Aeroqual Carbon Dioxide (CO2) Sensor Head 0-2000 ppm (CD)

Aeroqual Carbon Dioxide (CO2) Sensor Head 0-2000 ppm (CD)

Carbon Dioxide (CO2) sensor head. Non-dispersive Infra-red (NDIR) head will measure CO2 from 0-2000 ppm with a 1 ppm resolution providing an accuracy of <± 5% of reading.

Carbon Dioxide Information

SKU
AQ CD
$815.00

Description / Aeroqual Carbon Dioxide (CO2) Sensor Head 0-2000 ppm (CD)

Carbon Dioxide (CO2) sensor head whose Non-dispersive Infra-red (NDIR) sensor will measure CO2 from 0-2000 ppm with a 1 ppm resolution providing an accuracy of < ± 10 ppm + 5% of reading.

This head uses an active sensor technology with an internal fan to pull air across the NDIR sensor at a specific flow rate for accurate gas detection. This fan will pull a fresh gas stream across the NDIR sensor every 120 seconds for accurate CO2 detection.

 

Full list of technical information and specifications for all Aeroqual sensors

Carbon Dioxide Information

Full list of Aeroqual Products

 

This sensor head will be a direct fit onto any Series-200, Series-300, Series-500 or Ranger Aeroqual ozone monitor.  This head can be purchased as an addition to your existing monitor, or with a new base unit.  To purchase with a base unit see our Aeroqual ozone monitor page.  If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor.  

 

 

Compare the Series 300 and 500, Aeroqual Ranger monitors:

Compare the Aeroqual handheld devices

Series-300

Aeroqual Series-300

Series-500

Aeroqual S-500

Aeroqual Ranger

Interchangeable sensor head Yes Yes Yes
Digital LCD Display Yes Yes Yes
Min, Max, Average readings on screen Yes Yes Yes
Field Replaceable Battery Yes Yes Yes
Remote Sensor Capability Yes Yes Yes
Temp and HR Sensor optional Yes Yes Yes
External Control Outputs Yes Yes Yes
Audible Alarm Yes Yes Yes
High and Low Alarms Yes Yes Yes
0-5 VDC Analog output Yes Yes Yes
Zero Calibration capability Yes Yes Yes
Span Calibration capability Yes Yes Yes
Internal Data Logging Capability No Yes Yes

PC connection cables and capability

No Yes

Yes

Built in wi-fi connection

No No

Yes

Hot-Swap Service 

Yes Yes

Yes

 

 

Detailed Sensor Specifications for Aeroqual ambient sensors

Click on image to expand

 

Calibration:

This sensor is a Non-dispersive Infra-red (NDIR) sensor. The Aeroqual AQ CD sensor has a detection range of 0-2000 ppm, so the calibration gas you use must fall within this range. Refer to the table below for our recommended calibration gas options.

Product Range Price
Carbon Dioxide Calibration Gas
Carbon Dioxide Calibration Gas
Multiple Ranges
$208.00
Carbon Dioxide Calibration Gas - 1,000 ppm
Carbon Dioxide Calibration Gas - 1,000 ppm
1000 ppm
$204.00
Carbon Dioxide Calibration Kit
Carbon Dioxide Calibration Kit
5000 ppm, 5.0%
$445.00
Carbon Dioxide Calibration Kit - 103L
Carbon Dioxide Calibration Kit - 103L
1000 ppm
$825.00
Carbon Dioxide Calibration Gas

Carbon Dioxide Calibration Gas

$208.00

Range

Multiple Ranges
View Details
Carbon Dioxide Calibration Gas - 1,000 ppm

Carbon Dioxide Calibration Gas - 1,000 ppm

$204.00

Range

1000 ppm
View Details
Carbon Dioxide Calibration Kit

Carbon Dioxide Calibration Kit

$445.00

Range

5000 ppm, 5.0%
View Details
Carbon Dioxide Calibration Kit - 103L

Carbon Dioxide Calibration Kit - 103L

$825.00

Range

1000 ppm
View Details

 

 

Sensor Type:

There are two types of Aeroqual sensors, type 1 and type 2. 
The type 1 is used with the S-200, S-300, S-500, Ranger and S-900 monitors.
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930

Aeroqual type-1 and type-2 sensors types

 

 

Full list of technical information and specifications for all Aeroqual sensors

Carbon Dioxide Information

 

All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures. 

**Calibration Service Request Form **

Calibration Costs:

Calibration costs do vary, see below to get an estimate: 

- In-house Calibration Fee (most electrochemical and HMOS base sensors): $150

  • - UV Analyzer Calibration Fee (2B Tech 106 Series Analyzers requires a $192.50 service kit for annual calibration) : $300
  •  
  • - 2B Technologies 306 Calibration Fee: $1200
  •  
  • - Genie Calibration Fee: $265
  •  
  • - Aeroqual PM Sensor HotSwap/Calibration Fee: $550
  •  
  • - ATI (H2O2 and PAA sensor) Calibration Fee: $205
  •  

** note that prices are subject to change per labor and parts required.

More Information

Manufacturer Aeroqual
Gas Carbon Dioxide (CO2)
Sensor Type NDIR (Non-dispersive Infra-red)
Range 0-2000 ppm
Maximum Exposure 2000 ppm
Monitor sensor fits S-200 / S-300 / S-500, Series-900, Series-930, Ranger
Minimum Detection Limit 10 ppm
Accuracy < ± 10 ppm + 5%
Resolution 1 ppm
Response Time 120 Seconds
Sampling Method Fan
Operational Temperature Range 0 to 40°C
Operational RH Range 10 to 95%