Aeroqual Perchloroethylene (C2Cl4) Sensor Head 0-200 ppm (PE)

The Perchloroethelyne (PERC) Sensor Head uses Gas Sensitive Semiconductor (GSS) technology to detect Perchloroethelyne from 0-200 ppm with 1.0 ppm resolution at up to +/- 5 ppm accuracy.

Perchloroethylene Information

$516.00
1 In Stock

This Perchloroethelyne (PERC) Sensor Head uses Gas Sensitive Semiconductor (GSS) technology to detect Perchloroethelyne from 0-200 ppm at 1 ppm resolution with <±5 ppm accuracy (in concentrations from 0 - 50 ppm) or  <± 10% accuracy (in concentrations from 50 - 200 ppm) 

This sensor uses an active sensor technology with an internal fan to pull air across the GSS sensor at a specific flow rate for accurate gas detection. 

This sensor head will be a direct fit onto any Series-200, Series-300, or Series-500 Aeroqual ozone monitor.  This head can be purchased as an addition to your existing monitor, or with a new base unit.  To purchase with a base unit see our Aeroqual ozone monitor page.  If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor.  The Series-200, Series-300, or Series-500 will automatically detect this as a 0-200 ppm PERC head and react accordingly.

 

Downloads:

Tech specs on Perc Sensor

MSDS for Perchloroethylene

Perchloroethylene sensor with Series-200 monitor

Perchloroethylene sensor with Series-300, 500 monitor

OSHA and Perchloroethylene regulations

EU Perchloroethyele regulations

 

 

Compare the Series 200, 300, 500 monitors:

Compare the Aeroqual handheld devices

Series-200

Aeroqual Series-200

Series-300

Aeroqual Series-300

Series-500

Aeroqual S-500

Interchangeable sensor head Yes Yes Yes
Digital LCD Display Yes Yes Yes
Min, Max, Average readings on screen Yes Yes Yes
Field Replaceable Battery Yes Yes Yes
Remote Sensor Capability Yes Yes Yes
Temp and HR Sensor optional Yes Yes Yes
External Control Outputs No Yes Yes
Audible Alarm No Yes Yes
High and Low Alarms No Yes Yes
0-5 VDC Analog output No Yes Yes
Zero Calibration capability Yes Yes Yes
Span Calibration capability No Yes Yes
Internal Data Logging Capability No No Yes

PC connection cables and capability

No No

Yes

 View a brochure with specifications on the Series-200, 300, and 500.

 

Detailed Sensor Specifications for Aeroqual ambient sensors

Aeroqual handheld sensor specificationsClick on image to expand

Sensor Type

There are two types of Aeroqual sensors, type 1 and type 2. 
The type 1 is used with the S-200, S-300, S-500, and S-900 monitors. 
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930

Aeroqual type-1 and type-2 sensors types

 

Full list of technical information and specifications for all Aeroqual sensors

Perchloroethylene Information

More Information
Manufacturer Aeroqual
Quickbooks Stock Level 1.000000
Call For Price No
Gas Perc (C2Cl4)
Sensor Type GSS (Gas Sensitive Semiconductor)
Range 0-200 ppm
Maximum Exposure 250 ppm
Monitor sensor fits S-200 / S-300 / S-500, Series-900
Minimum Detection Limit 1 ppm
Accuracy < +/- 5 ppm from 0-50 ppm; < +/- 10% from 50-200 ppm
Resolution 1 ppm
Response Time <5 s (T50)
Sampling Method Fan
Operational Temperature Range 0 to 40 C
Operational RH Range 10 to 90%
Warranty 6 Month
Write Your Own Review
You're reviewing:Aeroqual Perchloroethylene (C2Cl4) Sensor Head 0-200 ppm (PE)
Your Rating
Loading...