Ozone Monitors
Gas Dependent - over 15 Detectable Gases - Min, Max, and Avg Logged - Bluetooth Data Collection - HotSwap Sensor Program Gas Dependent - Over 15 Detectable Gases -Min., Max, Avg., Logged -Field Replaceable Sensor -0-5 VDC Output -Control and Alarm Relays -Integrated Datalogging Gas Dependent - Over 20 Detectable Gases - LED Screen - Password Managment - Self-adjustment function Gas Dependent - Over 15 Detectable Gases - Compact and lightweight design for easy handling and portability. - One-button operation for simple and intuitive use. - Durable and rugged construction for use in harsh environments. - Bluetooth connectivity for data transfer and remote monitoring. - Long battery life for extended use in the field. - Wide range of sensor options for detection of different gases, including hydrogen sulfide, carbon monoxide, oxygen, and more. 0-0.14 ppm -Low Cost -Audible Alarm -User Settable Relay -0-2.5 VDC Output Gas Dependent - Over 20 Detectable Gases -Internal Sample Pump -Fast Response Time -Carry Case w/ Accessories -Integrated Datalogging Gas Dependent - Custom Gases and Ranges Avalible - Gas pump sampling with high sensitivity - Easy operation - Compact design for easy carrying - High strength plastics and anti-slip rubber make this sensor high strength (water, dust and explosion-proof) - Compatible with computers for storing and printing data records Gas Dependent - Custom Gases and Ranges Avalible - Gas pump sampling with high sensitivity - Easy operation - Compact design for easy carrying - High strength plastics and anti-slip rubber make this sensor high strength (water, dust and explosion-proof) - Compatible with computers for storing and printing data records Gas Dependent - Custom Gases and Ranges Avalible - Sensor: Pumping sampling method and high-sensitivity sensor, with high sensitivity and repeatability. - 32-bit built-in MCU, high reliability and self-adaptation ability. - Alarms: Adjustable audio, visual, and vibration alarms alert when preset levels are reached. Alarm digital time stamp and logging. - High strength engineering plastics and compound anti-slippery rubber; high strength, water-proof, dust-proof and explosion-proof. 0.08-1.6 ppm-hr - Personal Monitoring - Simple Display - Easy to Use
Product
Audible Alarm
Sensor Range
Unit Features
Price
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Our fixed-mount and wall-mount monitors and detectors provide a range of functionality, from basic display and alarms to full-featured systems that provide displays, alarms, datalogging, and control-grade outputs. We offer fixed mount monitors from the following manufacturers:
Follow this link to search without the table HERE:
- OEM Configuration - Includes datalogging with software - Low power consumption; can be battery operated - Two level relay for control purposes - Long-life pump (15,000 hr) - Standard enclosure - Includes datalogging with software - Low power consumption; can be battery operated - Two level relay for control purposes - Long-life pump (15,000 hr) - Standard enclosure - Includes datalogging with software - Low power consumption; can be battery operated -15,000 Hr Pump Life -Two Level Relay Control -Standard enclosure -Includes datalogging with software -Measures accurate at low and high levels of ozone - Offers many options to customize - NEMA 4X Industrial wall mount enclosure - Mercury-free UV LED source - Built-in diagnostics/error logs/warning alarms - Minimal zero drift - Programmable concentration alarms - Temperature and pressure compensation (standard) - Ethernet standard, WiFi (coming soon)​ Call For Price - Standard Enclosure - Dual beam optical bench for faster response time - Eliminates Water Vapor Interference - Includes data logging with software -NEMA 4X Industrial wall mount enclosure - Built-in diagnostics/error logs/warning alarms - Minimal zero drift - Programmable concentration alarms - Temperature and pressure compensation (standard) - 1, 3 and 6 stream versions available for safety monitoring - NEMA 4X Industrial wall mount enclosure - USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure - Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units - Two Level Relay Control - Includes datalogging with software - 1, 3 and 6 stream verions available for safety monitoring
Product
Unit Features
Range
Resolution
Price
0-100 ppm
0.0001 ppm
0-900 ppm
0.01 ppm
0-100 ppm
0.0001 ppm
0-250 ppm
0.1 ppb
​0-1 ppm to 0-500 ppm
0.001 ppm
0-250 ppm
0.1 ppb
From 0-1 ppm to 0-500 ppm
0.001 ppm
0-0.1 ppb to 0-100 ppm
0-01%
