Aeroqual Carbon Dioxide (CO2) Sensor Head 0-2000 ppm (CD)

Carbon Dioxide (CO2) sensor head. Non-dispersive Infra-red (NDIR) head will measure CO2 from 0-2000 ppm with a 1 ppm resolution providing an accuracy of <± 5% of reading.

Carbon Dioxide Information

2 In Stock
SKU
AQ CD
  $790.00

Description / Aeroqual Carbon Dioxide (CO2) Sensor Head 0-2000 ppm (CD)

Carbon Dioxide (CO2) sensor head whose Non-dispersive Infra-red (NDIR) sensor will measure CO2 from 0-2000 ppm with a 1 ppm resolution providing an accuracy of <± 5% of reading.

This head uses an active sensor technology with an internal fan to pull air across the NDIR sensor at a specific flow rate for accurate gas detection. This fan will pull a fresh gas stream across the NDIR sensor every 120 seconds for accurate CO2 detection.

This sensor head will be a direct fit onto any Ranger, Series-300, or Series-500 Aeroqual ozone monitor.  This head can be purchased as an addition to your existing monitor, or with a new base unit.  To purchase with a base unit see our Aeroqual ozone monitor page.  If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor.  The Ranger, Series-300, or Series-500 will automatically detect this as a 0-2000 ppm NDIR Carbon Dioxide head and react accordingly.

 

Compare the Series 300, 500, and Ranger monitors:

Compare the Aeroqual handheld devices

Series-300

 

Aeroqual Series-300

Series-500

 

Aeroqual Series-300

Ranger

 

Interchangeable sensor head Yes Yes Yes
Digital LCD Display Yes Yes Yes
Min, Max, Average readings on screen Yes Yes Yes
Field Replaceable Battery Yes Yes Yes
Remote Sensor Capability Yes Yes Yes
Temp and HR Sensor optional Yes Yes Yes
External Control Outputs Yes Yes Yes
Audible Alarm Yes Yes Yes
High and Low Alarms Yes Yes Yes
0-5 VDC Analog output Yes Yes Yes
Zero Calibration capability Yes Yes Yes
Span Calibration capability Yes Yes Yes
Internal Data Logging Capability No Yes Yes

PC connection cables and capability

No Yes

Yes

Built in wi-fi connection

No No

Yes

Hot-Swap Service

No No

Yes

 

 

 View a brochure with specifications on the Series-300, and 500 and Ranger.

 

 

Detailed Sensor Specifications for Aeroqual ambient sensors

Aeroqual handheld sensor specificationsClick on image to expand

Sensor Type

There are two types of Aeroqual sensors, type 1 and type 2. 
The type 1 is used with the S-200, S-300, S-500, and S-900 monitors. 
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930

Aeroqual type-1 and type-2 sensors types

 

Full list of technical information and specifications for all Aeroqual sensors

Carbon Dioxide Information

 

 

All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures. 

**Calibration Service Request Form **

Calibration Costs:

Calibration costs do vary, see below to get an estimate: 

Calibration Fee: $150

Analyzer Calibration Fee: $300

PM Calibration Sensor Fee: $330

Genie Calibration Fee: $265

ATI Calibration Fee: $205

** note that prices are subject to change per labor and parts required.

More Information

Manufacturer Aeroqual
Quickbooks Stock Level 2.000000
Quickbooks Stock Date Expected 2024-11-11 00:00:00
Gas Carbon Dioxide (CO2)
Sensor Type NDIR (Non-dispersive Infra-red)
Range 0-2000 ppm
Maximum Exposure 2000 ppm
Monitor sensor fits S-200 / S-300 / S-500, Series-900
Minimum Detection Limit 2
Accuracy < +/- 5% of reading
Resolution 1 ppm
Response Time <60 s
Sampling Method Fan
Operational Temperature Range 0 to 40 C
Operational RH Range 10 to 90%
Warranty 6 Month

We found other products you might like!

Navigating through the elements of the carousel is possible using the tab key. You can skip the carousel or go straight to carousel navigation using the skip links.