Search Results
Loading your search results
We couldn't find what you were looking for, however, we have more than 4000 products. Check out some of the options below!
What Gas Do You Want To Monitor?
Shop By Brand

UV Analzyers
Our fixed-mount and wall-mount monitors and detectors provide a range of functionality, from basic display and alarms to full-featured systems that provide displays, alarms, datalogging, and control-grade outputs. We offer fixed mount monitors from the following manufacturers:
Follow this link to search without the table HERE:
- Board-level mounting - Accuracy = 1.5ppb or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Benchmount Enclosure - Accuracy = 2% of reading - Low power draw; can be battery-operated (12 VDC) - Integrated datalogging - Benchmount Enclosure - Accuracy = 1.5 ppb or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - FEM: EQOA-0914-218 -Benchmount enclosure -Accuracy = 1.5 ppb or 2% of reading - DewLine™ for Humidity Control - SD Card for portable data storage - FEM: EQOA-0410-190 - Benchmount Enclosure - Accuracy = 1.0 ppb or 2% of reading - Dual beam optical bench - SD Card for portable data storage - DewLine™ for Humidity Control - FEM: EQOA-0410-190 - Industrial Enclosure, Water Resistant - Accuracy = 1.5 ppb or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Minimal zero drift - Multi-channel options available Customizable: 0-500 ppm Unit Features - Board-level mounting - Accuracy = 1.5ppb or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 2% of reading - Low power draw; can be battery-operated (12 VDC) - Integrated datalogging Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 1.5 ppb or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - FEM: EQOA-0914-218 Range Resolution Unit Features -Benchmount enclosure -Accuracy = 1.5 ppb or 2% of reading - DewLine™ for Humidity Control - SD Card for portable data storage - FEM: EQOA-0410-190 Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 1.0 ppb or 2% of reading - Dual beam optical bench - SD Card for portable data storage - DewLine™ for Humidity Control - FEM: EQOA-0410-190 Range Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 1.5 ppb or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Minimal zero drift - Multi-channel options available Range Customizable: 0-500 ppm Resolution
Product
Unit Features
Range
Resolution
Price
0-20 ppm
0.1 ppb
0-999 ppm
0.01 ppm
Call For Price
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
0-20 ppm
0.1 ppb
1 ppb
UV-106L OEM
UV-100
UV-106-L
Model 202
Model 205
UV-106L-NEMA
465L
- Board-level mounting - Accuracy = 0.01 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Benchmount Enclosure - Accuracy = 0.01 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - Board-level mounting - Accuracy = 0.1 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Benchmount Enclosure - Accuracy = 0.05 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control - Industrial Enclosure, Water Resistant - Accuracy = 0.05 ppm or 2% of reading - Multi-Channel options avaialble - DewLine™ for Humidity Control - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Customizable ranges for suburb acuracy - Minimal zero drift - Multi-channel options available Customizable: 0-10,000 ppm 0-3 wt% - Industrial Enclosure, Water Resistant - Accuracy = 0.01 ppm or 2% of reading - Multi-Channel options available - DewLine™ for Humidity Control Unit Features - Board-level mounting - Accuracy = 0.01 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 0.01 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features - Board-level mounting - Accuracy = 0.1 ppm or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 0.05 ppm or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.05 ppm or 2% of reading - Multi-Channel options avaialble - DewLine™ for Humidity Control Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Customizable ranges for suburb acuracy - Minimal zero drift - Multi-channel options available Range Customizable: 0-10,000 ppm 0-3 wt% Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.01 ppm or 2% of reading - Multi-Channel options available - DewLine™ for Humidity Control Range Resolution
