Aeroqual Ozone (O3) Sensor Head 0-0.15 ppm (OZU)
The Aeroqual 0-0.15 ppm Ozone Sensor Head is designed to provide accurate, consistent readings of the ozone in your ambient airspace.
- SKU
- AQ OZU
Description / Aeroqual Ozone (O3) Sensor Head 0-0.15 ppm (OZU)
Ozone (O3) sensor head. Gas Sensitive Semiconductor (GSS) head will measure Ozone gas from 0-0.15 ppm with a 0.001 ppm resolution. This is the perfect head for measuring low levels of ozone up to 0.15 ppm. The OZU head will allow ozone gas measurements at very low levels, and a 0.001 ppm resolution without the expense of an expensive ozone analyzer.
This sensor uses an active sensor technology with an internal fan to pull air across the GSS sensor at a specific flow rate for accurate gas detection. This fan will pull a fresh gas stream across the GSS sensor every 60 seconds for accurate Ozone detection in most every environment.
This sensor head will be a direct fit onto any Ranger, Series-300, or Series-500 Aeroqual ozone monitor. This head can be purchased as an addition to your existing monitor, or with a new base unit. To purchase with a base unit see our Aeroqual ozone monitor page. If you currently have an Aeroqual ozone monitor this sensor will be a direct fit for your current monitor. The Ranger, Series-300, or Series-500 will automatically detect this as a 0-10 ppm Chlorine head and react accordingly.
Additional Information:
Detailed Sensor Specifications for Aeroqual ambient sensors:
Sensor Type:
There are two types of Aeroqual sensors, type 1 and type 2.
The type 1 is used with the S-200, S-300, S-500, and S-900 monitors.
The type 2 is calibrated specifically with fittings on the end allowing it to be used with the ENC enclosure and in the S930
Full list of technical information and specifications for all Aeroqual sensors
All sensors require a yearly calibration to ensure your gas measurements are accurate and performing within manufacturer standards. This page is desiccated to the individual manufacturers we represent and their specific calibration procedures.Â
**Calibration Service Request Form **
Calibration costs do vary, see below to get an estimate:Â Calibration Fee: $150 Analyzer Calibration Fee: $300 PM Calibration Sensor Fee: $330 Genie Calibration Fee: $265 ATI Calibration Fee: $205 ** note that prices are subject to change per labor and parts required. |
More Information
Manufacturer | Aeroqual |
---|---|
Quickbooks Stock Level | 3.000000 |
Quickbooks Stock Date Expected | 2024-11-11 00:00:00 |
Gas | Ozone (O3) |
Sensor Type | GSS (Gas Sensitive Semiconductor) |
Range | 0-0.15 ppm |
Maximum Exposure | 1.0 ppm |
Monitor sensor fits | S-200 / S-300 / S-500, Series-900 |
Minimum Detection Limit | 0.001 ppm |
Accuracy | < +/- 10 % |
Resolution | 0.001 ppm |
Response Time | <60 s |
Sampling Method | Fan |
Operational Temperature Range | 0 to 40 C |
Operational RH Range | 10 to 90% |
Warranty | 6 Month |