- OEM Configuration - Includes datalogging with software - Low power consumption; can be battery operated - Two level relay for control purposes - Long-life pump (15,000 hr) - Standard enclosure - Includes datalogging with software - Low power consumption; can be battery operated -15,000 Hr Pump Life -Two Level Relay Control - OEM Configuration - Includes datalogging with software - Low power consumption; can be battery operated - Two level relay for control purposes - Long-life pump (15,000 hr) - Standard Configuration - Includes datalogging with software - Low power consumption; can be battery operated - Two level relay for control purposes - Long-life pump (15,000 hr) - NEMA 4X Industrial wall mount enclosure - USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure - Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units - Two Level Relay Control - Includes datalogging with software - 1, 3 and 6 stream verions available for safety monitoring Call For Price - NEMA 4X Industrial wall mount enclosure - Mercury-free UV LED source - Built-in diagnostics/error logs/warning alarms - Minimal zero drift - Programmable concentration alarms - Temperature and pressure compensation (standard) - Ethernet standard, WiFi (coming soon)​ Call For Price - NEMA 4X Industrial wall mount enclosure - Sample conditioning System for samoling from humid environments - Built-in diagnostics/error logs/warning alarms - Minimal zero drift - Programmable concentration alarms - Temperature and pressure compensation (standard) - 1, 3 and 6 stream versions available for safety monitoring - NEMA 4X Industrial wall mount enclosure - USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure - Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units - Two Level Relay Control - Includes datalogging with software - 1, 3 and 6 stream verions available for safety monitoring
Product
Unit Features
Range
Resolution
Price
0-1,000 ppm
0.01 ppm
0-1,000 ppm
0.01 ppm
0-10,000 ppm
0.1 ppm
0-10,000 ppm
0.1 ppm
0-20% by weight, or 0-14% by volume
0.01%
0-1,000 ppm to 0-10,000 ppm
0.001 ppm
0-1000 ppm to 0-10,000 ppm 0-5g/Nm3 to 0-50 g/Nm3 0-1% w/w to 0-3% w/w
0.001 ppm
0-1000 ppm
0.01 ppm
-Works in High Purity Applications -2 sec. to 95% Response Time -115 PSIA Proof Pressure -0.01% Resolution -On-Board Microprocessor -NEMA Enclosure Option -0.01% Resolution -On-Board Microprocessor -NEMA Enclosure Option -No Need for UV Filters -Temp. & Pressure Compensation -Analog & RS485/RS232 Outputs -0.5 to 5 LPM Flow - Intuitive graphical user interface - Mercury-free UV LED source - Built-in diagnostics/error logs/warning alarms - Modular internal design - Minimal zero drift - Programmable auto-zero function included - Programmable concentration alarms - Temperature and pressure compensation (standard) - Ethernet standard​, WiFi (coming soon) Call For Price - Low power consumption; can be battery operated - Internal data logger with real time clock - On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m, 5 m and 1 hr - USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure - Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units - Two level relay for control purposes (e.g., control of ozone source or turn warning light on and off) -Self Check Warning Alarms -Quick Response Times -UV Absorption Methods -Minimal Zero Drift
Product
Unit Features
Range
Resolution
Price
0–5, 0–10, 0–15, 0–20% w/w 0–100, 200, 300, 400 g/Nm3
0.01 %
0-20% by weight, in oxygen or air, 0-14% by volume
0.01 %
0-20% by weight, in oxygen or air, 0-14% by volume
0.01 %
0 - 5, 0 - 10, 0 - 15, 0 - 20% w/w, 0 - 25% w/w; 0 - 25, 0 - 100, 200, 300, 400 g/Nm3
0.01 %
0-100 g/Nm3 to 0-400 g/Nm3
0.01 %
0-20% by weight, or 0-14% by volume
0.01 %
0-5% w/w to 0-25% w/w 0-100g/Nm3 to 0-400g/Nm3
0.01 %
-Calibrate Any Ozone Monitor -Autocalibration Scheduler -Easy-To-Use Menu
Product
Unit Features
Range
Resolution
Price
30-1000 ppbv
2 ppbv
-Dual field programmable alarms -Quick Response Times -UV Absorption Methods -Minimal Zero Drift -Reliable, repeatable and accurate​ Call For Price - Interference free measurement of dissolved ozone in ultrapure or "dirty" water - NEMA water-proof housing - Records measurement every 10 seconds - Internal data logger logs 16,383 lines of data - Precision and accuracy of 0.05 ppm or 1% of reading - Both serial and user-scalable analog outputs (0-2.5V and 4-20mA) - Selectable data averaging times of 10 seconds, 1 minute, 5 minutes, and 1 hour
Product
Unit Features
Range
Resolution
Price
0-1, 0-2 mg/L
0.001 ppm
0 - 100 ppm
0.1 ppm
Call For Price
Product
Rental Period
Price
Weekly
Weekly
- Acid Gases
- Acetic Acid
- Acetone
- Acetylene
- Adenosine Triphosphate (ATP)
- Alcohol
- Alkalinity
- Ammonia
- Aromatic Isocyanates (TDI & MDI)
- Arsine
- Bacteria/APC
- Benzene
- Bromine
- Butane
- Carbohydrazide
- Carbon Dioxide
- Carbon Monoxide
- Chloride
- Chlorine
- Chlorine Dioxide
- Chromate
- COD
- Combustibles
- Copper
- Cyanide
- DEHA
- Detergents
- Diborane
- Dimethylamine
- E. Coli
- Ethylene Oxide
- Fluoride
- Fluorine
- Formaldehyde
- Germane
- Glutaraldehyde
- Glycol
- Hardness
- Hydrazine
- Hydride
- HydroCarbons
- Hydrogen
- Hydrogen Bromide
- Hydrogen Chloride
- Hydrogen Cyanide
- Hydrogen Fluoride
- Hydrogen Peroxide
- Hydrogen Selenide
- Hydrogen Sulfide
- Hypochlorite
- Iodine
- Iron
- Manganese
- Mercaptobenzothiazole
- Mercury
- Methane
- Molybdate
- Monochloramine
- Nitrate
- Nitric Oxide
- Nitrite
- Nitrogen Dioxide
- Nitrogen Oxides
- NMHC
- Oxygen
- Ozone
- Particulate Matter
- Peracetic Acid
- Perchloroethelyne
- pH
- Phenols
- Phosgene
- Phosphate
- Phosphine
- Silane
- Silica
- Sodium Persulfate
- Sulfate
- Sulfide
- Sulfite
- Sulfur Dioxide
- Thiosulfate
- Total Dissolved Solids (TDS)
- VOC
- Zinc