Product
Unit Features
Range
Resolution
Price
0-1,000 ppm
0.01 ppm
0-1,000 ppm
0.01 ppm
0-10,000 ppm
0.1 ppm
0-10,000 ppm
0.1 ppm
0-10,000 ppm
0.1 ppm
0.001 ppm
0-1000 ppm
0.01 ppm
UV-106M OEM
UV-106-M
UV-106MH-OEM
UV-106-MH
UV-106MH-NEMA
465M
UV-106M-NEMA
- OEM Mounting, no display - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Minimal Zero drift - Low power draw (15 VDC) Customizable 0-25 wt% 0-500 g/m3 - Board-level mounting - Accuracy = 0.01 wt% or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface - Benchmount Enclosure - Accuracy = 0.01 wt% or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control -No Need for UV Filters -Temp. & Pressure Compensation -Analog & RS485/RS232 Outputs -0.5 to 5 LPM Flow - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Customizable ranges for supurb accuracy - Minimal zero drift - Multi-channel options available Customizable: 0-25 wt% 0-400 wt% - Industrial Enclosure, Water Resistant - Accuracy = 0.01 wt% or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Unit Features - OEM Mounting, no display - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Minimal Zero drift - Low power draw (15 VDC) Range Customizable 0-25 wt% 0-500 g/m3 Resolution Unit Features - Board-level mounting - Accuracy = 0.01 wt% or 2% of reading - Low power draw (12 VDC) - DewLine™ for Humidity Control - Integrated Display and interface Range Resolution Unit Features - Benchmount Enclosure - Accuracy = 0.01 wt% or 2% of reading - Low power draw; can be battery-operated (12 VDC) - DewLine™ for Humidity Control Range Resolution Unit Features -No Need for UV Filters -Temp. & Pressure Compensation -Analog & RS485/RS232 Outputs -0.5 to 5 LPM Flow Range Resolution Unit Features - Rack-Mount or NEMA-4X Configurations - Accuracy = ±1% of full scale - Repeatabality = ±0.5% of full scale - Rugged design, simple maintenance - Customizable ranges for supurb accuracy - Minimal zero drift - Multi-channel options available Range Customizable: 0-25 wt% 0-400 wt% Resolution Unit Features - Industrial Enclosure, Water Resistant - Accuracy = 0.01 wt% or 2% of reading - Multi-channel options available - DewLine™ for Humidity Control Range Resolution
Product
Unit Features
Range
Resolution
Price
0.01 %
0-20 wt%
0.01 %
0-20 wt%
0.01 %
0 - 5, 0 - 10, 0 - 15, 0 - 20% w/w, 0 - 25% w/w; 0 - 25, 0 - 100, 200, 300, 400 g/Nm3
0.01 %
0.01 %
0-20 wt%
0.01 %
Model 452
UV-106-H OEM
UV-106-H
454 Ozone Analyzer
465H
UV-106H-NEMA
-Calibrate Any Ozone Monitor -Autocalibration Scheduler -Easy-To-Use Menu Unit Features -Calibrate Any Ozone Monitor -Autocalibration Scheduler -Easy-To-Use Menu Range Resolution
Product
Unit Features
Range
Resolution
Price
30-1000 ppbv
2 ppbv
Model 306 Ozone Calibration Source
- Interference free measurement of dissolved ozone in ultrapure or "dirty" water - NEMA water-proof housing - Records measurement every 10 seconds - Internal data logger logs 16,383 lines of data - Precision and accuracy of 0.05 ppm or 1% of reading - Both serial and user-scalable analog outputs (0-2.5V and 4-20mA) - Selectable data averaging times of 10 seconds, 1 minute, 5 minutes, and 1 hour Unit Features - Interference free measurement of dissolved ozone in ultrapure or "dirty" water - NEMA water-proof housing - Records measurement every 10 seconds - Internal data logger logs 16,383 lines of data - Precision and accuracy of 0.05 ppm or 1% of reading - Both serial and user-scalable analog outputs (0-2.5V and 4-20mA) - Selectable data averaging times of 10 seconds, 1 minute, 5 minutes, and 1 hour Range Resolution
Product
Unit Features
Range
Resolution
Price
0 - 100 ppm
0.1 ppm
Call For Price
UV-106-W Aqueous Ozone Monitor
Rental Period Rental Period
Product
Rental Period
Price
Weekly
Weekly
UV-106-L Ozone Analyzer Rental
UV-106-M Ozone Analyzer Rental










