K-2513 Chlorine

Dissolved Chlorine Testing Kit - Measure chlorine 0-5.00ppm

*Use with the I-2001*

Chlorine Information

$30.00

The K-2513 is a kit that contains the pieces needed to perform 30 tests of chlorine level.  K-2513 Vacu-vials are used with the I-2001 Chlorine Meter which gives the digital readout of the ppm (mg/L) of chlorine.  The K-2513 comes in a nice box that can easily be stored in the carrying case for the I-2001.

The cost per test is only $1.02.

The I-2001 Dissolved Chlorine Meter is designed for accurately and quickly measuring chlorine in water levels from 0 - 5.00 ppm.  This device uses the DPD Method for testing.  Using this method free chlorine oxidizes DPD (N,N-diethyl-p-phenylenediamine) to form a pink colored species in direct proportion to the chlorine concentration. Other halogens, ozone and halogenating agents will produce high test results. Chlorine at concentrations significantly above the test range may prevent proper color development causing low test results.  The results are then displayed on the monitor in ppm (mg/L) of chlorine present.

What's included:

  • K-7513 Chlorine Vacu-vials (30 test)
  • A-2500 Activator Solution
  • Ampoule blank
  • 25 mL sample cup
  • Instruction manual

 

How to use the I-2001 and K-2513:

  1. The I-2001 must be turned on.
  2. Put the Zero ampoule into the device and cover with the light shield piece to zero out the unit. (NOTE: This must be zeroed any time the unit is turned off and turned back on)
  3. Add 5 drops of A-2500 activator solution to the empty sample cup.Add A-7400 activator solution to the sample cup
  4. Fill to the 25 mL mark in the sample cup with your water.Fill the sample cup to 25ml
  5. Snap the end of the Vacu-vial in the water on the bottom/side of the 25 mL sample cup.Snap the tip of the ampoule on the bottom and side of the sample cup
  6. Mix the contents of the ampoule by tipping back and forth a few times.Tip the vacu-vial back and forth to mix
  7. Dry the vacu-vial and wait 1 minute for color development.Dry vacu-vial and then insert into the I-2019
  8. Place the vacu-vial ampoule into the device (flat end first) for readout.

Downloads:

I-2001 Instructions

K-2513/K-2523 Instructions

Chlorine Information

More Information
Manufacturer CHEMetrics
Call For Price No
Gas Chlorine (Cl2)
4-20 mA Output No
Voltage Output None
Power Requirements 4 AAA Batteries
Datalogging No
Warranty 1 Year
Write Your Own Review
You're reviewing:K-2513 Chlorine
Your Rating
We found other products you might like!
Loading...