputs (use settable)

- 120/220 VAC Electrical Power

View Details

Product Sensor Range Unit Features Price
Configurable F12-D Gas Monitor
Configurable F12-D Gas Monitor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

 

-3 Built-In Relays (user settable)

- Configurable options 

- 120/220 VAC or 12-30VDC

As low as $1,453.00
Configurable F12-is Ozone Monitor
Configurable F12-is Ozone Monitor

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

- Intrinsically Safe 

- Configurable options 

- 12-30 VDC Power

As low as $1,315.00
Configurable F12-D Gas Monitor

Configurable F12-D Gas Monitor

As low as $1,453.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

 

Unit Features

-3 Built-In Relays (user settable)

- Configurable options 

- 120/220 VAC or 12-30VDC

View Details
Configurable F12-is Ozone Monitor

Configurable F12-is Ozone Monitor

As low as $1,315.00

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Unit Features

- Intrinsically Safe 

- Configurable options 

- 12-30 VDC Power

View Details

 

Downloads:

     F12 Product Spec Sheet

     F12D Product Manual

     F12 Support Drawings

 

 

Links to more info:

     Calibration information

     ATI Specific Calibration Information

 

 

Sensors:

We provide each sensor with a standard detection range.  However, for specific applications each sensor can be calibrated to custom ranges.  See list below for min, and max range options for each sensor, along with standard range.

Please contact us with any questions on what sensor might be right for you, or if other sensors are available for your application.

 

View a list of the F12 accessories.

More Information

Manufacturer ATI
Gas Acid Gases, Acetic Acid, Acteylene (C2H2), Alcohol, Ammonia (NH3), Arsine (AsH3), Bromine (Br2), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Diborane (B2H6), Dimethylamine, Ethylene Oxide (ETO), Fluorine (F2), Formaldehyde (CH2O), Germane (GeH4), Hydrocarbon (HC), Hydrogen (H2), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF), Hydrogen Peroxide (H2O2), Hydrogen Selenide (H2Se), Hydrogen Sulfide (H2S), Iodine (I2), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NOx), Oxygen (O2), Ozone (O3), Peracetic Acid, Phosgene (COCl2), Phosphine (PH3), Silane (SiH4), Sulfur Dioxide (SO2)
4-20 mA Output Yes
Relays 2 Relays
Field Replaceable Sensor Yes
Auto Test Generator None
Min, Max, Avg No
Voltage Output None
Power Requirements 12-30 VDC, 120 VAC or 220 VAC 50/60 hz. please specify desired voltage when ordering
Datalogging No
Rechargeable No
Field Replaceable Battery Yes
Warranty 1 Year
Audible Alarm No
Calibration 6 Months
Sensor Life 2 Years
Unit Features

- Remote sensor (up to 100 feet)

- 3-relay outputs (use settable)

- 120/220 VAC Electrical Power

Sensor Range

0-1,000 ppb

0-2 ppm

0-20 ppm

0-1,000 ppm

Resolution Range Dependent
Integrated Relays Yes
Press to skip carousel

We found other products you might like!

D12 XP Rated Gas Sensor
As low as $1,823.00
F12 Toxic Gas Sensor
As low as $1,453.00
F12-D Gas Monitor with Sensor Holder & 6ft Cable
As low as $1,853.00
F12-D Gas Monitor with Integral Sensor Holder
As low as $1,767.00
F12-D Integrated Sensor
As low as $1,743.00
Disabled