Aeroqual Hydrogen Sulfide (H2S) Sensor Head 0-100 ppm (EHT)
- SKU
- AQ EHT
Description / Aeroqual Hydrogen Sulfide (H2S) Sensor Head 0-100 ppm (EHT)
Hydrogen Sulfide (H2S) Head uses Gas Sensitive Electrochemical (GSE) technology to detect H2S gas from 0-100 ppm at 0.1 ppm resolution with <±0.5 ppm accuracy (in concentrations from 0 - 5 ppm) or <± 10% accuracy (in concentrations from 5 -100 ppm)
This head uses an active sensor technology with an internal fan to pull air across the GSE sensor at a specific flow rate for accurate gas detection. The fan pulls a stream of air past the sensor every 30 seconds providing a new reading of H2S levels and a 60-second response time.
This sensor head will be a direct fit onto any Series-200, Series-300, or Series-500 Aeroqual ozone monitor. This head can be purchased as an addition to your existing monitor, or with a new base unit. To purchase with a base unit see our Aeroqual ozone monitor page. If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor. The Series-200, Series-300, or Series-500 will automatically detect this as a 0-100 ppm H2S head and react accordingly.
View a brochure with specifications on the Series-200, 300, and 500.
Detailed Sensor Specifications for Aeroqual ambient sensors
Sensor Type
There are two types of Aeroqual sensors, type 1 and type 2.
The type 1 is used with the S-200, S-300, S-500, and S-900 monitors.
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930
Full list of technical information and specifications for all Aeroqual sensors
More Information
Manufacturer | Aeroqual |
---|---|
Quickbooks Stock Level | 1.000000 |
Call For Price | No |
Gas | Hydrogen Sulfide (H2S) |
Sensor Type | GSE (Gas Sensitive Electrochemical) |
Range | 0-100 ppm |
Maximum Exposure | 200 ppm |
Monitor sensor fits | S-200 / S-300 / S-500, Series-900 |
Minimum Detection Limit | 0.2 ppm |
Accuracy | < +/- 0.5 ppm from 0-5 ppm; < +/- 10% from 5-100 ppm |
Resolution | 0.1 ppm |
Response Time | <60 s |
Sampling Method | Fan |
Operational Temperature Range | 0 to 40 C |
Operational RH Range | 10 to 90% |
Warranty | 6 Month |